Detecting Structural Progression in Glaucoma with Optical Coherence Tomography
Open accessThe DOI matches its Crossref record.
Abstract
Optical coherence tomography (OCT) is increasingly used to obtain objective measurements of the retinal nerve fiber layer (RNFL), optic nerve head and macula for assessing glaucoma progression. Although OCT has been widely adopted in clinical practice, uncertainty remains concerning how it should be best utilized. Questions include: What is the best structure to measure? What quantity of change is significant? Are structural changes relevant to the patient? How are longitudinal measurements affected by aging, and how can changes due to aging be differentiated from true progression? How should OCT be used alongside visual fields, and how often should OCT be performed? Recent studies have addressed some of these questions. Important developments include appreciation of the need to use a consistent point of reference for structural measurements, leading to the introduction of Bruch’s membrane opening (BMO)–based measures including BMO-minimum rim width and BMO-minimum rim area. Commercially available OCT devices also permit analysis of macular changes over time, for example, changes in the ganglion cell and inner plexiform layers, the sites of the retinal ganglion cell bodies and dendrites, respectively. Several longitudinal studies have compared rates of change in RNFL and macular measurements, with some suggesting the relative value of each parameter may differ at different stages of disease. In early disease, looking for change over time may also be useful for glaucoma diagnosis, with advantages over classifying eyes using cross-sectional normative databases. Optimal glaucoma management requires information from imaging and visual fields and efforts have been made to combine information, reducing the noise inherent in both tests to benefit from their different performances according to the stage of the disease. Combining information from different structural measurement may also be useful. There is now substantial evidence that progressive structural changes are of direct clinical relevance, with progressive changes on OCT often preceding functional loss and patients with faster change on OCT at increased risk of worsening visual losses. Identification of such patients offers the possibility of commencing or escalating treatment at an earlier stage. This review appraises recent developments in the use of OCT for assessing glaucoma progression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Review of Deep Learning for Screening, Diagnosis, and Detection of Glaucoma Progression
Thompson, A. C., Jammal, A. A., & Medeiros, F. A. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.2.42 · Cited by 195
Self-citationDeep Learning and Glaucoma Specialists
Phene, S., Dunn, R. C., Hammel, N., Liu, Y., Krause, J., Kitade, N., Schaekermann, M., Sayres, R., Wu, D. J., Bora, A., et al. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2019.07.024 · Cited by 186
“55 Recent efforts applying DL to SD and swept-source OCT images were able to detect early glaucoma and distinguish healthy from mild glaucoma with high accuracy.”
BackgroundSelf-citation
Metadata
- Authors
- Tatham, A. J., & Medeiros, F. A.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2017-12
- Volume
- 124
- Issue
- 12
- Pages
- S57-S65
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2770233253
- Cited by
- 229
- References
- 0
- FWCI
- 13.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detecting Structural Progression in Glaucoma with Optical Coherence Tomography. https://app.cochat.ai/papers/10.1016/j.ophtha.2017.07.015
- The paper
- Tatham, A. J., & Medeiros, F. A. (2017). Detecting Structural Progression in Glaucoma with Optical Coherence Tomography. Ophthalmology. https://doi.org/10.1016/j.ophtha.2017.07.015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.