Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 258

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Update on Intraocular Lens Power Calculation Study Protocols

Hoffer, Kenneth J., Savini, Giacomo · 2021 · Ophthalmology

Abstract

It was almost 40 years ago when one of the authors (K.J.H.) published an organized system to quantify the accuracy of intraocular lens (IOL) power calculation formulas, methods, and instruments. At the behest of the editor of the American Journal of Ophthalmology, the IOL Power Club (along with a statistician) published an editorial in 2015 modernizing and quantifying the proper protocols for these studies. Over the past decade, so many new optical biometers, formulas, and methods (whose accuracies have yet to be completely tested) have been introduced that we were asked to modernize and update these guidelines yet again to help others design and report correctly the results of clinical studies on IOL power calculation and biometry for 2020. We evaluated guidelines to enroll patients, including visual acuity minimums, exclusion of bilateral eyes, sample size issues, demographics (age, gender, and ethnicity), and whether such studies should not be performed using the same data that were used to develop the formula being tested. We showed the absolute need for constant optimization, which formulas should be tested for comparison, refraction measurement (testing distance), as well as the analysis of the prediction error (median and mean absolute errors; standard deviation; range of errors; percentage of eyes with a prediction within ±0.25 diopter [D], ±0.50 D, ±0.75 D, and ±1.00 D; and interquartile displays) and statistical methods of analyses. We present methods of ranking formula accuracy, including the new Haigis IOL Formula Performance Index. We also point out the issues of who programmed the formulas being tested, that all formulas used in the study must be referenced, and the software version number of all instruments used in the study should be stated clearly. The definition of anterior chamber depth should be stated as measured from the corneal epithelium to the lens. We hope that these recommendations will help researchers to improve the validity and accuracy of their studies with the ultimate goal to improve the accuracy of IOL power calculation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ophtha.2020.07.005

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Metadata

Authors
Hoffer, K. J., & Savini, G.
Venue
Ophthalmology
Publisher
Elsevier BV
Published
2021-11
Volume
128
Issue
11
Pages
e115-e120
ISSN
0161-6420 (ISSN-L)
OpenAlex
W3048985728
Cited by
258
References
8
FWCI
17.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Update on Intraocular Lens Power Calculation Study Protocols. https://app.cochat.ai/papers/10.1016/j.ophtha.2020.07.005
The paper
Hoffer, K. J., & Savini, G. (2021). Update on Intraocular Lens Power Calculation Study Protocols. Ophthalmology. https://doi.org/10.1016/j.ophtha.2020.07.005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.