Efficacy and Safety of 8 Atropine Concentrations for Myopia Control in Children
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
TOPIC: Comparative efficacy and safety of different concentrations of atropine for myopia control. CLINICAL RELEVANCE: Atropine is known to be an effective intervention to delay myopia progression. Nonetheless, no well-supported evidence exists yet to rank the clinical outcomes of various concentrations of atropine. METHODS: We searched PubMed, EMBASE, Cochrane Central Register of Controlled Trials, the World Health Organization International Clinical Trials Registry Platform, and ClinicalTrials.gov on April 14, 2021. We selected studies involving atropine treatment of at least 1 year's duration for myopia control in children. We performed a network meta-analysis (NMA) of randomized controlled trials (RCTs) and compared 8 atropine concentrations (1% to 0.01%). We ranked the atropine concentrations for the corresponding outcomes by P score (estimate of probability of being best treatment). Our primary outcomes were mean annual changes in refraction (diopters/year) and axial length (AXL; millimeters/year). We extracted data on the proportion of eyes showing myopia progression and safety outcomes (photopic and mesopic pupil diameter, accommodation amplitude, and distance and near best-corrected visual acuity [BCVA]). RESULTS: Thirty pairwise comparisons from 16 RCTs (3272 participants) were obtained. Our NMA ranked the 1%, 0.5%, and 0.05% atropine concentrations as the 3 most beneficial for myopia control, as assessed for both primary outcomes: 1% atropine (mean differences compared with control: refraction, 0.81 [95% confidence interval (CI), 0.58-1.04]; AXL, -0.35 [-0.46 to -0.25]); 0.5% atropine (mean differences compared with control: refraction, 0.70 [95% CI, 0.40-1.00]; AXL, -0.23 [-0.38 to -0.07]); 0.05% atropine (mean differences compared with control: refraction, 0.62 [95% CI, 0.17-1.07]; AXL, -0.25 [-0.44 to -0.06]). In terms of myopia control as assessed by relative risk (RR) for overall myopia progression, 0.05% was ranked as the most beneficial concentration (RR, 0.39 [95% CI, 0.27-0.57]). The risk for adverse effects tended to rise as the atropine concentration was increased, although this tendency was not evident for distance BCVA. No valid network was formed for near BCVA. DISCUSSION: The ranking probability for efficacy was not proportional to dose (i.e., 0.05% atropine was comparable with that of high-dose atropine [1% and 0.5%]), although those for pupil size and accommodation amplitude were dose related.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RoB 2: a revised tool for assessing risk of bias in randomised trials
Sterne, J. A. C., Savović, J., Page, M. J., Elbers, R. G., Blencowe, N. S., Boutron, I., Cates, C. J., Cheng, H.-Y., Corbett, M. S., Eldridge, S. M., et al. (2019) · BMJ · doi:10.1136/bmj.l4898 · Cited by 34,787
Hutton, B., Salanti, G., Caldwell, D. M., Chaimani, A., Schmid, C. H., Cameron, C., Ioannidis, J. P. A., Straus, S., Thorlund, K., Jansen, J. P., et al. (2015) · Annals of Internal Medicine · doi:10.7326/m14-2385 · Cited by 8,269
Salanti, G., Ades, A. E., & Ioannidis, J. P. A. (2011) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2010.03.016 · Cited by 3,766
Checking consistency in mixed treatment comparison meta-analysis
Dias, S., Welton, N. J., Caldwell, D. M., & Ades, A. E. (2010) · Statistics in Medicine · doi:10.1002/sim.3767 · Cited by 2,521
Publication and related bias in meta-analysis
Sterne, J. A. C., Gavaghan, D., & Egger, M. (2000) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(00)00242-0 · Cited by 2,282
Plea for routinely presenting prediction intervals in meta-analysis.
IntHout, J., Ioannidis, J. P. A., Rovers, M. M., & Goeman, J. J. (2016) · BMJ Open · doi:10.1136/bmjopen-2015-010247 · Cited by 2,264
Consistency and inconsistency in network meta-analysis: concepts and models for multi-arm studies
Higgins, J. P. T., Jackson, D., Barrett, J. K., Lu, G., Ades, A. E., & White, I. R. (2012) · Research Synthesis Methods · doi:10.1002/jrsm.1044 · Cited by 2,098
CINeMA: an approach for assessing confidence in the results of a network meta-analysis
Nikolakopoulou, A., Higgins, J. P. T., Papakonstantinou, T., Chaimani, A., Del Giovane, C., Egger, M., & Salanti, G. (2020) · PLOS Medicine · doi:10.1371/journal.pmed.1003082 · Cited by 1,935
Ranking treatments in frequentist network meta-analysis works without resampling methods
Rücker, G., & Schwarzer, G. (2015) · BMC Medical Research Methodology · doi:10.1186/s12874-015-0060-8 · Cited by 1,732
Salanti, G. (2012) · Research Synthesis Methods · doi:10.1002/jrsm.1037 · Cited by 1,729
Metadata
- Authors
- Ha, A., Kim, S. J., Shim, S. R., Kim, Y. K., & Jung, J. H.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2022-03
- Volume
- 129
- Issue
- 3
- Pages
- 322-333
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W3209356343
- Cited by
- 179
- References
- 19
- FWCI
- 14.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficacy and Safety of 8 Atropine Concentrations for Myopia Control in Children. https://app.cochat.ai/papers/10.1016/j.ophtha.2021.10.016
- The paper
- Ha, A., Kim, S. J., Shim, S. R., Kim, Y. K., & Jung, J. H. (2022). Efficacy and Safety of 8 Atropine Concentrations for Myopia Control in Children. Ophthalmology. https://doi.org/10.1016/j.ophtha.2021.10.016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.