Overnight corneal swelling with high and low powered silicone hydrogel lenses
Open accessAbstract
PURPOSE: To compare central corneal swelling after eight hours of sleep in eyes wearing four different silicone hydrogel lenses with three different powers. METHODS: Twenty-nine neophyte subjects wore lotrafilcon A (Dk, 140), balafilcon A (Dk, 91), galyfilcon A (Dk, 60) and senofilcon A (Dk, 103) lenses in powers -3.00, -10.00 and +6.00 D on separate nights, in random order, and on one eye only. The contra-lateral eye (no lens) served as the control. Central corneal thickness was measured using a digital optical pachometer before lens insertion and immediately after lens removal on waking. RESULTS: For the +6.00 D and -10.00 D, lotrafilcon A induced the least swelling and galyfilcon A the most. The +6.00 D power, averaged across lens materials, induced significantly greater central swelling than the -10.00 and -3.00 D (Re-ANOVA, p<0.001), (7.7±2.9% vs. 6.8±2.8% and 6.5±2.5% respectively) but there was no difference between -10.00 and -3.00 D. Averaged for power, lotrafilcon A induced the least (6.2±2.8%) and galyfilcon A the most (7.6±3.0%) swelling at the center (Re-ANOVA, p<0.001). Central corneal swelling with +6.00 D was significantly greater than -10.00 D lens power despite similar levels of average lens transmissibility of these two lens powers. CONCLUSIONS: The differences in corneal swelling of the lens wearing eyes are consistent with the differences in oxygen transmission of the silicone hydrogel lenses. In silicone hydrogel lenses central corneal swelling is mainly driven by central lens oxygen transmissibility.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For example, based on the concentration of the glucose, the intensity of an LED embedded in the contact lens can change, where the light output can be quantified using a smartphone camera.”
From Wearables in Medicine (2018) · cites this paper as [64]
In the citing paper
“Similarly, for semiquantitative applications, for example, when the glucose concentration in tears decreases below 0.9 mmol L−1 (threshold value), and the LED in the contact lens can be turned on or off.64”
From Wearables in Medicine (2018) · cites this paper as [64]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 29
- Holden, 1984, Critical oxygen levels to avoid corneal edema for daily and extended wear contact-lenses, Invest Ophthalmol Vis Sci, 25, 1161
- Harvitt, 1999, Re-evaluation of the oxygen diffusion model for predicting minimum contact lens Dk/t values needed to avoid corneal anoxia, Optom Vis Sci, 76, 712, 10.1097/00006324-199910000-00023 · DOI
- Comstock, 1999, Overnight clinical performance of a high Dk silicone hydrogel soft contact lens, Contact Lens Anterior Eye, 22, 159
- Fonn, 1999, Sympathetic swelling response of the control eye to soft lenses in the other eye, Invest Ophthalmol Vis Sci, 40, 3116
- Moezzi, 2006, Overnight corneal swelling with silicone hydrogel contact lenses with high oxygen transmissibility, Eye Contact Lens, 32, 277, 10.1097/01.icl.0000224529.14273.26 · DOI
- Steffen, 2007, The impact of silicone hydrogel materials on overnight corneal swelling, Eye Contact Lens, 33, 115, 10.1097/01.icl.0000242166.09513.aa · DOI
- Holden, 1983, Corneal swelling response to contact lenses worn under extended wear conditions, Invest Ophthalmol Vis Sci, 24, 218
- Holden, 1985, Topographical corneal oedema, Acta Ophthalmol (Copenh), 63, 684, 10.1111/j.1755-3768.1985.tb01581.x · DOI
- Bonanno, 1985, Central and peripheral corneal swelling accompanying soft lens extended wear, Am J Optom Physiol Opt, 62, 74, 10.1097/00006324-198502000-00002 · DOI
- Tomlinson, 1985, Determination of the effective diameter for the calculation of equivalent thickness of soft contact lenses, Am J Optom Physiol Opt, 62, 398, 10.1097/00006324-198506000-00007 · DOI
- Fatt, 1979, The definition of thickness for a lens, Am J Optom Physiol Opt, 56, 324, 10.1097/00006324-197905000-00007 · DOI
- Wilson, 1979, Hydrogel lens power and oxygen transmissibility, Am J Optom Physiol Opt, 56, 430, 10.1097/00006324-197907000-00004 · DOI
- Brennan, 1984, Average thickness of a hydrogel lens for gas transmissibility calculations, Am J Optom Physiol Opt, 61, 627, 10.1097/00006324-198410000-00002 · DOI
- Erickson, 1996, Effects of hydrogel lens transmissibility profiles on local corneal swelling during eye closure, Optom Vis Sci, 73, 169, 10.1097/00006324-199603000-00008 · DOI
- Moezzi, 2011, Distribution of overnight corneal swelling across subjects with 4 different silicone hydrogel lenses, Eye Contact Lens, 37, 61, 10.1097/ICL.0b013e31820e0bc3 · DOI
- Haque, 2007, Corneal refractive therapy with different lens materials, part 1: corneal, stromal, and epithelial thickness changes, Optom Vis Sci, 84, 343, 10.1097/OPX.0b013e318042af1d · DOI
- Hamano, 2008, Corneal thickness change induced by dozing while wearing hydrogel and silicone hydrogel lenses, Eye Contact Lens, 34, 56, 10.1097/ICL.0b013e318073cf5d · DOI
- Hill, 1977, Behind the closed lid, Int Cont Lens Clin, 4, 68
- Holden, 1984, The minimum precorneal oxygen tension to avoid corneal edema, Invest Ophthalmol Vis Sci, 25, 476
- Holden, 1987, Hydrogel contact lenses impede carbon dioxide efflux from the human cornea, Curr Eye Res, 6, 1283, 10.3109/02713688708997553 · DOI
- Bonanno, 1987, Corneal acidosis during contact lens wear: effects of hypoxia and CO2, Invest Ophthalmol Vis Sci, 28, 1514
- Bonanno, 1987, Effect of rigid contact lens oxygen transmissibility on stromal pH in the living human eye, Ophthalmology, 94, 1305, 10.1016/S0161-6420(87)80016-7 · DOI
- Martin, 1986, The presence of a contact lens induces a very small increase in the anterior corneal surface temperature, Acta Ophthalmol (Copenh), 64, 512, 10.1111/j.1755-3768.1986.tb06964.x · DOI
- Holden, 1989, The Glenn A. Fry Award lecture 1988: the ocular response to contact lens wear, Optom Vis Sci, 66, 717, 10.1097/00006324-198911000-00001 · DOI
- Brennan, 1987, Critical oxygen requirements to avoid oedema of the central and peripheral cornea, Acta Ophthalmol (Copenh), 65, 556, 10.1111/j.1755-3768.1987.tb07040.x · DOI
- Efron, 1996, Distribution of oxygen across the surface of the human cornea during soft contact lens wear, Optom Vis Sci, 73, 659, 10.1097/00006324-199610000-00005 · DOI
- Papas, 1998, On the relationship between soft contact lens oxygen transmissibility and induced limbal hyperaemia, Exp Eye Res, 67, 125, 10.1006/exer.1998.0504 · DOI
- Bruce, 2003, Local oxygen transmissibility of disposable contact lenses, Cont Lens Anterior Eye, 26, 189, 10.1016/j.clae.2003.09.001 · DOI
- Holden, 2006, The future of contact lenses: Dk really matters, CL Spectrum, 20
Cited by
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569
Metadata
- Authors
- Moezzi, A. M., Fonn, D., Varikooty, J., & Simpson, T. L.
- Affiliations
- University of Waterloo (CA)
- Corresponding author
- Moezzi, Amir M.
- Venue
- Journal of Optometry
- Publisher
- Elsevier BV
- Published
- 2015-01
- Volume
- 8
- Issue
- 1
- Pages
- 19-26
- ISSN
- 1888-4296 (ISSN-L)
- PMC
- PMC4314620
- OpenAlex
- W2106570134
- Cited by
- 14
- References
- 0
- Citations by year
- 2023: 1 · 2021: 2 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 3 · 2015: 1
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Journal of Optometry (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Ophthalmology › Ocular Surface and Contact Lens
- Health Sciences › Medicine › Ophthalmology › Corneal surgery and disorders
- Health Sciences › Medicine › Ophthalmology › Ocular Infections and Treatments
- Keywords
- silicone hydrogel contact lenses, corneal edema, overnight lens wear, lens power, lotrafilcon A, balafilcon A, senofilcon A, central corneal thickness, corneal oxygenation
- MeSH terms
- Adolescent, Adult, Analysis of Variance, Contact Lenses, Extended-Wear, Contact Lenses, Hydrophilic, Female, Humans, Male, Middle Aged, Silicone Elastomers, Corneal Edema, Hydrogels, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Overnight corneal swelling with high and low powered silicone hydrogel lenses. https://app.cochat.ai/papers/10.1016/j.optom.2014.03.002
- The paper
- Moezzi, A. M., Fonn, D., Varikooty, J., & Simpson, T. L. (2015). Overnight corneal swelling with high and low powered silicone hydrogel lenses. Journal of Optometry. https://doi.org/10.1016/j.optom.2014.03.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.