Cited by 60Obstructive Sleep Apnea ResearchSleep and related disordersNon-Invasive Vital Sign Monitoring

Evaluation of Type 3 Portable Monitoring in Unattended Home Setting for Suspected Sleep Apnea: Factors That May Affect its Accuracy

Yin, Min, Miyazaki, Soichiro, Ishikawa, Kazuo·2006·Otolaryngology–Head and Neck Surgery

Abstract

OBJECTIVE: This study evaluates the reliability of type 3 portable monitoring (PM) in a home setting. STUDY DESIGN AND SETTING: Prospective study in sleep laboratory. Type 3 device (Stardust II) was evaluated in comparison with standard polysomnography (PSG) among patients with obstructive sleep apnea. Quality of recorded data and agreement between PM and PSG results were evaluated. RESULTS: Low quality of recorded data was observed only in 5 cases. Pattern of disordered breathing was recognized correctly by PM. Apnea/hypopnea index (AHI) correlated well with a mean bias of 3.7 ± 13.1/h. High sensitivity of PM was observed generally, whereas specificity was lower in mild patients. AHI, record time, and sleep position were found to be the main factors that would affect the accuracy of PM. CONCLUSION: Type 3 PM is feasible in unattended home‐setting for routine examination. Influence of the factors above should be comprehensively considered especially for mild patients.

Integrity signals

Registry

Crossref · 10.1016/j.otohns.2005.10.019

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Yin, M., Miyazaki, S., & Ishikawa, K.
Affiliations
  • Akita University (JP)
  • Shiga University of Medical Science (JP)
Corresponding author
Ishikawa, Kazuo
Venue
Otolaryngology–Head and Neck Surgery
Publisher
Wiley
Published
2006-02
Volume
134
Issue
2
Pages
204-209
ISSN
  • 0161-6439 (ISSN-L)
  • 0194-5998
  • 1097-6817
OpenAlex
W2004326825
Cited by
60
References
0
Citations by year
2026: 1 · 2024: 2 · 2023: 4 · 2022: 2 · 2021: 2 · 2020: 3 · 2018: 1 · 2017: 4 · 2016: 1 · 2015: 2 · 2014: 7 · 2013: 6 · 2012: 3
FWCI
2.53
Type
journal article
Language
en
Open access
closed
Locations
  • Otolaryngology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
home sleep apnea testing, obstructive sleep apnea, polysomnography comparison, apnea-hypopnea index, diagnostic accuracy, sleep position, recording time, mild sleep apnea
MeSH terms
Adult, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Sleep Apnea, Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review