Inverse Kinematic Alignment for Total Knee Arthroplasty
Open accessAbstract
Patient specific alignment might improve clinical outcomes in total knee arthroplasty (TKA). Different alignment concepts are described, each providing specific features with theoretical benefits or possible disadvantages. Inverse kinematic alignment (iKA) is a new patient specific alignment concept with excellent reported clinical outcome and patient satisfaction at short-term follow-up. iKA is a tibia-first, gap balancing technique restoring the native tibial joint line obliquity (JLO). In each patient, within boundaries, equal medial and lateral tibial resections are performed, compensating for cartilage and bone loss. We describe the surgical technique of iKA using a robotic assisted system (Mako, Stryker, Kalamazoo, USA). A case series of 100 consecutive iKA cases is assessed and the bony resections and resection angles are reported. Both in the coronal plane and axial plane, iKA might offer advantages over existing alignment strategies, possibly providing optimal clinical outcome and durable long-term survival, regardless of the alignment is varus, neutral or valgus.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Kinematic alignment and related approaches aim to recreate native knee morphology by removing the amount of bone and cartilage that will be exactly replaced by the implant, with the intent of restoring natural kinematics and joint laxities.
“Kinematic alignment and related approaches aim to recreate native knee morphology by removing the amount of bone and cartilage that will be exactly replaced by the implant, with the intent of restoring natural kinematics and joint laxities [6, 7].”
From Imageless robotic total knee arthroplasty determines similar coronal plane alignment of the knee (CPAK) parameters to long leg radiographs (2024) · cites this paper as [7]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 33
- Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KD. Patient satis- faction after total knee arthroplasty: who is satisfied and who is not? Clin Orthop Relat Res 2010;468:57-63.
- Eckhoff DG, Bach JM, Spitzer VM, et al. Three-dimensional mechanics, kinema- tics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg Am 2005;87:71-80.
- Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG. The axes of rotation of the knee. Clin Orthop Relat Res 1993;290:259-68.
- Thienpont E, Schwab PE, Cornu O, Bellemans J, Victor J. Bone morphotypes of the varus and valgus knee. Arch Orthop Trauma Surg 2017;137:393-400.
- Hirschmann MT, Moser LB, Amsler F, Behrend H, Leclerq V, Hess S. Functional knee phenotypes: a novel classification for phenotyping the coronal lower limb alignment based on the native alignment in young non-osteoarthritic patients. Knee Surg Sports Traumatol Arthrosc 2019;27:1394-402.
- Almaawi AM, Hutt JRB, Masse V, Lavigne M, Vendittoli PA. The impact of mechanical and restricted kinematic alignment on knee ana- tomy in total knee arthroplasty. J Arthroplasty 2017;32:2133-40, http://dx.doi.org/10.1016/j.arth.2017.02.028 [Epub 2017 Feb 20. PMID: 28302462]. · DOI
- Pailhé R. Total knee arthroplasty: Latest robotics implantation tech- niques. Orthop Traumatol Surg Res 2021;107:102780, http://dx.doi.org/10. 1016/j.otsr.2020.102780. · DOI
- Bardou-Jacquet J, Murgier J, Laudet F, Fabre T. Combining load sensor and robo- tic technologies for ligament balance in total knee arthroplasty. Orthop Trau- matol Surg Res 2021;10:102889, http://dx.doi.org/10.1016/j.otsr.2021.102889. · DOI
- Insall JN, Binazzi R, Soudry M, Mestriner LA. Total knee arthroplasty. Clin Orthop Relat Res 1985;192:13-22.
- Vanlommel L, Vanlommel J, Claes S, Bellemans J. Slight undercorrection fol- lowing total knee arthroplasty results in superior clinical outcomes in varus knees. Knee Surg Sports Traumatol Arthrosc 2013;21(10):2325-30.
- Howell S, Shelton T, Hull M. Implant survival and function ten years after kine- matically aligned total knee arthroplasty. J Arthroplasty 2018;33:3678-84.
- Abdel M, Ollivier M, Parratte S, Trousdale R, Berry D, Pagnano M. Effect of post- operative mechanical axis alignment on survival and functional outcomes of modern total knee arthroplasties with cement: a concise follow-up at 20 years. J Bone Joint Surg Am 2018;100(6):472-8.
- Rivière C, Iranpour F, Auvinet E, Howell S, Vendittoli PA, Cobb J, Parratte S. Align- ment options for total knee arthroplasty: A systematic review. Orthop Trauma- tol Surg Res 2017;103:1047-56, http://dx.doi.org/10.1016/j.otsr.2017.07.010 [Epub 2017 Aug 31. PMID: 28864235]. · DOI
- Howell SM, Hull ML. Kinematic alignment in total knee arthroplasty. Insall and Scott Surgery of the Knee Philadelphia, PA. Elsevier 2012:1255-68.
- Rivière C, Villet L, Jeremic D, Vendittoli PA. What you need to know about kinematic alignment for total knee arthroplasty. Orthop Traumatol Surg Res 2021;107:102773, http://dx.doi.org/10.1016/j.otsr.2020.102773. · DOI
- Dossett HG, Estrada NA, Swartz GJ, LeFevre GW, Kwasman BG. A ran- domised controlled trial of kinematically and mechanically aligned total knee replacements: two-year clinical results. Bone Joint J 2014;96-B:907-13, http://dx.doi.org/10.1302/0301-620X.96B7.32812. · DOI
- Calliess T, Ettinger M. Limits of kinematic alignment and recom- mendations for its safe application. Orthopade 2020;49:617-24, http://dx.doi.org/10.1007/s00132-020-03931-7 [PMID: 32494904]. · DOI
- Gao ZX, Long NJ, Zhang SY, Yu W, Dai YX, Xiao C. Comparison of kinematic ali- gnment and mechanical alignment in total knee arthroplasty: a meta-analysis of randomized controlled clinical trials. Orthop Surg 2020;12:1567-78, http://dx.doi.org/10.1111/os.12826 [Epub 2020 Oct 25. PMID: 33099892; PMCID: PMC7767667]. · DOI
- Woon JTK, Zeng ISL, Calliess T, Windhagen H, Ettinger M, Waterson HB, et al. Outcome of kinematic alignment using patient-specific instrumentation versus mechanical alignment in TKA: a meta-analysis and subgroup ana- lysis of randomised trials. Arch Orthop Trauma Surg 2018;138:1293-303, http://dx.doi.org/10.1007/s00402-018-2988-8 [Epub 2018 Jun 30. PMID: 29961093]. · DOI
- Blakeney WG, Vendittoli PA. Restricted kinematic alignment: the ideal com- promise? 2020 Jul 1. In: Rivière C, Vendittoli PA, editors. Personalized Hip and Knee Joint Replacement [Internet]. Cham (CH): Springer; 2020 [Chapter 17. PMID: 33347126].
- Winnock de Grave P, Luyckx T, Claeys K, Tampere T, Kellens J, Müller J, et al. Higher satisfaction after total knee arthroplasty using restricted inverse kine- matic alignment compared to adjusted mechanical alignment. Knee Surg Sports Traumatol Arthrosc 2020, http://dx.doi.org/10.1007/s00167-020-06165-4 [Epub ahead of print. PMID:32737528]. · DOI · Paper page
- Calliess T, Ettinger M, Savov P, Karkosch P, Windhagen H. Individualized align- ment in total knee arthroplasty using image-based robotic assistance: Video article. Orthopade 2018;47(10):871-9.
- Hirschmann MT, Moser LB, Amsler F, Behrend H, Leclercq V, Hess S. Phenoty- ping the knee in young non-osteo-arthritic knees shows a wide distribution of femoral and tibial coronal alignment. Knee Surg Sports Traumatol Arthrosc 2019;27(5):1385-93.
- Luyckx T, Vandenneucker H, Ing LS, Vereecke E, Ing AV, Victor J. Raising the joint line in TKA is associated with mid-flexion laxity: a study in cadaver knees. Clin Orthop Relat Res 2018;476:601-11.
- Ghijselings I, Van den Wijngaert H, Demurie A, Van Onsem S, Delport H. The Eeklo modified subvastus approach for total knee arthroplasty: detailed surgical tips and tricks. J Orthop Surg Tech 2021;4:246-53, http://dx.doi.org/10.36959/453/556. · DOI
- Nakajima A, Sonobe M, Akatsu Y, Aoki Y, Takahashi H, Suguro T, et al. Associa- tion between limb alignment and patient-reported outcomes after total knee arthroplasty using an implant that reproduces anatomical geometry. J Orthop Surg Res 2018;13:320.
- Matsuda S, Miura H, Nagamine R, Mawatari T, Tokunaga M, Nabeyama R, et al. Anatomical analysis of the femoral condyle in normal and osteoarthritic knees. J Orthop Res 2004;22:104-9.
- Smith CR, Vignos MF, Lenhart RL, Kaiser J, Thelen DG. The influence of com- ponent alignment and ligament properties on tibiofemoral contact forces in total knee replacement. J Biomech Eng 2016;138:021017.
- Srivastava A, Lee GY, Steklov N, Colwell Jr CW, Ezzet KA, D'Lima DD. Effect of tibial component varus on wear in total knee arthroplasty. Knee 2012;19(5):560-3.
- Thienpont E, Schwab PE, Cornu O, Bellemans J, Victor J. Bone morphotypes of the varus and valgus knee. Arch Orthop Trauma Surg 2017;137:393-400, http://dx.doi.org/10.1007/s00402-017-2626-x [Epub 2017 Jan 21. PMID: 28110363]. · DOI
- Chao TW, Geraghty L, Dimitriou P, Talbot S. Averaging rotational landmarks during total knee arthroplasty reduces component malro- tation caused by femoral asymmetry. J Orthop Surg Res 2017;12:74, http://dx.doi.org/10.1186/s13018-017-0575-2 [PMID: 28499396; PMCID: PMC5429545]. · DOI
- Ng CK, Chen JY, Yeh JZY, Ho JPY, Merican AM, Yeo SJ. Distal femoral rotation correlates with proximal tibial joint line obliquity: a considera- tion for kinematic total knee arthroplasty. J Arthroplasty 2018;33:1936-44, http://dx.doi.org/10.1016/j.arth.2017.12.025 [Epub 2017 Dec 28. PMID: 29395720]. · DOI
- Hayasaka S, Newman C, Walter WL, Talbot S. Coronal tibial alignment is lin- ked to femoral rotational asymmetry: Implications for total knee arthroplasty surgery. Knee 2019;26:435-43, http://dx.doi.org/10.1016/j.knee.2019.01.008 [Epub 2019 Feb 10. PMID:30745220]. · DOI
Cited by
Sorted by citations
Edelstein, A. I., Orsi, A. D., Plaskos, C., Coffey, S., & Suleiman, L. I. (2024) · Arthroplasty · doi:10.1186/s42836-024-00231-9 · Cited by 11 · see citing works
“Kinematic alignment and related approaches aim to recreate native knee morphology by removing the amount of bone and cartilage that will be exactly replaced by the implant, with the intent of restoring natural kinematics and joint laxities [6, 7] .”
Background
- Authors
- Winnock de Grave, P., Kellens, J., Luyckx, T., Tampere, T., Lacaze, F., & Claeys, K.
- Affiliations
- Universitair Ziekenhuis Leuven (BE)
- Ghent University Hospital (BE)
- KU Leuven (BE)
- Venue
- Orthopaedics & Traumatology: Surgery & Research
- Publisher
- Elsevier BV
- Published
- 2022-09
- Volume
- 108
- Issue
- 5
- Pages
- 103305
- ISSN
- 1877-0568 (ISSN-L)
- OpenAlex
- W4225310737
- Cited by
- 82
- References
- 0
- Citations by year
- 2026: 14 · 2025: 28 · 2024: 20 · 2023: 18 · 2022: 1
- FWCI
- 16.08
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Orthopaedics & Traumatology Surgery & Research (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Lirias (submittedVersion, cc-by-nc-nd)
- Topics
- Health Sciences › Medicine › Surgery › Total Knee Arthroplasty Outcomes
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
- Keywords
- total knee arthroplasty, robotic surgery, tibial resection, gap balancing, varus and valgus alignment
- MeSH terms
- Biomechanical Phenomena, Humans, Knee Joint, Knee Prosthesis, Tibia, Arthroplasty, Replacement, Knee, Osteoarthritis, Knee
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›