The DOI matches its Crossref record.
Validity and generalizability of the Withdrawal Assessment Tool-1 (WAT-1) for monitoring iatrogenic withdrawal syndrome in pediatric patients
Open accessAbstract
Critically ill pediatric patients frequently receive prolonged analgesia and sedation to provide pain relief and facilitate intensive care therapies. Iatrogenic withdrawal syndrome occurs when these drugs are stopped abruptly or weaned too rapidly. We investigated the validity and generalizability of the Withdrawal Assessment Tool-1 (WAT-1) in children during weaning of analgesics and sedatives. Of 308 children initially supported on mechanical ventilation for acute respiratory failure, 126 (41%) from 21 centers (median age 1.6 years; interquartile range 0.6-7.7 years) were exposed to 5 or more days of opioids. Subjects were assessed for withdrawal symptoms with the WAT-1, an 11-item (12-point) scale, from the first day of weaning from analgesia/sedation until 72 h after the last opioid dose. A total of 836 daily WAT-1 assessments were completed, with a median (interquartile range) WAT-1 score of 2 (0-4) over 6 (3-9) days per subject. There were no significant differences in WAT-1 scores as a function of age. Factor analyses confirmed that motor-related symptoms and behavioral state accounted for the most variance in WAT-1 scores. Supporting construct validity, cumulative opioid exposures were greater [40.2 (19.7-83.4) vs 17.6 (14.6-39.7) mg/kg, P=.004], length of opioid treatment before weaning was longer [7 (6-11) vs 5 (5-8)days, P=.004], and length of weaning from opioids was longer [10 (6-14) vs 6 (3-9)days, P=.008] in subjects with WAT-1 scores of ≥ 3 compared to subjects with WAT-1 scores of <3. The WAT-1 shows good psychometric performance and generalizability when used to assess clinically important withdrawal symptoms in pediatric intensive care and general ward settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smith, H. A. B., Besunder, J. B., Betters, K. A., Johnson, P. N., Srinivasan, V., Stormorken, A., Farrington, E., Golianu, B., Godshall, A. J., Acinelli, L., et al. (2022) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000002873 · Cited by 505
Harris, J., Ramelet, A.-S., van Dijk, M., Pokorna, P., Wielenga, J., Tume, L., Tibboel, D., & Ista, E. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4344-1 · Cited by 425
Delirium is a Common and Early Finding in Patients in the Pediatric Cardiac Intensive Care Unit
Alvarez, R. V., Palmer, C., Czaja, A. S., Peyton, C., Silver, G., Traube, C., Mourani, P. M., & Kaufman, J. (2018) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2017.11.064 · Cited by 147
Metadata
- Authors
- Franck, L. S., Scoppettuolo, L. A., Wypij, D., & Curley, M. A. Q.
- Venue
- Pain
- Published
- 2012-01
- Volume
- 153
- Issue
- 1
- Pages
- 142-148
- ISSN
- 0304-3959 (ISSN-L)
- OpenAlex
- W2025896105
- Cited by
- 162
- References
- 0
- FWCI
- 7.34
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity and generalizability of the Withdrawal Assessment Tool-1 (WAT-1) for monitoring iatrogenic withdrawal syndrome in pediatric patients. https://app.cochat.ai/papers/10.1016/j.pain.2011.10.003
- The paper
- Franck, L. S., Scoppettuolo, L. A., Wypij, D., & Curley, M. A. Q. (2012). Validity and generalizability of the Withdrawal Assessment Tool-1 (WAT-1) for monitoring iatrogenic withdrawal syndrome in pediatric patients. Pain. https://doi.org/10.1016/j.pain.2011.10.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.