CoChat

Motion sensor strategies for automated optimization of deep brain stimulation in Parkinson's disease

Open access
Pulliam, Christopher L., Heldman, Dustin A., Orcutt, Tseganesh H., Mera, Thomas O., Giuffrida, Joseph P., Vitek, Jerrold L. · 2015 · Parkinsonism & Related Disorders
Cited by 61

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background Deep brain stimulation (DBS) is a well-established treatment for Parkinson’s disease (PD). Optimization of DBS settings can be a challenge due to the number of variables that must be considered, including presence of multiple motor signs, side effects, and battery life. Methods Nine PD subjects visited the clinic for programming at approximately 1, 2, and 4 months post-surgery. During each session, various stimulation settings were assessed and subjects performed motor tasks while wearing a motion sensor to quantify tremor and bradykinesia. At the end of each session, a clinician determined final stimulation settings using standard practices. Sensor-based ratings of motor symptom severities collected during programming were then used to develop two automated programming algorithms – one to optimize symptom benefit and another to optimize battery life. Therapeutic benefit was compared between the final clinician-determined DBS settings and those calculated by the automated algorithm. Results Settings determined using the symptom optimization algorithm would have reduced motor symptoms by an additional 13 percentage points when compared to clinician settings, typically at the expense of increased stimulation amplitude. By adding a battery life constraint, the algorithm would have been able to decrease stimulation amplitude by an average of 50% while maintaining the level of therapeutic benefit observed using clinician settings for a subset of programming sessions. Conclusions Objective assessment in DBS programming can identify settings that improve symptoms or obtain similar benefit as clinicians with improvement in battery life. Both options have the potential to improve post-operative patient outcomes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.parkreldis.2015.01.018

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 61

Metadata

Authors
Pulliam, C. L., Heldman, D. A., Orcutt, T. H., Mera, T. O., Giuffrida, J. P., & Vitek, J. L.
Venue
Parkinsonism & Related Disorders
Publisher
Elsevier BV
Published
2015-04
Volume
21
Issue
4
Pages
378-382
ISSN
1353-8020 (ISSN-L)
OpenAlex
W1975092621
Cited by
61
References
4
FWCI
2.23
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Motion sensor strategies for automated optimization of deep brain stimulation in Parkinson's disease. https://app.cochat.ai/papers/10.1016/j.parkreldis.2015.01.018
The paper
Pulliam, C. L., Heldman, D. A., Orcutt, T. H., Mera, T. O., Giuffrida, J. P., & Vitek, J. L. (2015). Motion sensor strategies for automated optimization of deep brain stimulation in Parkinson's disease. Parkinsonism & Related Disorders. https://doi.org/10.1016/j.parkreldis.2015.01.018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.