The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Linear predictive coding distinguishes spectral EEG features of Parkinson's disease
Open accessAbstract
Objective We have developed and validated a novel EEG-based signal processing approach to distinguish PD and control patients: Linear-predictive-coding EEG Algorithm for PD (LEAPD). This method efficiently encodes EEG time series into features that can detect PD in a computationally fast manner amenable to real time applications. Methods We included a total of 41 PD patients and 41 demographically-matched controls from New Mexico and Iowa. Data for all participants from New Mexico (27 PD patients and 27 controls) were used to evaluate in-sample LEAPD performance, with extensive cross-validation. Participants from Iowa (14 PD patients and 14 controls) were used for out-of-sample tests. Our method utilized data from six EEG leads which were as little as 2 minutes long. Results For the in-sample dataset, LEAPD differentiated PD patients from controls with 85.3±0.1% diagnostic accuracy, 93.3±0.5% area under the receiver operating characteristics curve (AUC), 87.9±0.9% sensitivity, and 82.7±1.1% specificity, with multiple cross-validations. After head-to-head comparison with state-of-the-art methods using our dataset, LEAPD showed a 13% increase in accuracy and a 15.5% increase in AUC. When the trained classifier was applied to a distinct out-of-sample dataset, LEAPD showed reliable performance with 85.7% diagnostic accuracy, 85.2% AUC, 85.7% sensitivity, and 85.7% specificity. No statistically significant effect of levodopa-ON and levodopa-OFF sessions were found. Conclusion We describe LEAPD, an efficient algorithm that is suitable for real time application and captures spectral EEG features using few parameters and reliably differentiates PD patients from demographically-matched controls.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principal component analysis: A review and recent developments
Jolliffe, I. T., & Cadima, J. (2016) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2015.0202 · Cited by 10,117
Adaptive deep brain stimulation in advanced Parkinson disease.
Little, S., Pogosyan, A., Neal, S., Zavala, B., Zrinzo, L., Hariz, M., Foltynie, T., Limousin, P., Ashkan, K., FitzGerald, J., et al. (2013) · Annals of Neurology · doi:10.1002/ana.23951 · Cited by 1,374
Accuracy of clinical diagnosis of Parkinson disease: A systematic review and meta-analysis
Rizzo, G., Copetti, M., Arcuti, S., Martino, D., Fontana, A., & Logroscino, G. (2016) · Neurology · doi:10.1212/wnl.0000000000002350 · Cited by 870 · cited 1×
“However, the accuracy of the diagnosis of PD relies on clinical features and has not improved significantly in 25 years [4].”
Background
Cited by
Loh, H. W., Ooi, C. P., Palmer, E., Barua, P. D., Dogan, S., Tuncer, T., Baygin, M., & Acharya, U. R. (2021) · Electronics · doi:10.3390/electronics10141740 · Cited by 144
“[32] 2020 Power spectra density Linear-predictive-coding EEG Algorithm for PD (LEAPD) 27—Healthy 27—PD 93.”
den Eynde, S. V., Diaz-Romero, D. J., Engelen, B., Zaplana, I., & Peeters, J. R. (2022) · Procedia CIRP · doi:10.1016/j.procir.2022.02.046 · Cited by 30
Metadata
- Authors
- Anjum, M. F., Dasgupta, S., Mudumbai, R., Singh, A., Cavanagh, J. F., & Narayanan, N. S.
- Venue
- Parkinsonism & Related Disorders
- Publisher
- Elsevier BV
- Published
- 2020-10
- Volume
- 79
- Pages
- 79-85
- ISSN
- 1353-8020 (ISSN-L)
- OpenAlex
- W3080914981
- Cited by
- 183
- References
- 3
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Linear predictive coding distinguishes spectral EEG features of Parkinson's disease. https://app.cochat.ai/papers/10.1016/j.parkreldis.2020.08.001
- The paper
- Anjum, M. F., Dasgupta, S., Mudumbai, R., Singh, A., Cavanagh, J. F., & Narayanan, N. S. (2020). Linear predictive coding distinguishes spectral EEG features of Parkinson's disease. Parkinsonism & Related Disorders. https://doi.org/10.1016/j.parkreldis.2020.08.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.