Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 318

The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.

Automated invasive ductal carcinoma detection based using deep transfer learning with whole-slide images

Celik, Yusuf, Talo, Muhammed, Yildirim, Ozal, Karabatak, Murat, Acharya, U Rajendra·2020·Pattern Recognition Letters

Abstract

Abstract Advances in artificial intelligence technologies have made it possible to obtain more accurate and reliable results using digital images. Due to the advances in digital histopathological images obtained using whole slide image (WSI) scanners, automated analysis of digital images by computer support systems has become interesting. In particular, deep learning architectures, are one of the preferred approaches in the analysis of digital histopathology images. The deeper networks trained on large amounts of image data are adapted for different tasks using transfer learning technique. In this study, automated detection of invasive ductal carcinoma (IDC), which is the most common subtype of breast cancers, is proposed using deep transfer learning technique. We have used deep learning pre-trained models, ResNet-50 and DenseNet-161 for the IDC detection task. The public histopathology dataset containing 277,524 image patches were used in our experimental studies. As a result of training on the last layers of pre-trained deep networks, DenseNet-161 model has yielded F-sore of 92.38% and balanced accuracy value of 91.57%. Similarly, we have obtained F-score of 94.11% and balanced accuracy value of 90.96% using ResNet-50 architecture. In addition, our developed model is validated using the publicly available BreakHis breast cancer dataset and obtained promising results in classifying magnification independent histopathology images into benign and malignant classes. Our developed system obtained the highest classification performance as compared to the state-of-art techniques and is ready to be tested with more diverse huge databases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.patrec.2020.03.011

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 59 references

Cited by

See all 318

Metadata

Authors
Celik, Y., Talo, M., Yildirim, O., Karabatak, M., & Acharya, U. R.
Venue
Pattern Recognition Letters
Publisher
Elsevier BV
Published
2020-05
Volume
133
Pages
232-239
ISSN
0167-8655 (ISSN-L)
OpenAlex
W3009928129
Cited by
318
References
59
FWCI
22.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated invasive ductal carcinoma detection based using deep transfer learning with whole-slide images. https://app.cochat.ai/papers/10.1016/j.patrec.2020.03.011
The paper
Celik, Y., Talo, M., Yildirim, O., Karabatak, M., & Acharya, U. R. (2020). Automated invasive ductal carcinoma detection based using deep transfer learning with whole-slide images. Pattern Recognition Letters. https://doi.org/10.1016/j.patrec.2020.03.011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.