Dealing with fuel contaminants in biogas-fed solid oxide fuel cell (SOFC) and molten carbonate fuel cell (MCFC) plants: Degradation of catalytic and electro-catalytic active surfaces and related gas purification methods

Open access
Lanzini, Andrea, Madi, Hossein, Chiodo, Vitaliano, Papurello, Davide, Maisano, Susanna, Santarelli, Massimo, Van herle, Jan·2017·Progress in Energy and Combustion Science

Abstract

Abstract Fuel cell and hydrogen technologies are re-gaining momentum in a number of sectors including industrial, tertiary and residential ones. Integrated biogas fuel cell plants in wastewater treatment plants and other bioenergy recovery plants are nowadays on the verge of becoming a clear opportunity for the market entry of high-temperature fuel cells in distributed generation (power production from a few kW to the MW scale). High-temperature fuel cell technologies like molten carbonate fuel cells (MCFCs) and solid oxide fuel cells (SOFCs) are especially fit to operate with carbon fuels due to their (direct or indirect) internal reforming capability. Especially, systems based on SOFC technology show the highest conversion efficiency of gaseous carbon fuels (e.g., natural gas, digester gas, and biomass-derived syngas) into electricity when compared to engines or gas turbines. Also, lower CO 2 emissions and ultra-low emissions of atmospheric contaminants (SO X , CO, VOC, especially NO X ) are generated per unit of electricity output. Nonetheless, stringent requirements apply regarding fuel purity. The presence of contaminants within the anode fuel stream, even at trace levels (sometimes ppb levels) can reduce the lifetime of key components like the fuel cell stack and reformer. In this work, we review the complex matrix (typology and amount) of different contaminants that is found in different biogas types (anaerobic digestion gas and landfill gas). We analyze the impact of contaminants on the fuel reformer and the SOFC stack to identify the threshold limits of the fuel cell system towards specific contaminants. Finally, technological solutions and related adsorbent materials to remove contaminants in a dedicated clean-up unit upstream of the fuel cell plant are also reviewed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.pecs.2017.04.002

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 163

Metadata

Authors
Lanzini, A., Madi, H., Chiodo, V., Papurello, D., Maisano, S., Santarelli, M., & Van herle, J.
Venue
Progress in Energy and Combustion Science
Publisher
Elsevier BV
Published
2017-07
Volume
61
Pages
150-188
ISSN
0360-1285 (ISSN-L)
OpenAlex
W2610874823
Cited by
163
References
1
FWCI
8.92
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dealing with fuel contaminants in biogas-fed solid oxide fuel cell (SOFC) and molten carbonate fuel cell (MCFC) plants: Degradation of catalytic and electro-catalytic active surfaces and related gas purification methods. https://app.cochat.ai/papers/10.1016/j.pecs.2017.04.002
The paper
Lanzini, A., Madi, H., Chiodo, V., Papurello, D., Maisano, S., Santarelli, M., & Van herle, J. (2017). Dealing with fuel contaminants in biogas-fed solid oxide fuel cell (SOFC) and molten carbonate fuel cell (MCFC) plants: Degradation of catalytic and electro-catalytic active surfaces and related gas purification methods. Progress in Energy and Combustion Science. https://doi.org/10.1016/j.pecs.2017.04.002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.