Evaluation of measures for assessing time-saving of automatic organ-at-risk segmentation in radiotherapy
Open accessAbstract
BACKGROUND AND PURPOSE: In radiotherapy, automatic organ-at-risk segmentation algorithms allow faster delineation times, but clinically relevant contour evaluation remains challenging. Commonly used measures to assess automatic contours, such as volumetric Dice Similarity Coefficient (DSC) or Hausdorff distance, have shown to be good measures for geometric similarity, but do not always correlate with clinical applicability of the contours, or time needed to adjust them. This study aimed to evaluate the correlation of new and commonly used evaluation measures with time-saving during contouring. MATERIALS AND METHODS: Twenty lung cancer patients were used to compare user-adjustments after atlas-based and deep-learning contouring with manual contouring. The absolute time needed (s) of adjusting the auto-contour compared to manual contouring was recorded, from this relative time-saving (%) was calculated. New evaluation measures (surface DSC and added path length, APL) and conventional evaluation measures (volumetric DSC and Hausdorff distance) were correlated with time-recordings and time-savings, quantified with the Pearson correlation coefficient, R. RESULTS: The highest correlation (R = 0.87) was found between APL and absolute adaption time. Lower correlations were found for APL with relative time-saving (R = -0.38), for surface DSC with absolute adaption time (R = -0.69) and relative time-saving (R = 0.57). Volumetric DSC and Hausdorff distance also showed lower correlation coefficients for absolute adaptation time (R = -0.32 and 0.64, respectively) and relative time-saving (R = 0.44 and -0.64, respectively). CONCLUSION: Surface DSC and APL are better indicators for contour adaptation time and time-saving when using auto-segmentation and provide more clinically relevant and better quantitative measures for automatically-generated contour quality, compared to commonly-used geometry-based measures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gooding, M. J., Smith, A. J., Tariq, M., Aljabar, P., Peressutti, D., van der Stoep, J., Reymen, B., Emans, D., Hattu, D., van Loon, J., et al. (2018) · Medical Physics · doi:10.1002/mp.13200 · Cited by 89 · cited 2×
“showed that it is difficult for a clinical observer to determine whether a contour was automatically generated or manually delineated if the automated contour is at a certain quality level [9].”
BackgroundSelf-citation
Cited by
Metrics reloaded: recommendations for image analysis validation
Maier-Hein, L., Reinke, A., Godau, P., Tizabi, M. D., Buettner, F., Christodoulou, E., Glocker, B., Isensee, F., Kleesiek, J., Kozubek, M., et al. (2024) · Nature Methods · doi:10.1038/s41592-023-02151-z · Cited by 470
Nikolov, S., Blackwell, S., Zverovitch, A., Mendes, R., Livne, M., De Fauw, J., Patel, Y., Meyer, C., Askham, H., Romera-Paredes, B., et al. (2021) · Journal of Medical Internet Research · doi:10.2196/26151 · Cited by 366
Understanding metric-related pitfalls in image analysis validation
Reinke, A., Tizabi, M. D., Baumgartner, M., Eisenmann, M., Heckmann-Nötzel, D., Kavur, A. E., Rädsch, T., Sudre, C. H., Acion, L., Antonelli, M., et al. (2024) · Nature Methods · doi:10.1038/s41592-023-02150-0 · Cited by 241
Common Limitations of Image Processing Metrics: A Picture Story
Reinke, A., Tizabi, M. D., Sudre, C. H., Eisenmann, M., Rädsch, T., Baumgartner, M., Acion, L., Antonelli, M., Arbel, T., Bakas, S., et al. (2021) · arXiv · doi:10.48550/arxiv.2104.05642 · Cited by 126
Metrics reloaded: Recommendations for image analysis validation
Maier-Hein, L., Reinke, A., Godau, P., Tizabi, M. D., Buettner, F., Christodoulou, E., Glocker, B., Isensee, F., Kleesiek, J., Kozubek, M., et al. (2022) · arXiv · doi:10.48550/arxiv.2206.01653 · Cited by 59
Metadata
- Authors
- Vaassen, F., Hazelaar, C., Vaniqui, A., Gooding, M., van der Heyden, B., Canters, R., & van Elmpt, W.
- Venue
- Physics and Imaging in Radiation Oncology
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 13
- Pages
- 1-6
- ISSN
- 2405-6316 (ISSN-L)
- OpenAlex
- W2994739006
- Cited by
- 204
- References
- 1
- FWCI
- 11.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of measures for assessing time-saving of automatic organ-at-risk segmentation in radiotherapy. https://app.cochat.ai/papers/10.1016/j.phro.2019.12.001
- The paper
- Vaassen, F., Hazelaar, C., Vaniqui, A., Gooding, M., van der Heyden, B., Canters, R., & van Elmpt, W. (2020). Evaluation of measures for assessing time-saving of automatic organ-at-risk segmentation in radiotherapy. Physics and Imaging in Radiation Oncology. https://doi.org/10.1016/j.phro.2019.12.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.