Cited by 14Clinical Laboratory Practices and Quality ControlDiabetes Management and ResearchAdvanced Glycation End Products research

Comparison of a point-of-care analyser for the determination of HbA1c with HPLC method

Open access
Grant, D.A., Dunseath, G.J., Churm, R., Luzio, S.D.·2017·Practical Laboratory Medicine

Abstract

AIMS: As the use of Point of Care Testing (POCT) devices for measurement of glycated haemoglobin (HbA1c) increases, it is imperative to determine how their performance compares to laboratory methods. This study compared the performance of the automated Quo-Test POCT device (EKF Diagnostics), which uses boronate fluorescence quenching technology, with a laboratory based High Performance Liquid Chromatography (HPLC) method (Biorad D10) for measurement of HbA1c. METHODS: Whole blood EDTA samples from subjects (n=100) with and without diabetes were assayed using a BioRad D10 and a Quo-Test analyser. Intra-assay variation was determined by measuring six HbA1c samples in triplicate and inter-assay variation was determined by assaying four samples on 4 days. Stability was determined by assaying three samples stored at -20 °C for 14 and 28 days post collection. RESULTS: =0.969, P<0.0001). Mean (range) intra- and inter-assay variation was 1.2% (0.0-2.7%) and 1.6% (0.0-2.7%) for the D10 and 3.5% (0.0-6.7%) and 2.7% (0.7-5.1%) for the Quo-Test. Mean change in HbA1c after 28 days storage at -20 °C was -0.7% and +0.3% for D10 and Quo-Test respectively. Compared to the D10, Quo-Test showed 98% agreement for diagnosis of glucose intolerance (IGT and T2DM) and 100% for diagnosis of T2DM. CONCLUSION: Good agreement between the D10 and Quo-Test was seen across a wide HbA1c range. The Quo-Test POCT device provided similar performance to a laboratory based HPLC method.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.plabm.2017.04.001

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The systematic review and meta-analysis included 11 studies involving 1,593 participants and 3,285 paired HbA1c measurements comparing POC devices with reference HPLC-based laboratory methods.

    “A total of 11 studies involving 1,593 participants and 3,285 paired measurements were included.”

    From Comparison of point‑of‑care HbA1c devices with laboratory HPLC methods: A systematic review and meta‑analysis (2026) · cites this paper as [12]

    The Abstract (Methods) and Materials and methods (Method comparison; page unavailable) describe a single comparison using 100 blood samples, not a systematic review or meta-analysis of 11 studies. The cited paper therefore does not support the attributed totals of 1,593 participants and 3,285 paired measurements. (LLM, conf=0.90)

    Checked by a reasoning model — may be wrong.

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 8

  1. [1]Alberti K.G. Zimmet P.Z. Definition, diagnosis and classification of diabetes mellitus and its complications. Part 1: diagnosis and classification of diabetes mellitus provisional report of a WHO consultation Diabet. Med. 15 1998 539 553 9686693
  2. [2]Ejilemele A. Unabia J. Ju H. Petersen J.R. A1c Gear: laboratory quality HbA1c measurement at the point of care Clin. Chem. Acta 445 2015 139 142 25801216
  3. [3]Mishra A. Garg S. HbA1c and blood glucose for the diagnosis of diabetes Lancet 378 2011 104 106 21705066
  4. [4]Use of Glycated Haemoglobin (HbA1c) in the Diagnosis of Diabetes Mellitus, Abbreviated report of a WHO Consultation, World Health Organisation, 2011. 26158184
  5. [5]International Expert Committee International expert committee report on the role of A1C assay in the diagnosis of diabetes Diabetes Care 32 2009 1327 19502545 PMC2699715
  6. [6]Sacks D.B. Arnold M. Bakris G.L. Bruns D.E. Horvath A.R. Kirkman M.S. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus Clin. Chem. 57 2011 e1 47 21617152
  7. [7]Saudek C.D. Brick J.C. The clinical use of hemoglobin A1c J. Diab. Sci. Technol. 3 2009 629 634 PMC2769940 20144304
  8. [8]John W.G. Use of HbA1c in the diagnosis of diabetes mellitus in the UK. The implementation of the World Health Organization guidance 2011 Diabet. Med. 29 2012 1350 1357 22957983

Cited by

Sorted by citations

Authors
Grant, D. A., Dunseath, G. J., Churm, R., & Luzio, S. D.
Affiliations
Swansea University (GB)
Corresponding author
Dunseath, G.J.
Venue
Practical Laboratory Medicine
Publisher
Elsevier BV
Published
2017-08
Volume
8
Pages
26-29
ISSN
2352-5517 (ISSN-L)
OpenAlex
W2604375643
Cited by
14
References
0
Citations by year
2026: 2 · 2025: 1 · 2024: 1 · 2023: 2 · 2022: 1 · 2021: 2 · 2020: 2 · 2019: 1 · 2017: 2
FWCI
1.01
Type
journal article
Language
en
Open access
Locations
  • Practical Laboratory Medicine (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Clinical Biochemistry › Advanced Glycation End Products research
Keywords
HbA1c, point-of-care testing, HPLC comparison, assay precision, sample stability, diabetes diagnosis, impaired glucose tolerance, type 2 diabetes

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review