Comparative study on the enzymatic degradation of poly(lactic-co-glycolic acid) by hydrolytic enzymes based on the colorimetric quantification of glycolic acid
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The enzyme-catalysed cleavage of ester bonds of poly(lactic-co-glycolic acid) (PLGA) has been monitored by an improved approach for the quantification of glycolic acid as indicator of copolymer hydrolysis. Glycolic acid released into the degradation medium was determined colorimetrically using chromotropic acid. The assay established is sensitive, as well as being both rapid and economical. The proposed method was applied to assess enzymatic degradation of a series of PLGA polyesters containing different proportions of monomers, end groups of PLGA chains and molecular weights. Among 22 commercially available hydrolytic enzymes (i.e. esterases, lipases and proteases) from different sources, the lipases from Candida antarctica, Candida cylindracea, Candida rugosa, Mucor miehei, Rhizopus arrhizus and porcine pancreas and the esterase from M. miehei all had a significant effect on PLGA degradation, often increasing the rate of ester bond cleavage by a factor of 25 compared to non-enzymatic hydrolysis. The most remarkable substrate specificity was observed for C. antarctica lipase with the rate of degradation being directly proportional to the glycolic acid content. In contrast, degradation by M. miehei esterase and R. arrhizus lipase were nearly independent of PLGA structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jain, R. A. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00115-0 · Cited by 2,214
Properties of lactic acid based polymers and their correlation with composition
Södergård, A., & Stolt, M. (2002) · Progress in Polymer Science · doi:10.1016/s0079-6700(02)00012-6 · Cited by 1,461
Polymer biodegradation: Mechanisms and estimation techniques – A review
Lucas, N., Bienaime, C., Belloy, C., Queneudec, M., Silvestre, F., & Nava-Saucedo, J.-E. (2008) · Chemosphere · doi:10.1016/j.chemosphere.2008.06.064 · Cited by 1,384
Biodegradability and biodegradation of poly(lactide)
Tokiwa, Y., & Calabia, B. P. (2006) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-006-0488-1 · Cited by 665
Alexis, F. (2005) · Polymer International · doi:10.1002/pi.1697 · Cited by 443
Cited by
Metabolizable Semiconducting Polymer Nanoparticles for Second Near‐Infrared Photoacoustic Imaging
Jiang, Y., Upputuri, P. K., Xie, C., Zeng, Z., Sharma, A., Zhen, X., Li, J., Huang, J., Pramanik, M., & Pu, K. (2019) · Advanced Materials · doi:10.1002/adma.201808166 · Cited by 339
Fundamental insights in PLGA degradation from thin film studies
Machatschek, R., & Lendlein, A. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.12.044 · Cited by 73
“In addition to showing good activity against PDLLGAs [14], these enzymes fulfilled the requirement of having negligible surface activity”
BackgroundA comparative analysis of mass losses of some aliphatic polyesters upon enzymatic degradation
Żenkiewicz, M., Richert, A., Malinowski, R., & Moraczewski, K. (2013) · Polymer Testing · doi:10.1016/j.polymertesting.2012.10.011 · Cited by 40
Mayer, J. B., Patil, S. M., Shin, S.-H., Yoo, J., & Won, Y.-Y. (2025) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5c00419 · Cited by 38
Ling, Z., Zheng, Y., Li, Z., Zhao, P., & Chang, H. (2024) · Small · doi:10.1002/smll.202307523 · Cited by 21
Metadata
- Authors
- Kemme, M., Prokesch, I., & Heinzel-Wieland, R.
- Venue
- Polymer Testing
- Publisher
- Elsevier BV
- Published
- 2011-10
- Volume
- 30
- Issue
- 7
- Pages
- 743-748
- ISSN
- 0142-9418 (ISSN-L)
- OpenAlex
- W2045333343
- Cited by
- 55
- References
- 5
- FWCI
- 0.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.