Cited by 207Retinal Development and DisordersIon channel regulation and functionRetinal Diseases and Treatments

Ion channels in the RPE

WIMMERS, S, KARL, M, STRAUSS, O·2007·Progress in Retinal and Eye Research

Abstract

In close interaction with photoreceptors, the retinal pigment epithelium (RPE) plays an essential role for visual function. The analysis of RPE functions, specifically ion channel functions, provides a basis to understand many degenerative diseases of the retina. The invention of the patch-clamp technique significantly improved the knowledge of ion channel structure and function, which enabled a new understanding of cell physiology and patho-physiology of many diseases. In this review, ion channels identified in the RPE will be described in terms of their specific functional role in RPE physiology. The RPE expresses voltage- and ligand-gated K(+), Cl(-), and Ca(2+)-conducting channels. K(+) and Cl(-) channels are involved in transepithelial ion transport and volume regulation. Voltage-dependent Ca(2+) channels act as regulators of secretory activity, and ligand-gated cation channels contribute to RPE function by providing driving forces for ion transport or by influencing intracellular Ca(2+) homoeostasis. Collectively, activity of these ion channels determines the physiology of the RPE and its interaction with photoreceptors. Furthermore, changes in ion channel function, such as mutations in ion channel genes or a changed regulation of ion channel activity, have been shown to lead to degenerative diseases of the retina. Increasing knowledge about the properties of RPE ion channels has not only provided a new understanding of RPE function but has also provided greater understanding of RPE function in health and disease.

Integrity signals

Registry

Crossref · 10.1016/j.preteyeres.2006.12.002

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Polarized expression of ion pumps and channels in the RPE helps regulate the environment around photoreceptors, which is important for photoreceptor electrophysiology and viability.

    “In addition to Na+/K+-ATPase, polarized expression of other ion pumps and channels help regulate the environment around the photoreceptors, which is important for photoreceptor electrophysiology and viability (Wimmers et al., 2007).”

    From The cell biology of the retinal pigment epithelium (2020) · cites this paper as Wimmers et al., 2007

The citation lists haven’t been fetched yet

References 516 · Cited by 207

Authors
WIMMERS, S., KARL, M., & STRAUSS, O.
Affiliations
University Medical Center Hamburg-Eppendorf (DE)
Corresponding author
STRAUSS, O
Venue
Progress in Retinal and Eye Research
Publisher
Elsevier BV
Published
2007-05
Volume
26
Issue
3
Pages
263-301
ISSN
1350-9462 (ISSN-L)
OpenAlex
W2021163002
Cited by
207
References
516
Citations by year
2026: 9 · 2025: 6 · 2024: 22 · 2023: 13 · 2022: 10 · 2021: 9 · 2020: 24 · 2019: 11 · 2018: 9 · 2017: 12 · 2016: 5 · 2015: 9 · 2014: 12 · 2013: 13 · 2012: 13
FWCI
2.38
Type
journal article
Language
en
Open access
closed
Locations
  • Progress in Retinal and Eye Research (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Retinal Development and Disorders
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion channel regulation and function
  • Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
Keywords
retinal pigment epithelium, ion channels, voltage-gated potassium channels, ligand-gated ion channels, voltage-gated calcium channels, chloride channels, transepithelial ion transport, volume regulation, intracellular calcium homeostasis, retinal degeneration, ion channel mutations
MeSH terms
Animals, Humans, Ion Channels, Membrane Potentials, Pigment Epithelium of Eye, Ion Transport, Patch-Clamp Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review