Abstract
The advent of optical coherence tomography (OCT) revolutionized both clinical assessment and research of vitreoretinal conditions. Since then, extraordinary advances have been made in this imaging technology, including the relatively recent development of swept-source OCT (SS-OCT). SS-OCT enables a fast scan rate and utilizes a tunable swept laser at longer wavelengths than conventional spectral-domain devices. These features enable imaging of larger areas with reduced motion artifact, and a better visualization of the choroidal vasculature, respectively. Building on the principles of OCT, swept-source OCT has also been applied to OCT angiography (SS-OCTA), thus enabling a non-invasive in depth-resolved imaging of the retinal and choroidal microvasculature. Despite their advantages, the widespread use of SS-OCT and SS-OCTA remains relatively limited. In this review, we summarize the technical details, advantages and limitations of SS-OCT and SS-OCTA, with a particular emphasis on their relevance for the study of retinal conditions. Additionally, we comprehensively review relevant studies performed to date to the study of retinal health and disease, and highlight current gaps in knowledge and opportunities to take advantage of swept source technology to improve our current understanding of many medical and surgical chorioretinal conditions. We anticipate that SS-OCT and SS-OCTA will continue to evolve rapidly, contributing to a paradigm shift to more widespread adoption of new imaging technology to clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–224 of 224
Fujita, A., Kataoka, K., Takeuchi, J., Nakano, Y., Horiguchi, E., Kaneko, H., Ito, Y., & Terasaki, H. (2020) · Retina · doi:10.1097/iae.0000000000002760 · Cited by 32
Vujosevic, S., Toma, C., Villani, E., Muraca, A., Torti, E., Florimbi, G., Pezzotti, M., Nucci, P., & Cillà, S. D. (2019) · Acta Ophthalmologica · doi:10.1111/aos.14088 · Cited by 31
Horizontal and vertical optic disc rotation. The Beijing Eye Study
Fan, Y., Jonas, J. B., Wang, Y. X., et al. (2017) · PLoS ONE · doi:10.1371/journal.pone.0175749 · Cited by 30
Yasukura, S., Murakami, T., Suzuma, K., Yoshitake, T., Nakanishi, H., Fujimoto, M., Oishi, M., & Tsujikawa, A. (2018) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.18-25108 · Cited by 30
Gendelman, I., Alibhai, A. Y., Moult, E. M., Levine, E. S., Braun, P. X., Mehta, N. B., Zhao, Y., Ishibazawa, A., Sorour, O., Baumal, C. R., et al. (2020) · International Journal of Retina and Vitreous · doi:10.1186/s40942-020-00209-0 · Cited by 28
Rebhun, C. B., Moult, E. M., Ploner, S. B., Neto, C. M., Alibhai, A. Y., Schottenhamml, J., Lee, B., Choi, W., Rifai, F., Tam, M. W., et al. (2017) · Ophthalmology Retina · doi:10.1016/j.oret.2017.08.013 · Cited by 27
McKay, K. M., Vingopoulos, F., Wang, J. C., Papakostas, T. D., Silverman, R. F., Marmalidou, A., Laíns, I., Eliott, D., Vavvas, D. G., Kim, L. A., et al. (2020) · Clinical ophthalmology · doi:10.2147/opth.s214623 · Cited by 27
Self-citationArcari, L., Cimino, S., Luca, L. D., Francone, M., Galea, N., Reali, M., Carbone, I., Iacoboni, C., & Agati, L. (2015) · PLoS ONE · doi:10.1371/journal.pone.0145495 · Cited by 26
Alten, F., Clemens, C. R., Milojcic, C., & Eter, N. (2012) · Retina · doi:10.1097/iae.0b013e3182475b03 · Cited by 23
OCT Angiography and Cone Photoreceptor Imaging in Geographic Atrophy
Qin, J., Rinella, N., Zhang, Q., Zhou, H., Wong, J., Deiner, M. S., Roorda, A., Porco, T. C., Wang, R. K., Schwartz, D. M., et al. (2018) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.18-25032 · Cited by 21
Wang, F., Zhang, Q., Deegan, A. J., Chang, J., & Wang, R. K. (2018) · Eye and Vision · doi:10.1186/s40662-018-0113-2 · Cited by 21
Told, R., Reiter, G. S., Angeli, O., Mittermüller, T. J., Eibenberger, K., Schlanitz, F. G., Arikan, M., Pollreisz, A., Sacu, S., & Schmidt-Erfurth, U. M. (2019) · Retina · doi:10.1097/iae.0000000000002695 · Cited by 20
Zheng, F., Zhang, Q., Motulsky, E. H., Dias, J. R. D. O., Chen, C., Chu, Z., Miller, A. R., Feuer, W. J., Gregori, G., Kubach, S., et al. (2017) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.17-22506 · Cited by 19
Satué, M., Ciprés, M., Melchor, I., Gil‐Arribas, L., Viladés, E., & García‐Martín, E. (2020) · Japanese Journal of Ophthalmology · doi:10.1007/s10384-020-00729-0 · Cited by 19
Prevalence of retinal vein occlusion in the Australian National Eye Health Survey
Keel, S., Xie, J., Foreman, J., van Wijngaarden, P., Taylor, H. R., & Dirani, M. (2017) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.13031 · Cited by 18
Thinner Average Choroidal Thickness Is a Risk Factor for the Onset of Diabetic Retinopathy
Huang, X., Zhang, P., Zou, X., Xu, Y., Zhu, J., He, J., Zhang, B., Lu, L., & Zou, H. (2020) · Ophthalmic Research · doi:10.1159/000504756 · Cited by 17
Díez-Sotelo, M., Díaz, M., Abraldes, M. J., Gómez‐Ulla, F., Penedo, M. G., & Ortega, M. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8101515 · Cited by 14
Liu, L., Yue, S., Wu, J., Zhang, J., Lian, J., Huang, D., Teng, W., & Chen, L. (2015) · Journal of Ophthalmology · doi:10.1155/2015/742686 · Cited by 13
An Improved Microsurgical Ceiling-Mounted Unit and Automated Television
Machemer, R., & Ing, J.-M. P. (1978) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)75949-5 · Cited by 10
Biyik, K. Z., Tideman, J. W. L., Polling, J. R., Buitendijk, G. H. S., Jaddoe, V. V. W., Larsen, M., & Klaver, C. C. W. (2019) · Acta Ophthalmologica · doi:10.1111/aos.14178 · Cited by 10
Roh, M., Miller, J. W., Jeng-Miller, K. W., Wang, J. C., Laíns, I., Silverman, R. F., Loewenstein, J. I., Husain, D., Vavvas, D. G., & Miller, J. B. (2020) · Journal of VitreoRetinal Diseases · doi:10.1177/2474126420916607 · Cited by 10
Self-citationStattin, M., Forster, J., Ahmed, D., Graf, A. C., Krepler, K., & Ansari‐Shahrezaei, S. (2019) · Journal of Ophthalmology · doi:10.1155/2019/4806061 · Cited by 9
Huang, J., Wang, Q., Li, K., Zhang, Q., Xu, G., Liu, J., Zhang, J., Niu, T., Zhang, Q., & Luo, W. (2020) · Neurological Sciences · doi:10.1007/s10072-020-04266-z · Cited by 6
Satué, M., Jarauta, L., Obís, J., Ciprés, M., Rodrigo, M. J., Almárcegui, C., Dolz, I., Ara, J. R., Martin, J., Pablo, L. E., et al. (2019) · Journal of Ophthalmology · doi:10.1155/2019/2890193 · Cited by 5
Cited by
Therapy with voretigene neparvovec. How to measure success?
Stingl, K., Kempf, M., Jung, R., Kortüm, F., Righetti, G., Reith, M., Dimopoulos, S., Ott, S., Kohl, S., & Stingl, K. (2023) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2022.101115 · Cited by 48
Metadata
- Authors
- Laíns, I., Wang, J. C., Cui, Y., Katz, R., Vingopoulos, F., Staurenghi, G., Vavvas, D. G., Miller, J. W., & Miller, J. B.
- Venue
- Progress in Retinal and Eye Research
- Publisher
- Elsevier BV
- Published
- 2021-09
- Volume
- 84
- Pages
- 100951
- ISSN
- 1350-9462 (ISSN-L)
- OpenAlex
- W3127804112
- Cited by
- 324
- References
- 224
- FWCI
- 14.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.