Marginal and internal fit of CAD-CAM inlay/onlay restorations: A systematic review of in vitro studies
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
STATEMENT OF PROBLEM: Different parameters can influence the adaptation of computer-assisted design and computer-assisted manufacturing (CAD-CAM) inlay/onlay restorations. However, systematic reviews to identify and discuss these parameters are lacking. PURPOSE: The purpose of this systematic review was to summarize the scientific literature investigating all parameters that can influence both the marginal and internal adaptation of CAD-CAM inlay/onlay restorations. MATERIAL AND METHODS: An electronic search was conducted by 2 independent reviewers for studies published in English between January 1, 2007 and September 20, 2017 on the PubMed/MEDLINE, Scopus, and Web of Science databases and in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Factors investigated in the selected articles included the type of CAD-CAM system, virtual space parameters, version of the software, type of block, luting procedure, type of restoration, sample size and aging procedure, evaluation method, and number of measurement points per specimen. RESULTS: A total of 162 articles were identified, of which 23 articles met the inclusion criteria. Nine studies investigated adaptation with different restorative materials, 2 evaluated adaptation according to the type of preparation design, 9 compared adaptation before/after thermomechanical loading, and 2 before/after cementation, 1 study investigated marginal adaptation based on whether the optical scan was made intraorally or extraorally, 1 compared adaptation with 5 and 3 axis CAM systems, and 1 assessed adaptation with 4 different intraoral scanners. The risk of bias was high for 7, medium for 15, and low for 1 of the studies reviewed. The high level of heterogeneity across the studies excluded meta-analysis. CONCLUSIONS: Most of the studies reported clinically acceptable values for marginal adaptation. The performance of a CAD-CAM system is influenced by the type of restorative material. A nonretentive cavity preparation exhibited better adaptation than a retentive preparation. Most studies showed that thermomechanical loading affected the quality of marginal adaptation. Cementation increased marginal discrepancies. No statistically significant difference was found for marginal fit of onlays between intraoral and extraoral optical scans using a stone die. The number of milling axes, the type of digital camera, and the region measured were statistically significant in relation to marginal/internal adaptation. Values of adaptation recorded failed to reproduce the preestablished spacer parameters in the software. Clarification is needed concerning adaptation according to the type of preparation design, the type of material, the choice of intrinsic parameters for the CAD process, the type and shape of milling instruments, and the behavior of the material during milling. Adaptation of CAD-CAM inlay/onlays should be evaluated under clinical conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PRISMA-P Group, Moher, D., Shamseer, L., Clarke, M., Ghersi, D., Liberati, A., Petticrew, M., Shekelle, P., & Stewart, L. A. (2015) · Systematic Reviews · doi:10.1186/2046-4053-4-1 · Cited by 26,223 · cited 1×
“This systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement.(29) An electronic search was performed, using 3 electronic databases (PubMed/MEDLINE, Scopus, and Web of Science) for studies published between January 1, 2007 and September 20,…”
MethodThe future of dental devices is digital
van Noort, R. (2012) · Dental Materials · doi:10.1016/j.dental.2011.10.014 · Cited by 1,408
The estimation of cement film thickness by an in vivo technique
McLean, J. W., & von, F. (1971) · British Dental Journal · doi:10.1038/sj.bdj.4802708 · Cited by 1,383
Five-year clinical results of zirconia frameworks for posterior fixed partial dentures.
Sailer, I., Fehér, A., Filser, F., Gauckler, L. J., Lüthy, H., & Hämmerle, C. H. F. (2007) · PubMed · Cited by 807
Considerations in measurement of marginal fit
Holmes, J. R., Bayne, S. C., Holland, G. A., & Sulik, W. D. (1989) · The Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(89)90170-4 · Cited by 769
Advancements in CAD/CAM technology: Options for practical implementation
Alghazzawi, T. F. (2016) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2016.01.003 · Cited by 637 · cited 2×
“The rotary instrument size and shape of the milling unit can influence the adaptation of a restoration.(2,4,25,61,67,70,77) Overmilling of any surface details less than the diameter of the milling rotary instrument will result in a less accurate restoration,(2,70) especially at the line angles of the preparation.”
BackgroundBond strength of universal adhesives: A systematic review and meta-analysis
Rosa, W. L. D. O. D., Piva, E., & Silva, A. F. D. (2015) · Journal of Dentistry · doi:10.1016/j.jdent.2015.04.003 · Cited by 584 · cited 1×
“) independently evaluated the risk of bias of each included study using an adaptation of the methods applied in 2 previous systematic reviews of in vitro studies.(30,31) Descriptions of the following parameters were used to assess each article’s risk of bias (Supplemental Table 1, available online): randomization of t…”
MethodMechanical properties of resin-ceramic CAD/CAM restorative materials
Awada, A., & Nathanson, D. (2015) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2015.04.016 · Cited by 581
Emerging Ceramic-based Materials for Dentistry
Denry, I., & Kelly, J. R. (2014) · Journal of Dental Research · doi:10.1177/0022034514553627 · Cited by 464
Wear, strength, modulus and hardness of CAD/CAM restorative materials
Lawson, N. C., Bansal, R., & Burgess, J. O. (2016) · Dental Materials · doi:10.1016/j.dental.2016.08.222 · Cited by 364
Sarkis-Onofre, R., Skupien, J., Cenci, M., Moraes, R., & Pereira-Cenci, T. (2014) · Operative Dentistry · doi:10.2341/13-070-lit · Cited by 362 · cited 1×
“) independently evaluated the risk of bias of each included study using an adaptation of the methods applied in 2 previous systematic reviews of in vitro studies.(30,31) Descriptions of the following parameters were used to assess each article’s risk of bias (Supplemental Table 1, available online): randomization of t…”
MethodFrom Artisanal to CAD-CAM Blocks: State of the Art of Indirect Composites
Mainjot, A. K., Dupont, N. M., Oudkerk, J. C., Dewael, T. Y., & Sadoun, M. J. (2016) · Journal of Dental Research · doi:10.1177/0022034516634286 · Cited by 343 · cited 1×
“Therefore, this process yields higher mechanical and biological properties than conventionally polymerized composite resins.(12,13) Moreover, these new composite resin blocks have improved resistance to fracture and machinability due to a low elastic modulus close to dentin.”
BackgroundGroten, M., Axmann, D., Pröbster, L., & Weber, H. (2000) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(00)70087-4 · Cited by 308
Mously, H. A., Finkelman, M., Zandparsa, R., & Hirayama, H. (2014) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2014.03.017 · Cited by 230
Boeddinghaus, M., Breloer, E. S., Rehmann, P., & Wöstmann, B. (2015) · Clinical Oral Investigations · doi:10.1007/s00784-015-1430-7 · Cited by 225
Adaptation of all-ceramic fixed partial dentures
Borba, M., Cesar, P. F., Griggs, J. A., & Bona, Á. D. (2011) · Dental Materials · doi:10.1016/j.dental.2011.08.004 · Cited by 193 · cited 4×
“The complex geometry of an inlay/onlay restoration can also influence the accuracy of the intraoral scan.(25,61,70) Furthermore, the technology used by the scanner itself can influence the accuracy of the restoration,(4,20,78-81) whereas few studies have shown any difference.”
BackgroundMethodInfluentialNeves, F. D., Prado, C. J., Prudente, M. S., Carneiro, T. A. P. N., Zancopé, K., Davi, L. R., Mendonça, G., Cooper, L. F., & Soares, C. J. (2014) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2014.04.028 · Cited by 187
Anadioti, E., Aquilino, S. A., Gratton, D. G., Holloway, J. A., Denry, I., Thomas, G. W., & Qian, F. (2014) · Journal of Prosthodontics · doi:10.1111/jopr.12180 · Cited by 183
Ilgenstein, I., Zitzmann, N. U., Bühler, J. M., Wegehaupt, F. J., Attin, T., Weiger, R., & Krastl, G. (2014) · Clinical Oral Investigations · doi:10.1007/s00784-014-1325-z · Cited by 173 · cited 1×
“A significant reduction of continuous margin appeared after thermomechanical loading (TML) in 6 studies,(7,40,41,43-45) whereas 2 did not show a statistically significant difference for marginal adaptation before/after TML(17,19) and 1 found that TML can significantly improve marginal adaptation.(42) One study(20) com…”
BackgroundComparative in vitro evaluation of CAD/CAM vs conventional provisional crowns
ABDULLAH, A. O., TSITROU, E. A., & POLLINGTON, S. (2016) · Journal of Applied Oral Science · doi:10.1590/1678-775720150451 · Cited by 169 · cited 1×
“The range of restorative CAD-CAM material can influence the marginal and internal adaptation of a restoration.(61,63,71,72) This review showed that the performance of a CAD-CAM system relative to marginal/internal fit inlay/onlay restorations is influenced by the type of restorative material.”
BackgroundAhrberg, D., Lauer, H. C., Ahrberg, M., & Weigl, P. (2016) · Clinical Oral Investigations · doi:10.1007/s00784-015-1504-6 · Cited by 163 · cited 2×
“While Da Costa et al(21) did not find a statistically significance difference for the marginal fit of onlays, 4 studies on crowns reported that direct digitalization demonstrated a better adaptation than indirect digitalization.(18,81,86,87) This review had limitations.”
BackgroundEvaluation of marginal and internal fit of ceramic crown copings
Colpani, J. T., Borba, M., & Bona, Á. D. (2012) · Dental Materials · doi:10.1016/j.dental.2012.10.012 · Cited by 162 · cited 1×
“For internal adaptation, values between 70 mm and 120 mm have been proposed.(27,53) Studies reported that an internal gap of 50 mm to 100 mm could result in the most favorable resin cement performance.”
BackgroundAbdel-Azim, T., Rogers, K., Elathamna, E., Zandinejad, A., Metz, M., & Morton, D. (2015) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2015.04.001 · Cited by 159 · cited 2×
“Furthermore, the technology used by the scanner itself can influence the accuracy of the restoration,(4,20,78-81) whereas few studies have shown any difference.(5,68) Another influencing parameter is the luting space setting in the software.”
MethodResultEffect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns
Kale, E., Şeker, E., Yılmaz, B., & Özçelik, T. B. (2016) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2016.05.006 · Cited by 155 · cited 1×
“It was shown that cement space settings had a statistically significant effect on the marginal fit of CAD-CAM restorations(22,26,68) As the marginal fit improved, the cement space decreased.(22) In addition, studies on crowns have also demonstrated that marginal and internal accuracy failed to reproduce the preestabli…”
BackgroundGierthmuehlen, P. C., Vagkopoulou, T., Zhang, Y., Wolkewitz, M., & Strub, J. R. (2013) · Journal of Dentistry · doi:10.1016/j.jdent.2013.10.002 · Cited by 141 · cited 2×
“This parameter is fundamental in explaining variations of adaptation in some areas and between a nonretentive and a retentive inlay/onlay preparation.(6,19,25,70) The type of milling device could affect the results of adaptation,(2,23,37,70,71,76) especially if the restoration has a complex shape, deep groove regions,…”
BackgroundMethodDamage tolerance of indirect restorative materials (including PICN) after simulated bur adjustments
Coldea, A., Fischer, J., Swain, M. V., & Thiel, N. (2015) · Dental Materials · doi:10.1016/j.dental.2015.03.007 · Cited by 126 · cited 1×
“Low hardness and modulus of elasticity have been shown to result in a greater amount of material being removed during grinding.(73) Conversely, other studies have reported that less brittle materials have lower edge chipping, better machinability,(74) and better adaptation.”
BackgroundDemir, N., Öztürk, A. N., & Malkoç, M. A. (2014) · European Journal of Dentistry · doi:10.4103/1305-7456.143612 · Cited by 121 · cited 1×
“The range of restorative CAD-CAM material can influence the marginal and internal adaptation of a restoration.(61,63,71,72) This review showed that the performance of a CAD-CAM system relative to marginal/internal fit inlay/onlay restorations is influenced by the type of restorative material.”
BackgroundKeshvad, A., Hooshmand, T., Farokh, A., Khalilinejad, F., Alihemmati, M., & van Noort, R. (2011) · Journal of Prosthodontics · doi:10.1111/j.1532-849x.2011.00745.x · Cited by 108 · cited 2×
“Therefore, results may not be representative of the whole fit of the restoration.(35,57-60) 3D analysis as microcomputed tomography(25,54,56,61-65) and the triple-scan protocol(20,59,66-69) can be used to evaluate marginal and internal fit.”
MethodMarginal Fit of Heat-pressed vs CAD/CAM Processed All-ceramic Onlays Using a Milling Unit Prototype
Reich, S., Gozdowski, S., Trentzsch, L., Frankenberger, R., & Lohbauer, U. (2008) · Operative Dentistry · doi:10.2341/07-162 · Cited by 95 · cited 1×
“Some studies gave only a mean marginal/internal gap value,(19,28,35) while others gave the mean corresponding values of each region,(17,21,24,33,34,37-39) or at best, values of each reference point selected.(6,25,36,46) Seven studies(6,24,25,33,34,38,46) showed that the region measured was statistically significant in…”
Resultda Costa, J. B., Pelógia, F., Hagedorn, B., & Ferracane, J. L. (2010) · Operative Dentistry · doi:10.2341/09-178-l · Cited by 91 · cited 2×
“Only 1 study investigated adaptation whether the optical scan was made intraorally or extraorally from a gypsum die and found no statistically significant difference between the 2 techniques.(21) One study demonstrated that a 5-axis milling machine provided a better occlusal marginal gap andbetter axial internal gap t…”
BackgroundRogers, K. (2013) · ThinkIR: The University of Louisville's Institutional Repository (University of Louisville) · doi:10.18297/etd/1227 · Cited by 91
D’Arcangelo, C., Żarow, M., Angelis, F. D., Vadini, M., Paolantonio, M., Giannoni, M., & D’Amario, M. (2013) · Clinical Oral Investigations · doi:10.1007/s00784-013-1001-8 · Cited by 87
Bae, S., Park, J. Y., Jeong, I.-D., Kim, H., Kim, J., & Kim, W. (2016) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2016.07.005 · Cited by 82 · cited 2×
“Hence, they can be considered to have high validity and reliability.(20,67,68) A recent study showed that a triple-scan protocol produced a smaller marginal fit than the replica method with less data dispersion.”
BackgroundLong-term Survival of Cerec Restorations: A 10-year Study
Zimmer, S., Göhlich, O., Rüttermann, S., Lang, H., Raab, W. H.-M., & Barthel, C. R. (2008) · Operative Dentistry · doi:10.2341/07-142 · Cited by 79 · cited 2×
“In addition, poor internal fit can increase cement thickness, alter retention, affect occlusion, reduce the fracture resistance of the restorations, and also result in poor marginal fit.(9,27,28) Marginal and internal adaptation is of particular importance for inlay/onlay restorations, as their margins are exposed to…”
BackgroundBoitelle, P., Tapie, L., Mawussi, B. K., & Fromentin, O. (2017) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2017.01.026 · Cited by 77 · cited 3×
“A recent study showed that a triple-scan protocol produced a smaller marginal fit than the replica method with less data dispersion.(68) The range of restorative CAD-CAM material can influence the marginal and internal adaptation of a restoration.”
BackgroundMethodBortolotto, T., Onisor, I., & Krejci, I. (2006) · Clinical Oral Investigations · doi:10.1007/s00784-006-0076-x · Cited by 64
Effect of digital impressions and production protocols on the adaptation of zirconia copings
Kocaağaoğlu, H., Kılınç, H. İ., & Albayrak, H. (2016) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2016.06.004 · Cited by 57
In vitro evaluation of the internal and marginal misfit of CAD/CAM zirconia copings
Lins, L., Pinto, V. B. B., Queiroz, C. S., & Canabarro, A. (2014) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2014.09.010 · Cited by 49
Roggendorf, M. J., Kunzi, B., Ebert, J., Roggendorf, H. C., Frankenberger, R., & Reich, S. (2011) · Clinical Oral Investigations · doi:10.1007/s00784-011-0642-8 · Cited by 45
Kim, J., Cho, B., Lee, J.-H., Kwon, S.-J., Yi, Y., Shin, Y., Roh, B., & Seo, D. (2014) · Acta Odontologica Scandinavica · doi:10.3109/00016357.2014.956145 · Cited by 45 · cited 8×
“These studies used an ANOVA test followed by a Tukey test except 1 study which used a Dunnett T3 test.(25) For marginal fit, only 1 study(38) gave values for the gingival, axial, and occlusal area in a direct measurement and showed that the larger gaps were obtained at the gingival margin.”
BackgroundMethodResultInfluentialFederlin, M., Hiller, K., & Schmalz, G. (2014) · Clinical Oral Investigations · doi:10.1007/s00784-013-1173-2 · Cited by 44
Rippe, M. P., Monaco, C., Volpe, L., Bottıno, M. A., Scotti, R., & Valandro, L. F. (2017) · Operative Dentistry · doi:10.2341/16-093-l · Cited by 38
Marginal adaptation of ceramic and composite inlays in minimally invasive mod cavities
Zaruba, M., Kasper, R. S., Kazama, R., Wegehaupt, F. J., Ender, A., Attin, T., & Mehl, A. C. (2013) · Clinical Oral Investigations · doi:10.1007/s00784-013-0988-1 · Cited by 29
Metadata
- Authors
- Goujat, A., Abouelleil, H., Colon, P., Jeannin, C., Pradelle, N., Seux, D., & Grosgogeat, B.
- Venue
- The Journal of Prosthetic Dentistry
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 121
- Issue
- 4
- Pages
- 590-597.e3
- ISSN
- 0022-3913 (ISSN-L)
- OpenAlex
- W2902350504
- Cited by
- 208
- References
- 43
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.