Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 265

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

CAD-CAM milled versus rapidly prototyped (3D-printed) complete dentures: An in vitro evaluation of trueness

Open access
Kalberer, Nicole, Mehl, Albert, Schimmel, Martin, Müller, Frauke, Srinivasan, Murali·2019·The Journal of Prosthetic Dentistry

Abstract

Statement of problem Complete dentures fabricated by computer‐aided design and computer‐aided manufacturing (CAD‐CAM) techniques have become popular. The 2 principal CAD‐CAM techniques, milling and rapid prototyping (3D printing), used in the fabrication of complete dentures have been reported to yield clinically acceptable results. However, clinical trials or in vitro studies that evaluated the accuracy of the 2 manufacturing techniques are lacking. Purpose The purpose of this in vitro study was to compare the differences in trueness between the CAD‐CAM milled and 3D‐printed complete dentures. Material and methods Two groups of identical maxillary complete dentures were fabricated. A 3D‐printed denture group (3DPD) (n=10) and a milled denture group (MDG) (n=10) from a reference maxillary edentulous model. The intaglio surfaces of the fabricated complete dentures were scanned at baseline using a laboratory scanner. The complete dentures were then immersed in an artificial saliva solution for a period of 21 days, followed by a second scan (after immersion in saliva). A third scan (after the wet‐dry cycle) was then made after 21 days, during which the complete dentures were maintained in the artificial saliva solution during the day and stored dry at night. A purpose‐built 3D comparison software program was used to analyze the differences in the trueness of the complete dentures. The analyses were performed for the entire intaglio surface and specific regions of interest: posterior crest, palatal vault, posterior palatal seal area, tuberosity, anterior ridge, vestibular flange, and mid‐palatal raphae. Independent t tests, ANOVA, and post hoc tests were used for statistical analyses (&agr;=.05). Results The trueness of the milled prostheses was significantly better than that of the rapid prototyping group with regard to the entire intaglio surface (P<.001), posterior crest (P<.001), palatal vault (P<.001), posterior palatal seal area (P<.001), tuberosity (P<.001), anterior ridge (baseline: P<.001; after immersion in saliva: P=.001; after the wet‐dry cycle: P=.011), vestibular flange (P<.001), and mid‐palatal raphae (P<.001). Conclusions The CAD‐CAM, milled complete dentures, under the present manufacturing standards, were superior to the rapidly prototyped complete dentures in terms of trueness of the intaglio surfaces. However, further research is needed on the biomechanical, clinical, and patient‐centered outcome measures to determine the true superiority of one technique over the other with regard to fabricating complete dentures by CAD‐CAM techniques.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.prosdent.2018.09.001

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 265

Metadata

Authors
Kalberer, N., Mehl, A., Schimmel, M., Müller, F., & Srinivasan, M.
Venue
The Journal of Prosthetic Dentistry
Publisher
Elsevier BV
Published
2019-04
Volume
121
Issue
4
Pages
637-643
ISSN
0022-3913 (ISSN-L)
OpenAlex
W2912806347
Cited by
265
References
8
FWCI
33.18
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: CAD-CAM milled versus rapidly prototyped (3D-printed) complete dentures: An in vitro evaluation of trueness. https://app.cochat.ai/papers/10.1016/j.prosdent.2018.09.001
The paper
Kalberer, N., Mehl, A., Schimmel, M., Müller, F., & Srinivasan, M. (2019). CAD-CAM milled versus rapidly prototyped (3D-printed) complete dentures: An in vitro evaluation of trueness. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2018.09.001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.