Influence of operator experience, scanner type, and scan size on 3D scans
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
STATEMENT OF PROBLEM Intraoral scanners (IOSs) have some inherent distortions caused by optical and/or software imperfections. However, how other factors such as operator experience, scan time, scanner type, and scan size influence scan accuracy is not clear. PURPOSE The purpose of this in vitro study was to evaluate the trueness and precision of scans performed by 3 professionals with different levels of experience by using 2 IOSs. MATERIAL AND METHODS Three operators with low, medium, and high levels of experience scanned a master model 10 times by using 2 IOSs (CEREC Omnicam; Dentsply Sirona and TRIOS 3; 3Shape), resulting in 10 standard tessellation language files for each group (N=60). Each standard tessellation language file was divided into 2 areas (prepared teeth and complete arch). Precision was evaluated by comparing the 10 scans from each examiner for each system. Trueness was evaluated by comparing each scan file with a reference scan obtained from a laboratory scanner (D2000; 3Shape). A 3D analysis software program (Geomagic Control; 3D Systems) was used to perform all the comparisons and superimpositions. The 3-way ANOVA test followed by the Tukey HSD test were used to assess precision and trueness. The 2-way ANOVA followed by the Tukey HSD test was used to assess scan time. The Pearson correlation test was performed between scan time and trueness for both scanners. An additional correlation was performed between scan time and number of images, as well as between number of images and trueness for the TRIOS 3. RESULTS Statistically significant influences of operator (P<.001), scanner (P<.001), scan size (P<.001), operator and scan size (P<.001), and scanner and scan size (P<.001) were observed. The TRIOS 3 group reported higher precision than the CEREC Omnicam group for complete-arch scans (P<.001), although no difference was observed for scans of the prepared tooth. Medium- (P=.002) and low-experience operators (P<.001) reported lower precision for complete-arch scans performed with CEREC Omnicam when compared with TRIOS 3. The low-experience operator reported significantly worse results for complete-arch scans in comparison with the medium- (P=.008 and P<.001) and high-experience operators (P<.001 and P=.001), by using TRIOS 3 and CEREC Omnicam, respectively. Medium- and high-experience operators reported similar results among themselves. The CEREC Omnicam scanner reported lower trueness for complete-arch scans when compared with the prepared tooth (P<.001); for TRIOS 3, a difference was only observed for the low-experience operator when compared with the high-experience operator (P<.001). The CEREC Omnicam reported lower trueness than the TRIOS 3, except for the medium-experience operator with the prepared tooth scan. Comparing the trueness between operators and considering the same scanner and scan size, all groups were similar. The low-experience operator had a longer scanning time than the medium- and high-experience operators. For TRIOS 3, the low-experience operator obtained the highest number of images during each scan. CONCLUSIONS The accuracy of intraoral scans was influenced by operator experience, type of IOSs, and scan size. More experienced operators and smaller scan sizes made for more accurate scans. In addition, more experienced operators made faster scans, and the TRIOS 3 was more accurate than the CEREC Omnicam for complete-arch scans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision
Ender, A., & Mehl, A. (2013) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(13)60028-1 · Cited by 622
Orthodontic measurements on digital study models compared with plaster models: a systematic review
Fleming, P., Marinho, V, & Johal, A. (2011) · Orthodontics & Craniofacial Research · doi:10.1111/j.1601-6343.2010.01503.x · Cited by 409
Comparison of experience curves between two 3-dimensional intraoral scanners
Kim, J., Park, J.-M., Kim, M., Heo, S.-J., Shin, I. H., & Kim, M. (2016) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2015.12.018 · Cited by 181
Comparison of accuracy and reproducibility of casts made by digital and conventional methods
Cho, S.-H., Schaefer, O., Thompson, G. A., & Guentsch, A. (2015) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2014.09.027 · Cited by 175
An, S., Kim, S., Choi, H., Lee, J. H., & Moon, H. (2014) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2013.12.024 · Cited by 113
Accuracy of 3-dimensional computer-aided manufactured single-tooth implant definitive casts
Buda, M., Bratos, M., & Sorensen, J. A. (2018) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2018.02.011 · Cited by 71
Cited by
Siqueira, R., Galli, M., Chen, Z., Mendonça, G., Meirelles, L., Wang, H.-L., & Chan, H.-L. (2021) · Clinical Oral Investigations · doi:10.1007/s00784-021-04157-3 · Cited by 200
“The level of operator experience was previously demonstrated to play an important role in IOS working time [44, 45].”
BackgroundSelf-citationParize, H., Dias Corpa Tardelli, J., Bohner, L., Sesma, N., Muglia, V. A., & Cândido dos Reis, A. (2022) · The Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2020.12.008 · Cited by 56
Metadata
- Authors
- Resende, C. C. D., Barbosa, T. A. Q., Moura, G. F., Tavares, L. D. N., Rizzante, F. A. P., George, F. M., Neves, F. D. D., & Mendonça, G.
- Venue
- The Journal of Prosthetic Dentistry
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 125
- Issue
- 2
- Pages
- 294-299
- ISSN
- 0022-3913 (ISSN-L)
- OpenAlex
- W3008972834
- Cited by
- 162
- References
- 6
- FWCI
- 20.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of operator experience, scanner type, and scan size on 3D scans. https://app.cochat.ai/papers/10.1016/j.prosdent.2019.12.011
- The paper
- Resende, C. C. D., Barbosa, T. A. Q., Moura, G. F., Tavares, L. D. N., Rizzante, F. A. P., George, F. M., Neves, F. D. D., & Mendonça, G. (2021). Influence of operator experience, scanner type, and scan size on 3D scans. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2019.12.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.