Accuracy of haptic robotic guidance of dental implant surgery for completely edentulous arches
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
STATEMENT OF PROBLEM The accuracy of single implant placement is critical, as errors may cause problems with vital structures intraoperatively, as well as postoperatively with the prostheses. These issues may be exacerbated in complete-arch edentulous treatments requiring relative accuracy among multiple implants, particularly with prefabricated prosthetic structures. PURPOSE The purpose of this clinical study was to determine the accuracy of dental implant placement by using haptic robotic guidance in completely edentulous participants. MATERIAL AND METHODS In a prospective single-arm clinical study, 5 qualified participants elected to receive dental implants placed by using haptic robotic guidance to restore either the maxillary or mandibular arch, or both, with complete-arch implant-supported prostheses. Three dual-arch participants and 2 single-arch participants resulted in 38 endosteal dental implants being placed. A virtual preoperative restorative and surgical plan was created before surgery. This plan was matched to the surgical workspace on the day of surgery by using a bone-mounted fiducial splint fabricated from a cone beam computed tomography (CBCT) scan. Intraoperatively, the surgeons maneuvered a handpiece attached to the robotic guidance arm, osteotomies were created with a haptically constrained handpiece, and the implants were placed with 3-dimensional haptic constraints as per the virtual plan. Postoperative CBCT scans allowed the evaluation of the deviations of the actual implant placement relative to the plan. RESULTS Twenty-three implants were placed in the mandible and 15 in the maxilla. The mean ±standard deviation global angular deviation was 2.56 ±1.48 degrees, while the crown of the placed implant showed a deviation from the plan of 1.04 ±0.70 mm and the apex of 0.95 ±0.73 mm. The signed depth deviation was 0.42 ±0.46 mm proud. No adverse events were reported. CONCLUSIONS This clinical series for treating completely edentulous patients by using haptic robotic guidance was found to be safe and accurate. While further longer-term clinical studies are necessary to measure outcomes and to assess differences as compared with nonrobotic implementations, haptic robotic preparation appears to confer additional intraoperative advantages over other techniques for treating completely edentulous arches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Metadata
- Authors
- Bolding, S. L., & Reebye, U. N.
- Venue
- The Journal of Prosthetic Dentistry
- Publisher
- Elsevier BV
- Published
- 2022-10
- Volume
- 128
- Issue
- 4
- Pages
- 639-647
- ISSN
- 0022-3913 (ISSN-L)
- OpenAlex
- W3134067743
- Cited by
- 163
- References
- 1
- FWCI
- 24.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of haptic robotic guidance of dental implant surgery for completely edentulous arches. https://app.cochat.ai/papers/10.1016/j.prosdent.2020.12.048
- The paper
- Bolding, S. L., & Reebye, U. N. (2022). Accuracy of haptic robotic guidance of dental implant surgery for completely edentulous arches. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2020.12.048
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.