Microbial-derived biosensors for monitoring environmental contaminants: Recent advances and future outlook
The DOI matches its Crossref record.
Abstract
Abstract Living cells have evolved to sense various environmental stimuli, thus presenting a novel platform to engineer bio-sensing devices. Owing to the ease of genetic modification and preservation, microorganisms have gained a special place as ideal host candidates. Moreover, microbial-derived biosensors are easy to use, inexpensive, compact, and portable. The unique structural and functional features rendering them exceptionally suitable for detection and monitoring of an array of environmentally-related pollutants. The manipulation of regulatory genes could upgrade a range of characteristic features of a biosensor such as sensitivity, selectivity and, target range. Contemporary uses of such genetically-microbe-based biosensors led to the fabrication of biosensors with unprecedented potentialities for monitoring environmental pollution. Herein, we reviewed the current advances in microbial-derived biosensors for monitoring environmentally-related contaminants. A particular emphasis is given to the improvement of genetically-engineered microbial biosensors and their application for environmental pollutants monitoring with up-to-date examples. Critical challenges including technical and societal are also highlighted to decipher the true perspective of microbial-derived biosensors for their widespread adoption and exploitation. Towards the end, the work is wrapped up with concluding remarks and future viewpoints to highlight the value of the microbial-derived biosensors, which could detect various pollutants or toxic compounds from a broader spectrum in the real-time, rapid and unique way with high sensitivity, and outstanding selectivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Liu, L., Bilal, M., Duan, X., & Iqbal, H. M. N. (2019) · Science of The Total Environment · doi:10.1016/j.scitotenv.2019.02.390 · Cited by 318
Self-citationRetractedHara, T. O., & Singh, B. (2021) · ACS ES&T Water · doi:10.1021/acsestwater.0c00125 · Cited by 252
Huang, C.-W., Lin, C., Nguyen, M. K., Hussain, A., Bui, X.-T., & Ngo, H. H. (2023) · Bioengineered · doi:10.1080/21655979.2022.2095089 · Cited by 227
“The mechanisms of bioluminescence-based inhibitory biosensors might be associated with the ATP reduction resulted from stress responsive mechanisms or cell death resulted from excessive environmental stress, which further decreased the bioluminescence by lower ATP and cell viability [17,66].”
BackgroundInfluentialRecent Trends in Biosensors for Environmental Quality Monitoring
Gavrilaș, S., Ursachi, C. Ș., Perța-Crișan, S., & Munteanu, F.-D. (2022) · Sensors · doi:10.3390/s22041513 · Cited by 202
“Numerous recent articles reported on the use of microbial biosensors to detect environmental pollutants, such as pesticides, heavy metals (As, Cu, Hg, Pb, or Cd), phenols, and other toxic compounds, using terrestrial and aquatic biota [15,19,71,72].”
BackgroundAlternative Strategies for Microbial Remediation of Pollutants via Synthetic Biology
Jaiswal, S., & Shukla, P. (2020) · Frontiers in Microbiology · doi:10.3389/fmicb.2020.00808 · Cited by 195
Metadata
- Authors
- Bilal, M., & Iqbal, H. M. N.
- Venue
- Process Safety and Environmental Protection
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 124
- Pages
- 8-17
- ISSN
- 0263-8762 (ISSN-L)
- 0957-5820
- OpenAlex
- W2912932887
- Cited by
- 119
- References
- 0
- FWCI
- 3.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microbial-derived biosensors for monitoring environmental contaminants: Recent advances and future outlook. https://app.cochat.ai/papers/10.1016/j.psep.2019.01.032
- The paper
- Bilal, M., & Iqbal, H. M. N. (2019). Microbial-derived biosensors for monitoring environmental contaminants: Recent advances and future outlook. Process Safety and Environmental Protection. https://doi.org/10.1016/j.psep.2019.01.032
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.