Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 237

The DOI matches its Crossref record.

The learning curve associated with a simulated ultrasound-guided interventional task by inexperienced anesthesia residents

SITES, B, GALLAGHER, J, CRAVERO, J, LUNDBERG, J, BLIKE, G · 2004 · Regional Anesthesia and Pain Medicine

Abstract

BACKGROUND AND OBJECTIVE: Ultrasound has become an increasingly popular modality in facilitating the performance of peripheral nerve blocks. There exists no literature that examines the learning curve of the ultrasound novice. In this prospective series, we evaluated the learning curve of inexperienced anesthesia residents in performing a simulated ultrasound-guided interventional procedure. In doing so, we hoped to identify reproducible patterns of human errors, which could potentially aid in the prevention of real-life iatrogenic injuries. METHODS: Ten subjects were prospectively enrolled. After a brief introduction to the ultrasound system, the subjects were asked to perform 6 sequential trials of a simulated breast cyst aspiration. For the first 3 trials, each subject attempted to place a 22-gauge b-bevel needle into any aspect of an olive buried inside the turkey breast. After completion of these 3 trials, the subjects were asked to place the needle into the exact midpoint of the olive wall closest to the transducer. Trials were videotaped and analyzed for task performance in terms of speed and accuracy. RESULTS: All subjects successfully completed the 6 interventional trials. The mean time to perform the task was reduced by 38% and 48%, respectively, for the second and third trials. A composite score of accuracy showed an improvement of 36% and 59%, respectively, for the second and third trials. The most common committed error, which occurred in 7 of 10 subjects, was the failure to accurately image the needle while advancing. This resulted in excessive depth of penetration and inadvertent transfixation of the olive in 5 of these subjects. CONCLUSIONS: Anesthesiology residents, with little or no ultrasound experience, can rapidly learn and improve their speed and accuracy in performing a simulated interventional ultrasound procedure. A concerning novice pattern was identified where the subjects advanced the needle even though it was not appropriately visualized in the ultrasound beam. This resulted in needle placement error, which could cause iatrogenic injury in the clinical setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.rapm.2004.08.014

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
SITES, B., GALLAGHER, J., CRAVERO, J., LUNDBERG, J., & BLIKE, G.
Venue
Regional Anesthesia and Pain Medicine
Publisher
BMJ
Published
2004-12
Volume
29
Issue
6
Pages
544-548
ISSN
1098-7339 (ISSN-L)
OpenAlex
W2080313660
Cited by
237
References
0
FWCI
8.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.