Experimental evaluation at pilot plant scale of multiple PCMs (cascaded) vs. single PCM configuration for thermal energy storage
Open accessAbstract
The present paper provides on one hand, a literature review of the different studies available in the scientific literature where the concept of multiple phase change materials (PCM) configuration, also named cascaded or multi-stage, has been presented and on the other hand, an experimental evaluation of the advantages of using the multiple PCM configuration instead of the single PCM configuration in thermal energy storage (TES) systems at pilot plant to fill the gap of experimental and high scales studies on this concept in the literature. Two PCM with melting temperatures in a temperature range of 150–200 °C were selected due to their high value of heat of fusion and compared: d-mannitol and hydroquinone. Three configurations were evaluated: (1) single PCM with hydroquinone, (2) single PCM with d-mannitol and (3) multiple PCM with hydroquinone and d-mannitol. A discussion regarding the results on the specific energy stored and effectiveness as well as the evolution of the PCM and heat transfer fluid (HTF) through the time and at different and representative locations of the facility is presented. Results showed that the multiple PCMs configuration introduced an effectiveness enhancement of 19.36% if compared with single PCM configuration as well as a higher uniformity on the HTF temperature difference between the inlet and outlet.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Thermal energy storage: Recent developments and practical aspects
Zhang, H., Baeyens, J., Cáceres, G., Degrève, J., & Lv, Y. (2016) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2015.10.003 · Cited by 910
A review of phase change material and performance enhancement method for latent heat storage system
Tao, Y. B., & He, Y.-L. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.05.028 · Cited by 633
Ibrahim, N. I., Al-Sulaiman, F. A., Rahman, S., Yilbas, B. S., & Sahin, A. Z. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.01.169 · Cited by 580
Electric vehicles batteries thermal management systems employing phase change materials
Ianniciello, L., Biwolé, P. H., & Achard, P. (2018) · Journal of Power Sources · doi:10.1016/j.jpowsour.2017.12.071 · Cited by 426
Pandey, A. K., Hossain, M. S., Tyagi, V. V., Abd Rahim, N., Selvaraj, J. A. /., & Sari, A. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.043 · Cited by 423
Metadata
- Authors
- Peiró, G., Gasia, J., Miró, L., & Cabeza, L. F.
- Venue
- Renewable Energy
- Publisher
- Elsevier BV
- Published
- 2015-11
- Volume
- 83
- Pages
- 729-736
- ISSN
- 0960-1481 (ISSN-L)
- OpenAlex
- W400873174
- Cited by
- 211
- References
- 0
- FWCI
- 15.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental evaluation at pilot plant scale of multiple PCMs (cascaded) vs. single PCM configuration for thermal energy storage. https://app.cochat.ai/papers/10.1016/j.renene.2015.05.029
- The paper
- Peiró, G., Gasia, J., Miró, L., & Cabeza, L. F. (2015). Experimental evaluation at pilot plant scale of multiple PCMs (cascaded) vs. single PCM configuration for thermal energy storage. Renewable Energy. https://doi.org/10.1016/j.renene.2015.05.029
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.