Application of nanofluid to improve the thermal performance of horizontal spiral coil utilized in solar ponds: Geometric study
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Abstract Today, one of the most common methods for heat extraction from the solar ponds is using spiral piping system. In this study, effects of nanofluid concentrations and different cross-sections of tube on thermal performance of horizontal spiral-coil in laminar fluid flow are investigated numerically. Water-graphene nanoplatelet/platinum hybrid nanofluid with 0.02, 0.06 and 0.10% volume concentration has used as working fluid. Simulations are performed for different mass flow rates between 0.0005 and 0.005 kg/s. Different shapes including rectangle, elliptic, trapezoid and circle are selected as tube cross-sections. Uniform temperature and velocity distributions with several mass flow rates are applied to geometry at inlet and constant wall temperature as boundary conditions. The results show that variations of average Nusselt number in lower mass flow rates is not dependent to the shape of flow cross-section. By increasing the nanoparticles concentration, the highest Nusselt number belongs to tube with elliptical cross-section. Surfaces with angular corners create greater velocity variations in comparison with surfaces with curved corners and this behavior leads to higher pressure loss as well as more pumping power. Also, by increasing mass flow rate, the heat transfer between hot surfaces and cooling fluid is enhanced. The highest and lowest values of outlet temperature are reported for fluid with highest solid nanoparticle volume concentration and distilled water, respectively. Among the considered mass flow rates in φ = 0.06 and 0.10%, mass flow rate of 0.002 kg/s has the highest thermo-fluid efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Experimental studies on the applications of PCMs and nano-PCMs in buildings: A critical review
Kasaeian, A., bahrami, L., Pourfayaz, F., Khodabandeh, E., & Yan, W.-M. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.08.037 · Cited by 287
Self-citation
Cited by
Combined “Renewable Energy–Thermal Energy Storage (RE–TES)” Systems: A Review
Elkhatat, A., & Al-Muhtaseb, S. A. (2023) · Energies · doi:10.3390/en16114471 · Cited by 100
Metadata
- Authors
- Khodabandeh, E., Safaei, M. R., Akbari, S., Akbari, O. A., & Alrashed, A. A. A. A.
- Venue
- Renewable Energy
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 122
- Pages
- 1-16
- ISSN
- 0960-1481 (ISSN-L)
- OpenAlex
- W2790112374
- Cited by
- 160
- References
- 1
- FWCI
- 9.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of nanofluid to improve the thermal performance of horizontal spiral coil utilized in solar ponds: Geometric study. https://app.cochat.ai/papers/10.1016/j.renene.2018.01.023
- The paper
- Khodabandeh, E., Safaei, M. R., Akbari, S., Akbari, O. A., & Alrashed, A. A. A. A. (2018). Application of nanofluid to improve the thermal performance of horizontal spiral coil utilized in solar ponds: Geometric study. Renewable Energy. https://doi.org/10.1016/j.renene.2018.01.023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.