Abstract
This study investigates how a district with a high capacity of non-controllable renewable electricity generation can entirely self-consume its production at a community level either directly or for heating and cooling, thus potentially fulfilling the concept of "Renewable Energy Community". It investigates the potential role of storage systems and polygeneration in renewables self-consumption, by also exploiting the synergies among different energy networks in a real residential district with high PV penetration. Two scenarios were modeled other than the "baseline": the first one evaluating the optimal portfolio of energy conversion and storage technologies, and a second one achieving the same goal only using batteries. Both scenarios proved to be a viable solution to exploit the excess of electricity production from the PV plants in the district only through local self-consumption. The results show that a multi-energy system is the most cost-effective solution in doing so, exploiting polygeneration technologies (CHP) and the storage of energy as thermal, electrical, and chemical through power-to-gas. In particular, the least cost solution entails a 42 kWe CHP micro gas engine fueled by a natural gas-hydrogen blend, a 135 kWh battery system, and a 2830 kWh hydrogen storage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buttler, A., & Spliethoff, H. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.003 · Cited by 2,510
Schiebahn, S., Grube, T., Robinius, M., Tietze, V., Kumar, B., & Stolten, D. (2015) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2015.01.123 · Cited by 823
Distributed multi-generation: A comprehensive view
Chicco, G., & Mancarella, P. (2008) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2007.11.014 · Cited by 803
Energy hub: From a model to a concept – A review
Mohammadi, M., Noorollahi, Y., Mohammadi‐Ivatloo, B., & Yousefi, H. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.030 · Cited by 546
Hoppmann, J., Volland, J., Schmidt, T. S., & Hoffmann, V. H. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.07.068 · Cited by 531
Comparison of electricity storage options using levelized cost of storage (LCOS) method
Jülch, V. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.08.165 · Cited by 492
Smart operations of smart grids integrated with distributed generation: A review
Kakran, S., & Chanana, S. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.045 · Cited by 427
Pfenninger, S. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.03.051 · Cited by 367
Microgrid sizing with combined evolutionary algorithm and MILP unit commitment
Li, B., Roche, R., & Miraoui, A. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.12.038 · Cited by 307
Role of power-to-gas in an integrated gas and electricity system in Great Britain
Qadrdan, M., Abeysekera, M., Chaudry, M., Wu, J., & Jenkins, N. (2015) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2015.03.004 · Cited by 298
Robledo, C. B., Oldenbroek, V., Abbruzzese, F., & van Wijk, A. J. M. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.02.038 · Cited by 284
Community energy storage: A smart choice for the smart grid?
Barbour, E., Parra, D., Awwad, Z., & González, M. C. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.056 · Cited by 239
Use of model predictive control for experimental microgrid optimization
Parisio, A., Rikos, E., Tzamalis, G., & Glielmo, L. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.10.027 · Cited by 223
Yan, F., Xu, L., & Wang, Y. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.227 · Cited by 193
Modeling and optimal operation of community integrated energy systems: A case study from China
Wang, C., Lv, C., Li, P., Song, G., Li, S., Xu, X., & Wu, J. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.09.042 · Cited by 177
Ahmad, F., Alam, M. S., & Asaad, M. (2017) · Sustainable Cities and Society · doi:10.1016/j.scs.2017.09.008 · Cited by 144
Hafiz, F., de Queiroz, A. R., Fajri, P., & Husain, I. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.11.080 · Cited by 140
A renewable source based hydrogen energy system for residential applications
Sorgulu, F., & Dinçer, İ. (2017) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2017.10.101 · Cited by 140
Kavadias, K. A., Apostolou, D., & Kaldellis, J. K. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.08.050 · Cited by 126
Terlouw, T., AlSkaif, T. A., Bauer, C., & van Sark, W. G. J. H. M. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.113580 · Cited by 104
Murray, P., Orehounig, K., Grosspietsch, D., & Carmeliet, J. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.08.106 · Cited by 94
Haghi, E., Raahemifar, K., & Fowler, M. W. (2017) · Energy Policy · doi:10.1016/j.enpol.2017.10.045 · Cited by 93
Study on Early Business Cases for H2 In Energy Storage and More Broadly Power to H2 Applications
Undertaking, F. C. A. H. J. (2017) · Cited by 90
Analysis of component operation in power-to-gas-to-power installations
Kotowicz, J., Węcel, D., & Jurczyk, M. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.02.050 · Cited by 78
Ten questions concerning smart districts
Good, N., Ceseña, E. A. M., & Mancarella, P. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.03.037 · Cited by 67
National Renewable Energy Lab. (NREL), G., Denholm, P. L., Solar Energy Technologies Office (EE-4S) USDOE Office of Energy Efficiency and Renewable Energy (EERE), Clark, K., & O’Connell, M. (2016) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1253978 · Cited by 54
Bailera, M., Peña, B., Lisbona, P., & Romeo, L. M. (2018) · Applied Energy · doi:10.1016/j.apenergy.2018.06.128 · Cited by 53
Cited by
A critical review of the integration of renewable energy sources with various technologies
Erdiwansyah, Mahidin, Husin, H., Nasaruddin, Zaki, M., & Muhibbuddin (2021) · Protection and Control of Modern Power Systems · doi:10.1186/s41601-021-00181-3 · Cited by 473
“[17, 128] Lithium (Li)-Battery with lead-acid Handed out storage Self-consumption optimisation, peak shaving, power balancing, maximum load provision Housing equipment distributed in household, commercial or small industrial environments”
BackgroundZhou, Y. (2024) · Journal of Energy Storage · doi:10.1016/j.est.2024.113688 · Cited by 42
Metadata
- Authors
- Bartolini, A., Carducci, F., Muñoz, C. B., & Comodi, G.
- Venue
- Renewable Energy
- Publisher
- Elsevier BV
- Published
- 2020-10
- Volume
- 159
- Pages
- 595-609
- ISSN
- 0960-1481 (ISSN-L)
- OpenAlex
- W3033604839
- Cited by
- 204
- References
- 27
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.