The DOI matches its Crossref record.
Capnography during cardiac arrest
Abstract
Successful resuscitation from cardiac arrest depends on provision of adequate blood flow to vital organs generated by cardiopulmonary resuscitation (CPR). Measurement of end-tidal expiratory pressure of carbon dioxide (ETCO2) using capnography provides a noninvasive estimate of cardiac output and organ perfusion during cardiac arrest and can therefore be used to monitor the quality of CPR and predict return of spontaneous circulation (ROSC). In clinical observational studies, mean ETCO2 levels in patients with ROSC are higher than those in patients with no ROSC. In prolonged out of hospital cardiac arrest, ETCO2 levels <10 mmHg are consistently associated with a poor outcome, while levels above this threshold have been suggested as a criterion for considering patients for rescue extracorporeal resuscitation. An abrupt rise of ETCO2 during CPR suggests that ROSC has occurred. Finally, detection of CO2 in exhaled air following intubation is the most specific criterion for confirming endotracheal tube placement during CPR. The aetiology of cardiac arrest, variations in ventilation patterns during CPR, and the effects of drugs such as adrenaline or sodium bicarbonate administered as a bolus may significantly affect ETCO2 levels and its clinical significance. While identifying ETCO2 as a useful monitoring tool during resuscitation, current guidelines for advanced life support recommend against using ETCO2 values in isolation for decision making in cardiac arrestmanagement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Panchal, A. R., Bartos, J. A., Cabañas, J. G., Donnino, M. W., Drennan, I. R., Hirsch, K. G., Kudenchuk, P. J., Kurz, M. C., Lavonas, E. J., Morley, P. T., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000916 · Cited by 2,105
Topjian, A. A., Raymond, T. T., Atkins, D., Chan, M., Duff, J. P., Joyner, B. L., Lasa, J. J., Lavonas, E. J., Levy, A., Mahgoub, M., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000901 · Cited by 1,258
European Resuscitation Council Guidelines 2021: Adult advanced life support
Soar, J., Böttiger, B. W., Carli, P., Couper, K., Deakin, C. D., Djärv, T., Lott, C., Olasveengen, T., Paal, P., Pellis, T., et al. (2021) · Resuscitation · doi:10.1016/j.resuscitation.2021.02.010 · Cited by 1,225
Self-citationMadar, J., Roehr, C. C., Ainsworth, S., Ersdal, H., Morley, C., Rüdiger, M., Skåre, C., Szczapa, T., te Pas, A., Trevisanuto, D., et al. (2021) · Resuscitation · doi:10.1016/j.resuscitation.2021.02.014 · Cited by 524
Klein, A. A., Meek, T., Allcock, E., Cook, T. M., Mincher, N., Morris, C., Nimmo, A. F., Pandit, J. J., Pawa, A., Rodney, G., et al. (2021) · Anaesthesia · doi:10.1111/anae.15501 · Cited by 340
Metadata
- Authors
- Sandroni, C., De Santis, P., & D’Arrigo, S.
- Venue
- Resuscitation
- Publisher
- Elsevier BV
- Published
- 2018-11
- Volume
- 132
- Pages
- 73-77
- ISSN
- 0300-9572 (ISSN-L)
- OpenAlex
- W2888192440
- Cited by
- 171
- References
- 0
- FWCI
- 16.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capnography during cardiac arrest. https://app.cochat.ai/papers/10.1016/j.resuscitation.2018.08.018
- The paper
- Sandroni, C., De Santis, P., & D’Arrigo, S. (2018). Capnography during cardiac arrest. Resuscitation. https://doi.org/10.1016/j.resuscitation.2018.08.018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.