Exploration of strategies to reduce aerosol-spread during chest compressions: A simulation and cadaver model
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objective To evaluate the effect of strategies to reduce the spread of simulated aerosol during chest compressions on manikin and cadaver experimental models. Methods To evaluate aerosol-spread we nebulized ultraviolet sensitive detergents into the artificial airway of a resuscitation dummy and performed CPR. The spread of the visualized aerosol was documented by a camera. In a further approach we applied nebulized detergents into the airways of human cadavers and detected the simulated spread on the same way. Among others we did recordings with undergoing compression-only-CPR, with a surgical mask or an oxygen mask on the patients face and with an inserted supraglottic airway device with and without a connected airway filter. Results Most aerosol-spread at the direction of the provider was visualized during compression-only-CPR. The use of a surgical mask and of an oxygen mask on the patient's face deflected the spread. Inserting a supraglottic airway device connected to an airway filter lead to a remarkable reduction of aerosol-spread. Conclusion The early insertion of a supraglottic airway device connected to an airway filter before starting chest compression may be beneficial for staff protection during CPR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ruan, Q., Yang, K., Wang, W., Jiang, L., & Song, J. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-05991-x · Cited by 4,898
Coronavirus disease 2019 (COVID-19) in Italy
Livingston, E., & Bucher, K. (2020) · JAMA · doi:10.1001/jama.2020.4344 · Cited by 1,010
Cited by
European Resuscitation Council Guidelines 2021: Executive summary
Perkins, G. D., Gräsner, J.-T., Semeraro, F., Olasveengen, T., Soar, J., Lott, C., Van de Voorde, P., Madar, J., Zideman, D., Mentzelopoulos, S., et al. (2021) · Resuscitation · doi:10.1016/j.resuscitation.2021.02.003 · Cited by 649
“these reviews, the search strategies have been re-run and a further four articles identified.(70) 74 None of the new articles contained information sufficient to change the previous treatment recommendations.”
BackgroundEuropean Resuscitation Council COVID-19 guidelines executive summary
Nolan, J. P., Monsieurs, K. G., Bossaert, L., Böttiger, B. W., Greif, R., Lott, C., Madar, J., Olasveengen, T. M., Roehr, C. C., Semeraro, F., et al. (2020) · Resuscitation · doi:10.1016/j.resuscitation.2020.06.001 · Cited by 347
“Aerosol generation by chest compressions is plausible because they generate small but measurable tidal volumes.(25,26) Chest compressions are similar to some chest physiotherapy techniques, which are associated with aerosol generation.”
BackgroundSafety and Efficacy of Chest Physiotherapy in Patients With COVID-19: A Critical Review
Abdullahi, A. (2020) · Frontiers in Medicine · doi:10.3389/fmed.2020.00454 · Cited by 79
Metadata
- Authors
- Ott, M., Milazzo, A., Liebau, S., Jaki, C., Schilling, T., Krohn, A., & Heymer, J.
- Venue
- Resuscitation
- Publisher
- Elsevier BV
- Published
- 2020-07
- Volume
- 152
- Pages
- 192-198
- ISSN
- 0300-9572 (ISSN-L)
- OpenAlex
- W3021828647
- Cited by
- 58
- References
- 2
- FWCI
- 6.28
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Exploration of strategies to reduce aerosol-spread during chest compressions: A simulation and cadaver model. https://app.cochat.ai/papers/10.1016/j.resuscitation.2020.05.012
- The paper
- Ott, M., Milazzo, A., Liebau, S., Jaki, C., Schilling, T., Krohn, A., & Heymer, J. (2020). Exploration of strategies to reduce aerosol-spread during chest compressions: A simulation and cadaver model. Resuscitation. https://doi.org/10.1016/j.resuscitation.2020.05.012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.