Choosing inhaler devices for people with asthma: Current knowledge and outstanding research needs
Open accessAbstract
Recommendations in asthma guidelines presuppose that practitioners have the evidence, information, knowledge, and tools to select inhaler devices appropriate for individual patients. Randomised controlled trials usually exclude patients with suboptimal inhaler technique. There is therefore little evidence on which to base inhaler selection in the real world, where patients often use their inhalers incorrectly. The lung deposition of inhaled drug varies according to inhaler device, drug particle size, inhalation technique, and pattern of inspiratory flow. Even with training, not all patients can use their inhalers correctly and maintain inhaler technique; patients may have inability to handle the inhaler, strong negative preferences, or natural breathing patterns that do not match their prescribed inhaler. Therefore, matching device to the patient may be a better course of action than increasing therapy or training and retraining a patient to use a specific inhaler device. Several research questions require answers to meet the goal of helping prescribers make a more informed choice of inhaler type. Is the level of drug deposition in the lungs a key determinant of clinical short- and long-term outcomes? What should be measured by a clinical tool designed to check inhaler technique and therefore help with device selection? If we have a tool to help in individualising inhaler choice, will we achieve better asthma outcomes? Do we have to refine inhaler device choice for each individual, or will we get better outcomes if we select our current best option in light of current knowledge and apply this on a population level?
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Deposition of 80% of the drug in the oropharynx changes treatment effectiveness and can cause local or systemic side effects.
“which considerably changes the effectiveness of the treatment and can cause local or systemic side effects [55,69].”
From Drugs Prescribed for Asthma and Their Adverse Effects on Dental Health (2023) · cites this paper as [69]
Inadequate inhalation technique triggers 80% of the drug to be deposited in the oropharynx.
“triggering 80% of the drug to be deposited in the oropharynx”
From Drugs Prescribed for Asthma and Their Adverse Effects on Dental Health (2023) · cites this paper as [69]
Almost 30% of asthmatic adults have an inadequate inhalation technique.
“almost 30% of asthmatic adults have an inadequate inhalation technique”
From Drugs Prescribed for Asthma and Their Adverse Effects on Dental Health (2023) · cites this paper as [69]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 56
- Sestini, 2006, Prescription bias and factors associated with improper use of inhalers, J Aerosol Med, 19, 127, 10.1089/jam.2006.19.127 · DOI
- Haughney, 2008, Achieving asthma control in practice: understanding the reasons for poor control, Respir Med, 102, 1681, 10.1016/j.rmed.2008.08.003 · DOI
- Horne, 2007, Can asthma control be improved by understanding the patient’s perspective?, BMC Pulm Med, 7, 8, 10.1186/1471-2466-7-8 · DOI
- Brocklebank, 2001, Comparison of the effectiveness of inhaler devices in asthma and chronic obstructive airways disease: a systematic review of the literature, Health Technol Assess, 5, 1, 10.3310/hta5260 · DOI
- Brocklebank, 2001, Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering corticosteroids in asthma, BMJ, 323, 896, 10.1136/bmj.323.7318.896 · DOI
- Dolovich, 2005, Device selection and outcomes of aerosol therapy: Evidence-based guidelines: American College of Chest Physicians/American College of Asthma, Allergy, and Immunology, Chest, 127, 335, 10.1378/chest.127.1.335 · DOI
- Cochrane, 2000, Inhaled corticosteroids for asthma therapy: patient compliance, devices, and inhalation technique, Chest, 117, 542, 10.1378/chest.117.2.542 · DOI
- Lavorini, 2008, Effect of incorrect use of dry powder inhalers on management of patients with asthma and COPD, Respir Med, 102, 593, 10.1016/j.rmed.2007.11.003 · DOI
- Molimard, 2003, Assessment of handling of inhaler devices in real life: An observational study in 3811 patients in primary care, J Aerosol Med, 16, 249, 10.1089/089426803769017613 · DOI
- Lenney, 2000, Inappropriate inhaler use: assessment of use and patient preference of seven inhalation devices. EDICI, Respir Med, 94, 496, 10.1053/rmed.1999.0767 · DOI
- Schulte, 2008, Handling of and preferences for available dry powder inhaler systems by patients with asthma and COPD, J Aerosol Med Pulm Drug Deliv, 21, 321, 10.1089/jamp.2007.0634 · DOI
- Hardwell, 2009, Technique training does not improve the ability of most patients to use pressurised Metered Dose Inhalers (pMDI), Prim Care Respir J, 18, A1
- Newman, 1991, Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique, Thorax, 46, 712, 10.1136/thx.46.10.712 · DOI
- Lahdensuo, 1986, Bronchodilator effects of a fenoterol metered dose inhaler and fenoterol powder in asthmatics with poor inhaler technique, Eur J Respir Dis, 68, 332
- Lindgren, 1987, Clinical consequences of inadequate inhalation technique in asthma therapy, Eur J Respir Dis, 70, 93
- Giraud, 2002, Misuse of corticosteroid metered-dose inhaler is associated with decreased asthma stability, Eur Respir J, 19, 246, 10.1183/09031936.02.00218402 · DOI
- Khassawneh, 2008, Handling of inhaler devices in actual pulmonary practice: metered-dose inhaler versus dry powder inhalers, Respir Care, 53, 324
- van der Palen, 1999, Multiple inhalers confuse asthma patients, Eur Respir J, 14, 1034, 10.1183/09031936.99.14510349 · DOI
- Thomas, 2009, Inhaled corticosteroids for asthma: impact of practice level device switching on asthma control, BMC Pulm Med, 9, 1, 10.1186/1471-2466-9-1 · DOI
- Kemp, 2009, ‘Real-Life’ Effectiveness of Qvar, Beclomethasone and Fluticasone, J Allergy Clin Immunol, 123, 6, 10.1016/j.jaci.2009.01.027 · DOI
- Price, 2003, Improvement of asthma control with a breath-actuated pressurised metred dose inhaler (BAI): a prescribing claims study of 5556 patients using a traditional pressurised metred dose inhaler (MDI) or a breath-actuated device, Respir Med, 97, 12, 10.1053/rmed.2002.1426 · DOI
- Leach, 2002, Lung deposition of hydrofluoroalkane-134a beclomethasone is greater than that of chlorofluorocarbon fluticasone and chlorofluorocarbon beclomethasone: a cross-over study in healthy volunteers, Chest, 122, 510, 10.1378/chest.122.2.510 · DOI
- Carstairs, 1985, Autoradiographic visualization of beta-adrenoceptor subtypes in human lung, Am Rev Respir Dis, 132, 541
- Mak, 1990, Autoradiographic visualization of muscarinic receptor subtypes in human and guinea pig lung, Am Rev Respir Dis, 141, 1559, 10.1164/ajrccm/141.6.1559 · DOI
- Hamid, 1997, Inflammation of small airways in asthma, J Allergy Clin Immunol, 100, 44, 10.1016/S0091-6749(97)70193-3 · DOI
- Tulic, 2006, New insights into the pathophysiology of the small airways in asthma, Clin Chest Med, 27, 41, 10.1016/j.ccm.2005.10.007 · DOI
- Chrystyn, 1999, Anatomy and physiology in delivery: can we define our targets?, Allergy, 54, 82, 10.1111/j.1398-9995.1999.tb04393.x · DOI
- Usmani, 2005, Regional lung deposition and bronchodilator response as a function of beta2-agonist particle size, Am J Respir Crit Care Med, 172, 1497, 10.1164/rccm.200410-1414OC · DOI
- Al-Showair, 2007, The potential of a 2Tone Trainer to help patients use their metered-dose inhalers, Chest, 131, 1776, 10.1378/chest.06-2765 · DOI
- Juniper, 2002, Chest, 121, 1824, 10.1378/chest.121.6.1824 · DOI
- Martin, 2008, Exploring the distal lung: new direction in asthma, Isr Med Assoc J, 10, 846
- Leach, 1998, Improved airway targeting with the CFC-free HFA-beclomethasone metered-dose inhaler compared with CFC-beclomethasone, Eur Respir J, 12, 1346, 10.1183/09031936.98.12061346 · DOI
- Busse, 1999, Efficacy response of inhaled beclomethasone dipropionate in asthma is proportional to dose and is improved by formulation with a new propellant, J Allergy Clin Immunol, 104, 1215, 10.1016/S0091-6749(99)70016-3 · DOI
- Self, 2009, Does it really matter what volume to exhale before using asthma inhalation devices?, J Asthma, 46, 212, 10.1080/02770900802492087 · DOI
- Newman, 1982, Effects of various inhalation modes on the deposition of radioactive pressurized aerosols, Eur J Respir Dis Suppl, 119, 57
- Pauwels, 1997, Airway deposition and airway effects of antiasthma drugs delivered from metered-dose inhalers, Eur Respir J, 10, 2127, 10.1183/09031936.97.10092127 · DOI
- Tomlinson, 2005, Assessment of different methods of inhalation from salbutamol metered dose inhalers by urinary drug excretion and methacholine challenge, Br J Clin Pharmacol, 60, 605, 10.1111/j.1365-2125.2005.02499.x · DOI
- Hesselink, 2001, Determinants of an incorrect inhalation technique in patients with asthma or COPD, Scand J Prim Health Care, 19, 255, 10.1080/02813430152706792 · DOI
- Nimmo, 1993, Assessment of patient acceptance and inhalation technique of a pressurized aerosol inhaler and two breath-actuated devices, Ann Pharmacother, 27, 922, 10.1177/106002809302700721 · DOI
- Clark, 1993, The relationship between powder inhaler resistance and peak inspiratory conditions in healthy volunteers–implications for in vitro testing, J Aerosol Med, 6, 99, 10.1089/jam.1993.6.99 · DOI
- Chrystyn, 2009, What you need to know about inhalers and how to use them, Prescriber, 20, 47, 10.1002/psb.529 · DOI
- Broeders, 2001, Peak inspiratory flow rate and slope of the inhalation profiles in dry powder inhalers, Eur Respir J, 18, 780, 10.1183/13993003/erj.18.5.780 · DOI
- Weuthen, 2002, In vitro testing of two formoterol dry powder inhalers at different flow rates, J Aerosol Med, 15, 297, 10.1089/089426802760292636 · DOI
- Palander, 2000, In vitro comparison of three salbutamol-containing multidose dry powder inhalers: Buventol Easyhaler(R), Inspiryl Turbuhaler(R) and Ventoline Diskus(R), Clin Drug Investig, 20, 25, 10.2165/00044011-200020010-00004 · DOI
- Borgstrom, 1994, Lung deposition of budesonide inhaled via Turbuhaler: a comparison with terbutaline sulphate in normal subjects, Eur Respir J, 7, 69, 10.1183/09031936.94.07010069 · DOI
- Newman, 1991, Terbutaline sulphate Turbuhaler: effect of inhaled flow rate on drug deposition and efficacy, Int J Pharm, 74, 209, 10.1016/0378-5173(91)90239-K · DOI
- Bisgaard, 1998, Fine particle mass from the Diskus inhaler and Turbuhaler inhaler in children with asthma, Eur Respir J, 11, 1111, 10.1183/09031936.98.11051111 · DOI
- Broeders, 2005, Ventolin Diskus and Inspyril Turbuhaler: an in vitro comparison, J Aerosol Med, 18, 74, 10.1089/jam.2005.18.74 · DOI
- Tarsin, 2006, Emitted dose estimates from Seretide Diskus and Symbicort Turbuhaler following inhalation by severe asthmatics, Int J Pharm, 316, 131, 10.1016/j.ijpharm.2006.02.040 · DOI
- Diamond, 2001, The impact of a nationally coordinated pharmacy-based asthma education intervention, Can Respir J, 8, 261
- Janson, 2009, Individualized asthma self-management improves medication adherence and markers of asthma control, J Allergy Clin Immunol, 123, 840, 10.1016/j.jaci.2009.01.053 · DOI
- Basheti, 2008, Evaluation of a novel educational strategy, including inhaler-based reminder labels, to improve asthma inhaler technique, Patient Educ Couns, 72, 26, 10.1016/j.pec.2008.01.014 · DOI
- Newman, 1991, Salbutamol aerosol delivery in man with the Rondo-Spacer, Acta Ther, 17, 49
- Mazhar, 2008, Salbutamol relative lung and systemic bioavailability of large and small spacers, J Pharm Pharmacol, 60, 1609, 10.1211/jpp.60.12.0006 · DOI
- Ronmark, 2005, Correct use of three powder inhalers: comparison between Diskus, Turbuhaler, and Easyhaler, J Asthma, 42, 173, 10.1081/JAS-54629 · DOI
- Chrystyn, 2003, Is inhalation rate important for a dry powder inhaler? Using the In-Check Dial to identify these rates, Respir Med, 97, 181, 10.1053/rmed.2003.1351 · DOI
Cited by
Sorted by citations
Drugs Prescribed for Asthma and Their Adverse Effects on Dental Health
Pacheco-Quito, E.-M., Jaramillo, J., Sarmiento-Ordoñez, J., & Cuenca-León, K. (2023) · Dentistry Journal · doi:10.3390/dj11050113 · Cited by 33
Metadata
- Authors
- Haughney, J., Price, D., Barnes, N. C., Virchow, J. C., Roche, N., & Chrystyn, H.
- Affiliations
- University of Aberdeen (GB)
- London Chest Hospital (GB)
- Universitätsmedizin Rostock (DE)
- University of Huddersfield (GB)
- Corresponding author
- Haughney, John
- Price, David
- Barnes, Neil C.
- Virchow, J. Christian
- Chrystyn, Henry
- Venue
- Respiratory Medicine
- Publisher
- Elsevier BV
- Published
- 2010-09
- Volume
- 104
- Issue
- 9
- Pages
- 1237-1245
- ISSN
- 0954-6111 (ISSN-L)
- OpenAlex
- W2168551021
- Cited by
- 190
- References
- 0
- Citations by year
- 2026: 6 · 2025: 4 · 2024: 13 · 2023: 9 · 2022: 8 · 2021: 9 · 2020: 15 · 2019: 19 · 2018: 17 · 2017: 20 · 2016: 14 · 2015: 14 · 2014: 13 · 2013: 11 · 2012: 7
- FWCI
- 1.64
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Respiratory Medicine (publishedVersion)
- PubMed (publishedVersion)
- University of Huddersfield Repository (University of Huddersfield) (submittedVersion)
- Funders
- Mundipharma International
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Asthma and respiratory diseases
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Keywords
- asthma, inhaler devices, inhaler selection, inhaler technique, lung deposition, pulmonary drug delivery, personalized treatment, patient preferences, drug particle size
- MeSH terms
- Asthma, Dose-Response Relationship, Drug, Humans, Nebulizers and Vaporizers, Particle Size, Patient Selection, Anti-Asthmatic Agents, Needs Assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review