The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
A review on desiccant based evaporative cooling systems
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Removing latent heat from indoor environments through dehumidification is an essential and important method, especially in hot and humid climates, to reduce cooling load and increase human comfort [251].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [251]
Citations
Cites
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092
Energy Information Administration
(2007) · Choice Reviews Online · doi:10.5860/choice.44-3624 · Cited by 2,490
Demographic trends and energy consumption in European Union Nations, 1960–2025
York, R. (2007) · Social Science Research · doi:10.1016/j.ssresearch.2006.06.007 · Cited by 440
An experimental study of a novel dew point evaporative cooling system
Riangvilaikul, B., & Kumar, S. (2009) · Energy and Buildings · doi:10.1016/j.enbuild.2009.10.034 · Cited by 413
Zhan, C., Duan, Z., Zhao, X., Smith, S., Jin, H., & Riffat, S. (2011) · Energy · doi:10.1016/j.energy.2011.10.019 · Cited by 245
Heidarinejad, G., Bozorgmehr, M., Delfani, S., & Esmaeelian, J. (2009) · Building and Environment · doi:10.1016/j.buildenv.2009.02.017 · Cited by 235
Numerical study of a novel counter-flow heat and mass exchanger for dew point evaporative cooling
Zhao, X., Li, J. M., & Riffat, S. (2008) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2007.12.006 · Cited by 231
Numerical study of a novel dew point evaporative cooling system
Riangvilaikul, B., & Kumar, S. (2010) · Energy and Buildings · doi:10.1016/j.enbuild.2010.07.020 · Cited by 227
Jones, W. P. (2007) · Routledge eBooks · doi:10.4324/9780080498942 · Cited by 220
Evaporative Air Conditioning Handbook
Watt, J. R. (1986) · Springer eBooks · doi:10.1007/978-1-4613-2259-7 · Cited by 209
Comparative study of heat and mass exchanging materials for indirect evaporative cooling systems
Zhao, X., Liu, S., & Riffat, S. (2007) · Building and Environment · doi:10.1016/j.buildenv.2007.11.009 · Cited by 201
A review of the mathematical models for predicting rotary desiccant wheel
Ge, T., Li, Y., Wang, R. Z., & Dai, Y. (2007) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2007.01.012 · Cited by 195
Energy and exergy analyses of an experimental open-cycle desiccant cooling system
Kanoğlu, M., Çarpınlıoğlu, M. Ö., & Yıldırım, M. (2003) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2003.10.003 · Cited by 183
Experimental performance of a direct evaporative cooler operating during summer in a Brazilian city
Camargo, J. R., Ebinuma, C. D., & Silveira, J. L. (2005) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2004.12.011 · Cited by 171
On-site experimental testing of a novel dew point evaporative cooler
Bruno, F. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.09.013 · Cited by 170
Enteria, N. A., & Mizutani, K. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.01.013 · Cited by 167
Maclaine-cross, I. L., & Banks, P. J. (1981) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.3244505 · Cited by 162
Effectiveness of crossflow plate heat exchanger for indirect evaporative cooling
Stoichkov, N. Y., & Dimitrov, G. (1998) · International Journal of Refrigeration · doi:10.1016/s0140-7007(98)00004-8 · Cited by 160
Evaluation of the performance of local fibers in evaporative cooling
Al-Sulaiman, F. A. (2002) · Energy Conversion and Management · doi:10.1016/s0196-8904(01)00121-2 · Cited by 159
ENERGY STORAGE FOR DESICCANT COOLING SYSTEMS COMPONENT DEVELOPMENT
Keßling, W., Laevemann, E., & Kapfhammer, C. (1998) · Solar Energy · doi:10.1016/s0038-092x(98)00081-4 · Cited by 155
A simplified model for air dehumidification with liquid desiccant
Gandhidasan, P. (2003) · Solar Energy · doi:10.1016/j.solener.2003.10.001 · Cited by 149
Self-citationSolar-assisted air conditioning in buildings : a handbook for planners
Henning, H. (2007) · Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) · Cited by 147
Experimental study on a two-stage rotary desiccant cooling system
Ge, T., Li, Y., Wang, R. Z., & Dai, Y. (2008) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2008.07.001 · Cited by 140
Evaluation of solid-desiccant-based evaporative cooling cycles for typical hot and humid climates
Jain, S., Dhar, P. L., & Kaushik, S. C. (1995) · International Journal of Refrigeration · doi:10.1016/0140-7007(95)00016-5 · Cited by 125
Indirect evaporative cooling potential in air–water systems in temperate climates
Costelloe, B., & Finn, D. (2003) · Energy and Buildings · doi:10.1016/s0378-7788(02)00161-5 · Cited by 123
Optimisation of a desiccant cooling system design with indirect evaporative cooler
Goldsworthy, M., & White, S. D. (2010) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2010.07.005 · Cited by 113
An experimental study of a cross-flow type plate heat exchanger for dehumidification/cooling
Saman, W. Y., & Alizadeh, S. (2002) · Solar Energy · doi:10.1016/s0038-092x(01)00078-0 · Cited by 111
Performance of porous ceramic evaporators for building cooling application
Ibrahim, E., Shao, L., & Riffat, S. (2003) · Energy and Buildings · doi:10.1016/s0378-7788(03)00019-7 · Cited by 111
The use of solar desiccant cooling in the UK: a feasibility study
Halliday, S., Beggs, C. B., & Sleigh, A. (2002) · Applied Thermal Engineering · doi:10.1016/s1359-4311(02)00052-2 · Cited by 109
Application of desiccant wheel to control humidity in air-conditioning systems
Subramanyam, N., Maiya, M. P., & Murthy, S. S. (2004) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2004.04.008 · Cited by 107
Performance of a solar-regenerated liquid desiccant ventilation pre-conditioning system
Katejanekarn, T., & Kumar, S. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2007.11.005 · Cited by 102
Energy storage in open cycle liquid desiccant cooling systems
Keßling, W., Laevemann, E., & Peltzer, M. (1998) · International Journal of Refrigeration · doi:10.1016/s0140-7007(97)00045-5 · Cited by 100
Evaluation and optimization of solar desiccant wheel performance
Ahmed, M. H., Kattab, N. M., & Fouad, M. M. (2004) · Renewable Energy · doi:10.1016/j.renene.2004.04.010 · Cited by 99
Enteria, N. A., Yoshino, H., Satake, A., Mochida, A., Takaki, R., Yoshie, R., & Baba, S. (2009) · Applied Energy · doi:10.1016/j.apenergy.2009.08.026 · Cited by 85
Method of solar air conditioning
Dunkle, R. V. (1965) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 82
Modelling of indirect evaporative air coolers
Erens, P. J., & Dreyer, A. A. (1993) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(93)80062-y · Cited by 81
Historical review of liquid desiccant evaporation cooling technology
Mohammad, A. T., Mat, S., Sulaiman, M. Y., Sopian, K., & Al-Abidi, A. A. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2013.08.018 · Cited by 78
Performance improvement of a gas turbine cycle by using a desiccant-based evaporative cooling system
ZADPOOR, A. A., & GOLSHAN, A. (2005) · Energy · doi:10.1016/j.energy.2005.11.004 · Cited by 77
Saman, W. Y., & Alizadeh, S. (2001) · Solar Energy · doi:10.1016/s0038-092x(00)00148-1 · Cited by 75
Mathematical model of indirect evaporative cooler using porous ceramic and heat pipe
Riffat, S., & Zhu, J. T. (2003) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2003.09.011 · Cited by 70
Simulation model of an indirect evaporative cooler
Alonso, J. F. S. J., Martı́nez, F. J. R., Gómez, E. V., & Plasencia, M. A. Á.-G. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(98)00014-0 · Cited by 67
Enteria, N. A., Yoshino, H., Mochida, A., Takaki, R., Satake, A., Yoshie, R., Mitamura, T., & Baba, S. (2009) · Solar Energy · doi:10.1016/j.solener.2009.03.008 · Cited by 63
Al-Sulaiman, F. A., Gandhidasan, P., & Zubair, S. M. (2007) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2007.02.010 · Cited by 60
Self-citationA HEAT EXCHANGER FOR ENERGY SAVING IN AN AIR-CONDITIONING PLANT
Pescod, D. (1979) · Cited by 60
An evaporative and desiccant cooling system for air conditioning in humid climates
Camargo, J. R., Godoy, E., & Ebinuma, C. D. (2005) · Journal of the Brazilian Society of Mechanical Sciences and Engineering · doi:10.1590/s1678-58782005000300005 · Cited by 59
A parametric study of an indirect evaporative air cooler
Guo, X., & Zhao, T. S. (1998) · International Communications in Heat and Mass Transfer · doi:10.1016/s0735-1933(98)00008-6 · Cited by 58
Thermoeconomic analysis of an evaporative desiccant air conditioning system
Camargo, J. R., Ebinuma, C. D., & Silveira, J. L. (2003) · Applied Thermal Engineering · doi:10.1016/s1359-4311(03)00105-4 · Cited by 55
Thermal performance of a novel air conditioning system using a liquid desiccant
Oliveira, A. C., Afonso, C. F. A., Riffat, S., & Doherty, P. S. (2000) · Applied Thermal Engineering · doi:10.1016/s1359-4311(99)00087-3 · Cited by 55
Simulations of the performance of open cycle desiccant systems using solar energy
Nelson, J. S., Beckman, W. A., Mitchell, J. W., & Close, D. J. (1978) · Solar Energy · doi:10.1016/0038-092x(78)90003-8 · Cited by 54
Application of indirect evaporative cooling to variable domestic cooling load
Joudi, K. A., & Mehdi, S. M. (2000) · Energy Conversion and Management · doi:10.1016/s0196-8904(00)00004-2 · Cited by 52
A new ideal evaporative freezing cycle
Çerçı, Y. (2003) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(03)00072-3 · Cited by 51
An Overview of Open-Cycle Desiccant-Cooling Systems and Materials
Collier, R. K., Barlow, R. S., & Arnold, F. H. (1982) · Journal of Solar Energy Engineering · doi:10.1115/1.3266271 · Cited by 48
Henderson, H. I., & Rengarajan, K. (1996) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · Cited by 48
Beyond Kyoto: A tax-based system for the global reduction of greenhouse gas emissions
Kahn, J. R., & Franceschi, D. (2005) · Ecological Economics · doi:10.1016/j.ecolecon.2005.09.004 · Cited by 44
High Performance, Solid Desiccant, Open Cooling Cycles
Kang, T. S., & Maclaine-cross, I. L. (1989) · Journal of Solar Energy Engineering · doi:10.1115/1.3268304 · Cited by 41
Evaluation of liquid dessicant based evaporative cooling cycles for typical hot and humid climates
Jain, S., Dhar, P. L., & Kaushik, S. C. (1994) · Heat Recovery Systems and CHP · doi:10.1016/0890-4332(94)90032-9 · Cited by 38
Modeling of a solar-assisted desiccant air conditioner for a residential building
Smith, R., Hwang, C. C., & Dougall, R. S. (1994) · Energy · doi:10.1016/0360-5442(94)90007-8 · Cited by 36
Davanagere, B. S., Sherif, S. A., & Goswami, D. Y. (1999) · International Journal of Energy Research · Cited by 35
Novel design and modelling of an evaporative cooling system for buildings
Qiu, G., & Riffat, S. (2006) · International Journal of Energy Research · doi:10.1002/er.1199 · Cited by 34
Chen, P., Qin, G. H., Huang, Y. J., & Wu, H. (1989) · eScholarship (California Digital Library) · Cited by 21
Experimental Performance of a Direct Evaporative Cooler Operating in Kuala Lumpur
(2013) · International Journal of Thermal and Environmental Engineering · doi:10.5383/ijtee.06.01.003 · Cited by 20
Enhancement of the thermal performance of a wet cooling tower
El-Dessouky, H. (1996) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450740303 · Cited by 18
Building Technology: Mechanical and Electrical Systems
McGuinness, W. J., & Stein, B. P. (1977) · Medical Entomology and Zoology · Cited by 17
AN INVESTIGATION OF INDIRECT EVAPORATIVE COOLERS, IEC WITH RESPECT TO THERMAL COMFORT CRITERIA
Niasar, M. S., & Gilani, N. U. H. (2009) · Cited by 16
A novel summer air conditioning system
Al-Nimr, M. A., Nabah, B. A. A., & Naji, M. I. (2002) · Energy Conversion and Management · doi:10.1016/s0196-8904(01)00135-2 · Cited by 15
Measurement and Analysis of Heliostat Images
Kiera, M., & Schiel, W. (1989) · Journal of Solar Energy Engineering · doi:10.1115/1.3268283 · Cited by 13
Modeling of a regenerative indirect evaporative cooler for a desiccant cooling system
Bellemo, L., Elmegaard, B., Reinholdt, L., & Kærn, M. R. (2013) · Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU) · Cited by 11
Experimental and Theoretical Investigation of Integrated Engine Generator - Liquid Desiccant System
Nayak, S. M. (2005) · University Libraries (University of Maryland) · Cited by 10
The Use of Desiccant Cooling System with IEC and DEC in Hot-Humid Climates
Khoukhi, M., & Oman, M. (2013) · Cited by 10
Development and Testing of Regenerative Evaporative Cooler
Polytechnic, U. (2012) · Cited by 9
An Indirect Evaporative Cooler for Supplying Air near the Dew Point
Bruno, F., & Boulevard, M. L. (2010) · Adelaide Research & Scholarship (AR&S) (University of Adelaide) · Cited by 6
Mathematical Modeling of Solar Operated Liquid Desiccant, Evaporative Air Conditioning System
Radhwan, A. M., Elsayed, M. M., & Gari, H. A. (1999) · Journal of King Abdulaziz University-Engineering Sciences · doi:10.4197/eng.11-1.9 · Cited by 6
Efficient Technique of Air-Conditioning
Suryawanshi, S. D., Chordia, T. M., Nenwani, N., Bawaskar, H., & Yambal, S. (2011) · Cited by 5
Development of Desiccant and Evaporative Cooling Based 100% Outdoor System
Kim, M., & Jeong, J. (2013) · doi:10.1061/9780784412909.049 · Cited by 3
ANALYSIS OF DIFFERENT APPLICATIONS OF EVAPORATIVE COOLING SYSTEMS
Pimenta, J. M. D., Norte, A., & de Castro, W. P. (2003) · Cited by 3
Climatic change and rural–urban migration: The case of sub-Saharan Africa
Barrios, S., Bertinelli, L., & Strobl, E. (2006) · Journal of Urban Economics · doi:10.1016/j.jue.2006.04.005
Research works printed but not linked: 21
- Ameen A. The challenges of air-conditioning in tropical and humid tropical climates. In: Proceedings of the international conference on mechanical engineering (ICME2005), Dhaka, Bangladesh; 2005.
- Heidarinejad, 2009, Experimental investigation of two-stage indirect/direct evaporative cooling system in various climatic conditions, Build Environ, 44, 2073, 10.1016/j.buildenv.2009.02.017 · DOI
- Kulkarni, 2001, Performance evaluation of two stage indirect/direct evaporative cooler with alternative shapes and cooling media in direct stage, Int J Appl Eng, 1, 800
- Enteria, 2011, The role of the thermally activated desiccant cooling technologies in the issue of energy and environment, Renewable Sustainanle Energy Rev., 15, 2095, 10.1016/j.rser.2011.01.013 · DOI
- Dezfouli MMS, Mat S, Sopian K. Comparison simulation between ventilation and recirculation of solar desiccant cooling system by TRNSYS in hot and humid area. In: Proceedings of the seventh international conference on renewable energy sources, Kuala Lumpur, Malaysia, ISBN:978-1-61804-175-3; 2013.
- Haddad K, Ouazia B, Barhoun H. Simulation of a desiccant-evaporative cooling system for residential buildings. In: Third Canadian solar buildings conference, Fredericton, N.B.; 2008; p. 1–8.
- Parmar, 2010, Performance of a solid desiccant based evaporative cooling system in warm and humid climatic zone of India, Int J Eng Sci Technol, 2, 5504
- Wurtz E, Maalouf C, Mora L, Allard F. Parametric analysis of a solar desiccant cooling system using the SimSPARK Environment. In: Ninth international IBPSA conference Montréal, Canada; 2005. p. 15–18.
- Ouazia B, Barhoun H, Barhoun H, Haddad K, Armstrong MM, Marchand RG, Szadkowski F. Desiccant-evaporative cooling system for residential buildings. In: 12th Canadian conference on building science and technology Montréal, Québec; 2009.
- Saman, 2002, An experimental study of a cross-flow type plate heat exchanger for dehumidification/cooling, Sol Energy, 73, 59, 10.1016/S0038-092X(01)00078-0 · DOI
- Camargo JR, Ebinuma CD, Cardoso S. A mathematical model for direct and indirect evaporative cooling air conditioning systems. In: Proceedings of the ninth Brazilian congress of thermal engineering and sciences, ENCIT, UFPB, PB, paper CIT02-0855; 2002.
- Worek, 1991, Simulation of advanced gas-fired desiccant systems, ASHRAE Trans, 97, 609
- Eskra, 1980, Indirect–direct evaporative cooling systems, ASHRAE J, 22, 21
- Kulkarni, 2011, Performance evaluation of two stage indirect/direct evaporative cooler with alternative shapes and cooling media in direct stage, Int. J. Appl. Eng. Res., 1.4, 800
- Maclaine-Cross, 1981, A general theory of wet surface heat exchangers and its application to regenerative evaporative cooling, J Heat Transf -Trans Asme—J Heat Transf, 103, 579, 10.1115/1.3244505 · DOI
- Yellott, 1984, Indirect evaporative air coolers for hot, dry climates, ASHRAE Trans, 90, 139
- Eskra, 1980, Indirect/direct evaporative cooling systems, ASHRAE J., 22, 21
- Crum DR. Open cycle air conditioning systems. MS thesis, Wisconsin–Madison, USA; 1986.
- Bisoniya, 2011, Comparative thermal analysis of theoretical and experimental studies of modified indirect evaporative cooler having cross flow heat exchanger with one fluid mixed and the other unmixed, Int J Energy Environ, 2, 921
- Jose, 1998, Simulation model of an indirect evaporative cooler, Energy Build, 29, 23, 10.1016/S0378-7788(98)00014-0 · DOI
- SWEEP/WCEC. SWEEP/WCEC Workshop on modern evaporative cooling technologies, Boulder, CO; September 14, 2007.
Cited by
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180
Metadata
- Authors
- Mujahid Rafique, M., Gandhidasan, P., Rehman, S., & Al-Hadhrami, L. M.
- Affiliations
- King Fahd University of Petroleum and Minerals (SA)
- Corresponding author
- Gandhidasan, P.
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2015-05
- Volume
- 45
- Pages
- 145-159
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W2000826176
- Cited by
- 227
- References
- 77
- Citations by year
- 2026: 12 · 2025: 19 · 2024: 15 · 2023: 18 · 2022: 26 · 2021: 30 · 2020: 28 · 2019: 15 · 2018: 22 · 2017: 19 · 2016: 18 · 2015: 5
- FWCI
- 20.96
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Renewable and Sustainable Energy Reviews (publishedVersion)
- Funders
- National Plan for Science, Technology and Innovation
- King Abdulaziz City for Science and Technology
- King Fahd University of Petroleum and Minerals (10-ENE1372-04)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Solar-Powered Water Purification Methods
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Keywords
- evaporative coolers, latent load, air conditioning, solar cooling, thermal energy utilization, hot and humid climate, thermal comfort, energy consumption reduction, CO2 emission reduction, system configuration, operating modes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.