The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Natural and synthetic refrigerants, global warming: A review
Abstract
Abstract Halogenated hydrocarbons with high ozone depletion potential (ODP) were banned under Montreal Protocol (1987) due to their detrimental effects on ozone layer that shields the planet against ultraviolet radiations. The greenhouse gases (GHG) used in modern refrigeration, air conditioning, and heat pumping systems, are under Kyoto Protocol (1997)’s time-barred permission period. In order to reduce the depletion of ozone and reverse the climate change effects, the European Union legislation (2014) and Paris Accord (2016) are strongly emphasizing the phasing out of the use of harmful synthetic refrigerants. Choice of natural refrigerants makes no net addition of the greenhouse gases (GHG) in the environment. To retrofit and modify existing cooling and heating systems using natural refrigerants, extensive investigations are in progress worldwide. This work reviews timeworn, current and the next-generation refrigerants using Refrigerant Qualitative Parametric (RQP) quantification model to assist the refrigerant choice decision process. It is based on the ratio of arithmetic sums of actual parametric values of refrigerants normalized to equivalent ideal values. This model can help in choosing alternative refrigerants to replace CFCs by HCFCs or HFCs provisionally and finally replacing HCFCs or HFC to low GWP and ODP synthetic and natural refrigerants. A set of 16 refrigerants, both natural and synthetic, as an example, is computed for the standard Vapour Compression Cycle (VCC) based on the proposed model using REFPROP (NIST- 23 standard). The techno-economic parametric values of chosen refrigerants are taken from cited literature, ASHREA safety standards and international environmental legislations, laws and protocols. This paper reports the environment benign natural (CO2, NH3, HCs) and a few synthetic (R-152a, R-1234yf) refrigerants to be the optimal options.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stratospheric sink for chlorofluoromethanes: chlorine atom-catalysed destruction of ozone
Molina, M. J., & Rowland, F. S. (1974) · Nature · doi:10.1038/249810a0 · Cited by 4,332
XXXI.On the influence of carbonic acid in the air upon the temperature of the ground
Arrhenius, S. (1896) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786449608620846 · Cited by 1,695
Review of fossil fuels and future energy technologies
Abas, N., Kalair, A., & Khan, N. (2015) · Futures · doi:10.1016/j.futures.2015.03.003 · Cited by 1,348
Self-citationThe use of natural refrigerants: a complete solution to the CFC/HCFC predicament
Lorentzen, G. (1995) · International Journal of Refrigeration · doi:10.1016/0140-7007(94)00001-e · Cited by 405
A thermodynamic analysis of refrigerants: Possibilities and tradeoffs for Low-GWP refrigerants
McLinden, M. O., Kazakov, A. F., Steven Brown, J., & Domanski, P. A. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2013.09.032 · Cited by 388
Ejector enhanced vapor compression refrigeration and heat pump systems—A review
Sarkar, J. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.08.007 · Cited by 283
Environment friendly alternatives to halogenated refrigerants—A review
Mohanraj, M., Jayaraj, S., & Muraleedharan, C. (2009) · International Journal of Greenhouse Gas Control · doi:10.1016/j.ijggc.2008.07.003 · Cited by 281
Hydrocarbons as refrigerants in small heat pump and refrigeration systems – A review
Palm, B. E. (2007) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2007.11.016 · Cited by 270
Solar driven cooling systems: An updated review
Allouhi, A., Kousksou, T., Jamil, A., Bruel, P., Mourad, Y., & Zéraouli, Y. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.12.014 · Cited by 254
Harby, K. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.02.039 · Cited by 249
Review on solar-driven ejector refrigeration technologies
Abdulateef, J., Sopian, K., Alghoul, M. A., & Sulaiman, M. Y. (2008) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2008.08.012 · Cited by 211
Potential of nanorefrigerant and nanolubricant on energy saving in refrigeration system – A review
Azmi, W. H., Sharif, M. Z., Yusof, T. M., Mamat, R., & Redhwan, A. A. M. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.11.207 · Cited by 210
Large heat pumps in Swedish district heating systems
Averfalk, H., Ingvarsson, P., Persson, U., Gong, M., & Werner, S. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.135 · Cited by 207
Sarbu, I. (2014) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2014.04.023 · Cited by 202
Review of GHG emissions in Pakistan compared to SAARC countries
Abas, N., Kalair, A., Khan, N., & Kalair, A. R. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.04.022 · Cited by 189
Self-citationSolar community heating and cooling system with borehole thermal energy storage – Review of systems
Rad, F. M., & Fung, A. S. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.03.025 · Cited by 172
Pearson, A. (2007) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2007.11.011 · Cited by 154
Benhadid-Dib, S., & Benzaoui, A. (2012) · Energy Procedia · doi:10.1016/j.egypro.2012.05.096 · Cited by 133
Wallington, T. J., Andersen, M. P. S., & Nielsen, O. J. (2014) · Chemosphere · doi:10.1016/j.chemosphere.2014.06.092 · Cited by 125
Natural refrigerants for refrigeration and air-conditioning systems
Riffat, S., Afonso, C., Oliveira, A. C., et al. (1997) · Applied Thermal Engineering · doi:10.1016/1359-4311(96)00030-0 · Cited by 121
Retrofits and options for the alternatives to HCFC-22
Yang, Z., & Wu, X. (2013) · Energy · doi:10.1016/j.energy.2013.05.065 · Cited by 102
A thermodynamic analysis of refrigerants: Performance limits of the vapor compression cycle
Domanski, P. A., Brown, J. S., Heo, J., Wojtusiak, J., & McLinden, M. O. (2013) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2013.09.036 · Cited by 92
Experimental study on HFC-161 mixture as an alternative refrigerant to R502
Xuan, Y., & Chen, G. (2005) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2004.04.003 · Cited by 63
European Emissions of Halogenated Greenhouse Gases Inferred from Atmospheric Measurements
Keller, C. A., Hill, M., Vollmer, M. K., Henne, S., Brunner, D., Reimann, S., O’Doherty, S., Arduini, J., Maione, M., Ferenczi, Z., et al. (2011) · Environmental Science & Technology · doi:10.1021/es202453j · Cited by 60
Parametric Quantification of Low GWP Refrigerant for Thermosyphon Driven Solar Water Heating System
Abas, N., Nawaz, R., & Khan, N. (2015) · Procedia Computer Science · doi:10.1016/j.procs.2015.05.136 · Cited by 32
Self-citationGlobal warming from chlorofluorocarbons and their alternatives: Time scales of chemistry and climate
Ko, M. K. W., Sze, N. D., Molnar, G., et al. (1993) · Atmospheric Environment Part A General Topics · doi:10.1016/0960-1686(93)90215-k · Cited by 23
The evaluation of time variation global warming effects, TWPA and CWP, for CFC alternatives
Sekiya, A. (2007) · Journal of Fluorine Chemistry · doi:10.1016/j.jfluchem.2007.04.024 · Cited by 5
Cited by
Gas hydrates in sustainable chemistry
Hassanpouryouzband, A., Joonaki, E., Vasheghani Farahani, M., Takeya, S., Ruppel, C., Yang, J., English, N. J., Schicks, J. M., Edlmann, K., Mehrabian, H., et al. (2020) · Chemical Society Reviews · doi:10.1039/c8cs00989a · Cited by 809
Overview of low GWP mixtures for the replacement of HFC refrigerants: R134a, R404A and R410A
Heredia-Aricapa, Y., Belman-Flores, J. M., Mota-Babiloni, A., Serrano-Arellano, J., & García-Pabón, J. J. (2020) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2019.11.012 · Cited by 307
Limitations, challenges, and solution approaches in grid‐connected renewable energy systems
Basit, M. A., Dilshad, S., Badar, R., & Sami ur Rehman, S. M. (2020) · International Journal of Energy Research · doi:10.1002/er.5033 · Cited by 305
Mikulčić, H., Ridjan Skov, I., Dominković, D. F., Wan Alwi, S. R., Manan, Z. A., Tan, R., Duić, N., Hidayah Mohamad, S. N., & Wang, X. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.109338 · Cited by 299
Characterization of Hybrid FRP Composite Produced from Recycled PET and CFRP
Almahri, G., Madi, K., Alkaabi, F., Badran, Y., Shehadeh, K., ElHassan, A., Ahmed, W., & Alzahmi, S. (2023) · Polymers · doi:10.3390/polym15132946 · Cited by 18
Metadata
- Authors
- Abas, N., Kalair, A. R., Khan, N., Haider, A., Saleem, Z., & Saleem, M. S.
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 90
- Pages
- 557-569
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W2799850516
- Cited by
- 486
- References
- 27
- FWCI
- 23.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.