Assessment techniques of the impact of grid-tied rooftop photovoltaic generation on the power quality of low voltage distribution network—A review
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The deterministic method considers worst-case scenarios to determine HC due to the extreme impact of uncertain parameters.
“The deterministic method also considers the worst-case scenarios to determine the HC due to the extreme impact of uncertain parameters [60][61][62].”
From Methods and Tools for PV and EV Hosting Capacity Determination in Low Voltage Distribution Networks—A Review (2023) · cites this paper as [62]
The citation lists haven’t been fetched yet
References 117 · Cited by 193
- Authors
- Kharrazi, A., Sreeram, V., & Mishra, Y.
- Affiliations
- The University of Western Australia (AU)
- Queensland University of Technology (AU)
- Corresponding author
- Kharrazi, A.
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 120
- Pages
- 109643
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W2994925146
- Cited by
- 193
- References
- 117
- Citations by year
- 2026: 12 · 2025: 26 · 2024: 36 · 2023: 49 · 2022: 30 · 2021: 29 · 2020: 11
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Renewable and Sustainable Energy Reviews (publishedVersion)
- UWA Profiles and Research Repository (UWA) (submittedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Safety, Risk, Reliability and Quality › Power System Reliability and Maintenance
- Keywords
- power quality, low-voltage distribution networks, voltage unbalance, current imbalance, harmonic distortion, voltage rise, uncertainty modeling, stochastic assessment, power quality indices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review