The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
A state-of-the-art review on the vibration mitigation of wind turbines
Abstract
Abstract Wind energy as one of the renewable energies is serving as an indispensable role in generating new electric power. The worldwide installation of wind farms has considerably increased recently. To extract more wind resources, multi-megawatt wind turbines are usually designed and constructed with large rotors and slender tower. These flexible structures are susceptible to external dynamic excitations such as wind, wave and seismic loads. The excessive vibrations can compromise the wind energy conversion, lead to the structural fatigue damage and even result in the catastrophic failure of wind turbines in harsh environmental conditions. Various control devices have been proposed and used to mitigate the unwanted vibrations of wind turbines to enhance their safety and serviceability. This paper aims to provide a state-of-the-art review of the current vibration control techniques and their applications to wind turbines. Firstly, the widely used control strategies in engineering structures are briefly introduced. Their applications to suppress the adverse vibrations of the structural components of wind turbines, mainly the tower and blades, are then reviewed and discussed in detail. It can be concluded that the vibration mitigation of wind turbines is very challenging due to the fact that the dynamic behaviours of wind turbines are very complicated, which are associated with the aerodynamics, rotation of the blades, interaction between the tower and rotating blades, and soil-structure interaction, etc. Moreover, it is a challenge to straightforwardly use many of the conventional control devices because of the limited spaces in the tower and blades.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuned liquid column dampers in offshore wind turbines for structural control
Colwell, S., & Basu, B. (2009) · Engineering Structures · doi:10.1016/j.engstruct.2008.09.001 · Cited by 406 · cited 5×
“In which, Colwell and Basu [45] firstly proposed H. Zuo et al. Renewable and Sustainable Energy Reviews 121 (2020) 109710 using a single TLCD to reduce the vibration of the tower under different wind speeds without considering the dynamic behaviours of the blades.”
BackgroundInfluentialPassive structural control of offshore wind turbines
Lackner, M. A., & Rotea, M. A. (2011) · Wind Energy · doi:10.1002/we.426 · Cited by 378 · cited 3×
“The effectiveness of this control method were examined for the fixed-bottom monopile wind turbine, and the wind turbines with floating substructures such as barge, spar-buoy and tension-leg [22,23].”
MethodMurtagh, P. J., Ghosh, A., Basu, B., & Broderick, B. M. (2008) · Wind Energy · doi:10.1002/we.249 · Cited by 278 · cited 1×
“[21] installed a TMD in the nacelle to mitigate the wind-induced vibrations of the tower.”
BackgroundSeismic response mitigation of a wind turbine tower using a tuned parallel inerter mass system
Zhang, R., Zhao, Z., & Dai, K. (2019) · Engineering Structures · doi:10.1016/j.engstruct.2018.11.020 · Cited by 273
Hu, Y., Wang, J., Chen, M. Z. Q., Li, Z., & Sun, Y. (2018) · Engineering Structures · doi:10.1016/j.engstruct.2018.09.063 · Cited by 200 · cited 2×
“[35], three different configurations as shown in Fig.”
MethodZhang, Z., Staino, A., Basu, B., & Nielsen, S. R. K. (2016) · Engineering Structures · doi:10.1016/j.engstruct.2016.07.008 · Cited by 150 · cited 3×
“17, and the effectiveness of using these TLDs for wind turbine tower vibration mitigation has been experimentally [58,61,62] or numerically [59,60] investigated.”
BackgroundActive tuned mass dampers for control of in-plane vibrations of wind turbine blades
Fitzgerald, B., Basu, B., & Nielsen, S. R. K. (2013) · Structural Control and Health Monitoring · doi:10.1002/stc.1524 · Cited by 142 · cited 14×
“One was a control force of the ATMD acted on the blade to reduce its in-plane vibration.”
MethodInfluentialVibration mitigation in offshore wind turbines via tuned mass damper
Ghassempour, M., Failla, G., & Arena, F. (2019) · Engineering Structures · doi:10.1016/j.engstruct.2018.12.092 · Cited by 124 · cited 1×
“Moreover, the vibration characteristics of the wind turbine in the operating condition can be changed by the blades [89,90] since the centrifugal stiffness generated by the rotating blades can increase the stiffness and frequencies of the blades, which in turn indirectly affect the dynamic responses of the wind turbin…”
Background
Cited by
Inerter-based structural vibration control: A state-of-the-art review
Ma, R., Bi, K., & Hao, H. (2021) · Engineering Structures · doi:10.1016/j.engstruct.2021.112655 · Cited by 445
Self-citation
Metadata
- Authors
- Zuo, H., Bi, K., & Hao, H.
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 121
- Pages
- 109710
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W2998860679
- Cited by
- 245
- References
- 8
- FWCI
- 16.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.