Waste heat recoveries in data centers: A review
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Data centers (DCs) uninterruptedly run 24/24 h, 365 days per year with much huge operating scale, and have the characteristics of high operation safety requirement, high heat flux density, high energy consumption and high carbon emission. They are influential energy consumers and carbon emitters in building or even global energy sectors (around 3% of global energy consumption), who are also significant waste heat producer (e.g., waste heat from year-round uninterrupted operation of IT equipment and cooling system). Huge energy consumption has increased the burden on the global energy industry, while carbon and direct waste heat emissions have also caused great damages to the outdoor environment. Thus, it is critical to improve the energy efficiency in DCs and to realize the energy conservations and environmental deterioration alleviation. Waste heat recovery technology is considered as a promising approach to improve energy efficiency, achieve energy and energy cost savings, and mitigate environmental impacts (caused by both carbon emission and waste heat discharge) at the same time. This article conducts a comprehensive review on recovering waste heat from all kind of sources (e.g., exhaust air, circulating water, and coolants) in DCs for various energy uses (e.g., heating supply, district heating supplement, cooling and electricity productions, and industrial/agricultural production process) and different application scenarios (e.g., office buildings, comprehensive energy community and residential buildings), while the future research and development proposals for DC waste heat recoveries are given through technical, energy, environmental and economic analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On Global Electricity Usage of Communication Technology: Trends to 2030
Andrae, A., & Edler, T. (2015) · Challenges · doi:10.3390/challe6010117 · Cited by 1,334
A review of thermodynamic cycles and working fluids for the conversion of low-grade heat
Chen, H., Goswami, D. Y., & Stefanakos, E. K. (2010) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2010.07.006 · Cited by 1,321
Assessing ICT global emissions footprint: Trends to 2040 & recommendations
Belkhir, L., & Elmeligi, A. (2018) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2017.12.239 · Cited by 970
A review of absorption refrigeration technologies
Srikhirin, P., Aphornratana, S., & Chungpaibulpatana, S. (2001) · Renewable and Sustainable Energy Reviews · doi:10.1016/s1364-0321(01)00003-x · Cited by 873
Ebrahimi, K., Jones, G. F., & Fleischer, A. S. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.12.007 · Cited by 779
Huang, P., Copertaro, B., Zhang, X., Shen, J., Löfgren, I., Rönnelid, M., Fahlen, J., Andersson, D., & Svanfeldt, M. (2020) · Applied Energy · doi:10.1016/j.apenergy.2019.114109 · Cited by 414
Yari, M., Mehr, A. S., Zare, V., Mahmoudi, S. M. S., & Rosen, M. A. (2015) · Energy · doi:10.1016/j.energy.2015.02.080 · Cited by 312
Aquasar: A hot water cooled data center with direct energy reuse
Zimmermann, S., Meijer, I., Tiwari, M. K., Paredes, S., Michel, B., & Poulikakos, D. (2012) · Energy · doi:10.1016/j.energy.2012.04.037 · Cited by 276
Wahlroos, M., Pärssinen, M., Manner, J., & Syri, S. (2017) · Energy · doi:10.1016/j.energy.2017.08.078 · Cited by 249
Future views on waste heat utilization – Case of data centers in Northern Europe
Wahlroos, M., Pärssinen, M., Rinne, S., Syri, S., & Manner, J. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.10.058 · Cited by 233
Ebrahimi, K., Jones, G. F., & Fleischer, A. S. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.10.067 · Cited by 226
Phase change cooling in data centers: A review
Yuan, X., Zhou, X., Pan, Y., Kosonen, R., Cai, H., Gao, Y., & Wang, Y. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.110764 · Cited by 169
Self-citationUsing data centres for combined heating and cooling: An investigation for London
Davies, G. F., Maidment, G. G., & Tozer, R. M. (2016) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2015.09.111 · Cited by 166
Deymi‐Dashtebayaz, M., & Namanlo, S. V. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.02.061 · Cited by 156
Analysis of a district heating system using waste heat in a distributed cooling data center
He, Z., Ding, T., Liu, Y., & Li, Z. (2018) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2018.06.036 · Cited by 145
Thermodynamic feasibility of harvesting data center waste heat to drive an absorption chiller
Haywood, A. M., Sherbeck, J., Phelan, P. E., Varsamopoulos, G., & Gupta, S. K. S. (2012) · Energy Conversion and Management · doi:10.1016/j.enconman.2011.12.017 · Cited by 129
Bellos, E., Tzivanidis, C., & Antonopoulos, K. A. (2016) · Energy Conversion and Management · doi:10.1016/j.enconman.2016.06.068 · Cited by 122
Li, H., Hou, J., Hong, T., Ding, Y., & Nord, N. (2020) · Energy · doi:10.1016/j.energy.2020.119582 · Cited by 119
Oró, E., Taddeo, P., & Salom, J. (2018) · Sustainable Cities and Society · doi:10.1016/j.scs.2018.12.012 · Cited by 106
Lu, Z. S., Wang, R. Z., Xia, Z. Z., et al. (2012) · Renewable Energy · doi:10.1016/j.renene.2012.07.001 · Cited by 103
Oró, E., Allepuz, R., Martorell, I., & Salom, J. (2017) · Sustainable Cities and Society · doi:10.1016/j.scs.2017.10.012 · Cited by 88
Waste heat from data centers: An investment analysis
Pärssinen, M., Wahlroos, M., Manner, J., & Syri, S. M. (2018) · Sustainable Cities and Society · doi:10.1016/j.scs.2018.10.023 · Cited by 85
Waste heat recovery in a data center with an adsorption chiller: Technical and economic analysis
Gupta, R., & Puri, I. K. (2021) · Energy Conversion and Management · doi:10.1016/j.enconman.2021.114576 · Cited by 80
Chen, H., Peng, Y.-H., & Wang, Y. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2018.12.117 · Cited by 78
Ebrahimi, K., Jones, G. F., & Fleischer, A. S. (2017) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2017.07.001 · Cited by 70
A novel variable effect LiBr-water absorption refrigeration cycle
Xu, Z., Wang, R. Z., & Xia, Z. Z. (2013) · Energy · doi:10.1016/j.energy.2013.08.033 · Cited by 70
Chen, X., Pan, M., Li, X., & Zhang, K. (2022) · Energy Conversion and Management · doi:10.1016/j.enconman.2022.115820 · Cited by 65
Ljungdahl, V. B., Jradi, M., & Veje, C. T. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2021.117671 · Cited by 65
Marshall, Z., & Duquette, J. (2021) · Energy · doi:10.1016/j.energy.2021.122528 · Cited by 65
Murphy, A. R., & Fung, A. S. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.01.012 · Cited by 55
Sustainability Analysis of Green Data Centers With CCHP and Waste Heat Reuse Systems
Wan, J., Zhou, J., & Gui, X. (2020) · IEEE Transactions on Sustainable Computing · doi:10.1109/tsusc.2020.2979473 · Cited by 52
Huang, Q., Shao, S., Zhang, H., & Tian, C. (2019) · Energy · doi:10.1016/j.energy.2019.116200 · Cited by 51
Yuan, X., Heikari, L., Hirvonen, J., Liang, Y., Virtanen, M., Kosonen, R., & Pan, Y. (2022) · Energy Conversion and Management · doi:10.1016/j.enconman.2022.115918 · Cited by 41
Self-citationAmiri, L., Madadian, E., Bahrani, N., & Ghoreishi‐Madiseh, S. A. (2021) · Energies · doi:10.3390/en14092433 · Cited by 39
Dvořák, V., Zavřel, V., Torrens, J. I., & Hensen, J. J. (2020) · Building Simulation · doi:10.1007/s12273-020-0629-y · Cited by 38
Kanbur, B. B., Wu, C., & Duan, F. (2020) · International Journal of Energy Research · doi:10.1002/er.5677 · Cited by 32
Kanbur, B. B., Wu, C., & Duan, F. (2020) · International Journal of Energy Research · doi:10.1002/er.5256 · Cited by 27
Comprehensive fuzzy logic coefficient of performance of absorption cooling system
Imamović, B., Halilčević, S. S., & Georgilakis, P. S. (2021) · Expert Systems with Applications · doi:10.1016/j.eswa.2021.116185 · Cited by 25
Sondur, S., Gross, K. C., & Li, M. (2018) · International Green and Sustainable Computing Conference · doi:10.1109/igcc.2018.8752108 · Cited by 13
Yuan, X., Zhou, X., Liang, Y., Pan, Y., Kosonen, R., & Lin, Z. (2022) · Buildings · doi:10.3390/buildings12071015 · Cited by 13
Self-citationHeating Homes with Servers: Workload Scheduling for Heat Reuse in Distributed Data Centers
Antal, M., Cristea, A.-A., Pădurean, V.-A., Cioara, T., Anghel, I. M., Antal, C., Salomie, I., & Sainthérant, N. (2021) · Sensors · doi:10.3390/s21082879 · Cited by 9
Energy management for data centre microgrids considering co‐optimisation of workloads and waste heat
Tian, M., Zhang, H., & Wu, H. (2021) · IET Energy Systems Integration · doi:10.1049/esi2.12044 · Cited by 8
Metadata
- Authors
- Yuan, X., Liang, Y., Hu, X., Xu, Y., Chen, Y., & Kosonen, R.
- Venue
- Renewable and Sustainable Energy Reviews
- Publisher
- Elsevier BV
- Published
- 2023-12
- Volume
- 188
- Pages
- 113777
- ISSN
- 1364-0321 (ISSN-L)
- OpenAlex
- W4387252196
- Cited by
- 177
- References
- 42
- FWCI
- 17.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.