Simultaneous detection of atmospheric CO and CH4 based on TDLAS using a single 2.3 μm DFB laser
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A laser-based spectrometer with a physical size of 60× 30 ×25 cm3 has been developed to continuously monitor CO and CH4 in atmosphere based on tunable diode laser absorption spectroscopy (TDLAS). Two neighboring lines of CO and CH4 around 2.3 μm were selected as candidates for simultaneous measurement by a single diode distributed feedback (DFB) laser. A special Herriott-type multipass absorption cell, with a 72 m optical path length, was designed and used to enhance the absorption signals of sample gases. Normalized wavelength modulation spectroscopy was applied to improve the sensitivity and robustness of the spectrometer and it was implemented on a home-made electronic system based on field programmable gate array (FPGA). Meanwhile, the electronic system controlled the temperature and current of DFB laser with the precision of 0.01 °C and 40 ppm. The 2nd-harmonic signals normalized by the corresponding 1st-harmonic signals for both CO and CH4 are of high linear response to their concentrations in the range of 0.046-4.6 ppm and 0.487-48.7 ppm, respectively. According to the Allan variance, respective minimum detection limits for CO and CH4 are 0.73 ppb and 36 ppb at 122 s and 137 s. As an application example, the spectrometer has been validated through real-time and in-situ measurement of atmospheric CO and CH4 for 48 h.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The HITRAN2016 molecular spectroscopic database
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., et al. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.06.038 · Cited by 7,721
Cited by
Liu, N., Xu, L., Zhou, S., Zhang, L., & Li, J. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01910 · Cited by 168
Metadata
- Authors
- Shao, L., Fang, B., Zheng, F., Qiu, X., He, Q., Wei, J., Li, C., & Zhao, W.
- Venue
- Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 222
- Pages
- 117118
- ISSN
- 1386-1425 (ISSN-L)
- OpenAlex
- W2950414856
- Cited by
- 165
- References
- 1
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous detection of atmospheric CO and CH4 based on TDLAS using a single 2.3 μm DFB laser. https://app.cochat.ai/papers/10.1016/j.saa.2019.05.023
- The paper
- Shao, L., Fang, B., Zheng, F., Qiu, X., He, Q., Wei, J., Li, C., & Zhao, W. (2019). Simultaneous detection of atmospheric CO and CH4 based on TDLAS using a single 2.3 μm DFB laser. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2019.05.023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.