Smart structures: Part II — Hybrid control systems and control strategies
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In a companion paper, the writers reviewed significant work done on active and semi-active vibration control of structures performed in the past decade or so. In this paper, journal articles on the hybrid vibration control of structures and control strategies, published during the same period, are reviewed. They include hybrid mass dampers, semi-active base isolators, actuators with passive dampers, and semi-active Tuned Liquid Column Dampers (TLCD) with passive dampers. A key element in successful implementation of smart structure technology is an effective control algorithm to compute the magnitudes of internal forces to be applied to the structure. Various improved or new control strategies developed for civil structures are reviewed in this paper. They include modified LQR and LQG, neural network-based, fuzzy logic, sliding mode and wavelet-based controllers. Studies on optimum placement of control devices are also summarized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smart structures: Part I—Active and semi-active control
Fisco, N. R., & Adeli, H. (2011) · Scientia Iranica · doi:10.1016/j.scient.2011.05.034 · Cited by 270
Self-citation
Cited by
Gutierrez Soto, M., & Adeli, H. (2013) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-013-9091-7 · Cited by 346
Self-citation3D displacement measurement model for health monitoring of structures using a motion capture system
Park, S. W., Park, H. S., Kim, J. H., & Adeli, H. (2015) · Measurement · doi:10.1016/j.measurement.2014.09.063 · Cited by 300
Self-citationSmart structures: Part I—Active and semi-active control
Fisco, N. R., & Adeli, H. (2011) · Scientia Iranica · doi:10.1016/j.scient.2011.05.034 · Cited by 270
Self-citationSemi-active vibration absorber based on real-time controlled MR damper
Weber, F. (2014) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2014.01.017 · Cited by 180
Invited Review: Recent developments in vibration control of building and bridge structures
Ghaedi, K., Ibrahim, Z., Adeli, H., & Javanmardi, A. (2017) · Journal of Vibroengineering · doi:10.21595/jve.2017.18900 · Cited by 146
“Fisco and Adeli [6] brought forward a state-of-the-art review of active control of structures including active tuned mass dampers (ATMD), active tendon systems, active magnetorheological (MR) dampers, distributed actuators, piezoelectric dampers (PDs), semi-active stiffness dampers (SASD) and semi-active tuned liquid…”
InfluentialSelf-citation
Metadata
- Authors
- Fisco, N. R., & Adeli, H.
- Venue
- Scientia Iranica
- Publisher
- Elsevier BV
- Published
- 2011-06
- Volume
- 18
- Issue
- 3
- Pages
- 285-295
- ISSN
- 1026-3098 (ISSN-L)
- OpenAlex
- W1997829451
- Cited by
- 177
- References
- 1
- FWCI
- 26.81
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Smart structures: Part II — Hybrid control systems and control strategies. https://app.cochat.ai/papers/10.1016/j.scient.2011.05.035
- The paper
- Fisco, N. R., & Adeli, H. (2011). Smart structures: Part II — Hybrid control systems and control strategies. Scientia Iranica. https://doi.org/10.1016/j.scient.2011.05.035
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.