Cited by 0Microgrid Control and OptimizationOptimal Power Flow DistributionReal-time simulation and control systems

Validation of a data-driven multi-ancillary services framework for photovoltaic/Storage units via power hardware-in-the-loop testing

Open access
Pippi, Kalliopi D., Kryonidis, Georgios C., Papadopoulos, Theofilos A., Feng, Zhiwang, Syed, Mazheruddin H., Burt, Graeme M.·2026·Sustainable Energy, Grids and Networks

Abstract

This paper presents the experimental validation of a unified multi-ancillary services (AS) architecture for distributed photovoltaic–battery energy storage (PV-DBESS) systems using power hardware-in-the-loop (PHiL) testing. The focus is on voltage regulation (VR) and voltage unbalance mitigation (VUM), with full decoupling between the two control schemes to ensure interference-free operation. Experiments are conducted on a small-scale distribution network using a hybrid PHiL setup that combines real-time simulation with physical hardware, bridging the simulation-to-practice gap. A detailed three-phase four-leg converter model with embedded VR and VUM algorithms is implemented in RSCAD, and simplified controllable current source models are also evaluated to balance computational efficiency with accuracy. The results demonstrate that the proposed control strategies effectively mitigate overvoltage and unbalance events across varying operating conditions and network characteristics. The VUM scheme leverages reactive power through virtual damping susceptances, while the VR scheme coordinates active and reactive power to regulate the positive-sequence voltage. Interoperability with conventional constant-power converters is also verified. The study confirms that the proposed AS architecture provides a robust and practical solution for enhancing reliability and hosting capacity in active distribution networks, while indicating its potential suitability for future large-scale real-time studies and integration with advanced grid operation systems, particularly through the use of simplified converter models.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.segan.2026.102133

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 20

Authors
Pippi, K. D., Kryonidis, G. C., Papadopoulos, T. A., Feng, Z., Syed, M. H., & Burt, G. M.
Affiliations
  • Aristotle University of Thessaloniki (GR)
  • University of Strathclyde (GB)
Corresponding author
  • Papadopoulos, Theofilos A.
  • Feng, Zhiwang
Venue
Sustainable Energy, Grids and Networks
Publisher
Elsevier BV
Published
2026-03
Volume
45
Pages
102133
ISSN
2352-4677 (ISSN-L)
OpenAlex
W7126090917
Cited by
0
References
20
FWCI
0.00
Type
journal article
Language
en
Open access
Locations
  • Sustainable Energy Grids and Networks (publishedVersion, cc-by)
  • Strathprints: The University of Strathclyde institutional repository (University of Strathclyde) (submittedVersion)
Funders
Horizon Europe
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
  • Physical Sciences › Engineering › Control and Systems Engineering › Real-time simulation and control systems
Keywords
ancillary services, photovoltaic-battery energy storage system, distributed energy resources, voltage regulation, voltage unbalance mitigation, power hardware-in-the-loop, four-leg converter, reactive power control, active distribution networks, hosting capacity, overvoltage suppression

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review