CoChat

Diagnostic accuracy of a structured interview for nocturnal frontal lobe epilepsy (SINFLE): A proposal for developing diagnostic criteria

Open access
Bisulli, Francesca, Vignatelli, Luca, Naldi, Ilaria, Pittau, Francesca, Provini, Federica, Plazzi, Giuseppe, Stipa, Carlotta, Leta, Chiara, Montagna, Pasquale, Tinuper, Paolo · 2012 · Sleep Medicine
Cited by 46

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

OBJECTIVES To measure the accuracy of anamnestic features collected during clinical history for the diagnosis of nocturnal frontal lobe epilepsy (NFLE). METHODS A case-control diagnostic study. Participants included a case group of people with ascertained target disease (NFLE group) and a control group of people with sleep disorders potentially confounding for NFLS (NOT-NFLE group), defined by means of a consensus procedure among experts (panel diagnosis as reference standard). Two major clinical patterns defining the semeiology of the epileptic event (i.e. dystonic, DP, and/or hyperkinetic pattern, HP), and 13 additional minor features were identified, formulated as questions, and telephonically administered to NFLE and NOT-NFLE groups by a trained doctor blinded to the final diagnosis. The diagnostic accuracy of each characteristic was tested against the reference standard. RESULTS Out of 262 selected subjects, 101 were recruited; 42 were NFLE and 59 NOT-NFLE. A positive history of DP or HP had a sensitivity of 59.5% and a specificity of 91.5%, irrespective of the other minor anamnestic features. The anamnestic model improved, with a sensitivity of 59.5% and specificity of 96.6%, if at least one of the following four minor anamnestic features was added: (a) duration less than two minutes, (b) unstructured vocalization during the episode, (c) experience of an aura preceding the motor attack, and (d) a history of tonic-clonic seizures during sleep. CONCLUSIONS The present study disclosed two major anamnestic patterns and four minor features that we called SINFLE, with unsatisfactory sensitivity but high specificity. These patterns could be the basis for developing future NFLE diagnostic criteria and to quantify the diagnostic accuracy of elements usually collected in the clinical history.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.sleep.2011.09.003

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 46

Metadata

Authors
Bisulli, F., Vignatelli, L., Naldi, I., Pittau, F., Provini, F., Plazzi, G., Stipa, C., Leta, C., Montagna, P., & Tinuper, P.
Venue
Sleep Medicine
Publisher
Elsevier BV
Published
2012-01
Volume
13
Issue
1
Pages
81-87
ISSN
1389-9457 (ISSN-L)
OpenAlex
W2113401706
Cited by
46
References
7
FWCI
1.77
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic accuracy of a structured interview for nocturnal frontal lobe epilepsy (SINFLE): A proposal for developing diagnostic criteria. https://app.cochat.ai/papers/10.1016/j.sleep.2011.09.003
The paper
Bisulli, F., Vignatelli, L., Naldi, I., Pittau, F., Provini, F., Plazzi, G., Stipa, C., Leta, C., Montagna, P., & Tinuper, P. (2012). Diagnostic accuracy of a structured interview for nocturnal frontal lobe epilepsy (SINFLE): A proposal for developing diagnostic criteria. Sleep Medicine. https://doi.org/10.1016/j.sleep.2011.09.003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.