CoChat

A novel, co-located EMG-FMG-sensing wearable armband for hand gesture recognition

Jiang, Shuo, Gao, Qinghua, Liu, Huaiyang, Shull, Peter B. · 2020 · Sensors and Actuators A: Physical
Cited by 169

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Abstract Gestures play an important role in human-computer interaction, providing a potentially intuitive way to bridge the gap between human intention and the control of smart devices. Electromyography (EMG) and force myography (FMG) are two commonly-adopted wearable sensing modalities for gesture recognition. Previous research approaches utilize only a single modality (EMG or FMG) at any given muscle location, thus limiting the amount of potentially-useful biological hand gesture information. We thus propose a novel co-located approach (EMG and FMG) for capturing both sensing modalities, simultaneously, at the same location. We developed a novel hand gesture recognition armband consisting of 8 co-located EMG-FMG sensing units (size and weight of each EMG-FMG sensing unit was 11 × 13 × 6 mm and 0.90 g, respectively). Five subjects performed a hand gesture recognition experiment for American Sign Language digits 0–9 while wearing the co-located EMG-FMG armband on the forearm. Hand gesture classification accuracy was 81.5 % for EMG only, 80.6 % FMG only, and 91.6 % for co-located EMG-FMG. These results suggest that co-located EMG-FMG may lead to higher hand gesture classification accuracy than sensing approaches using either EMG or FMG in isolation. To the best of our knowledge, this is the first prototype that measures EMG and FMG simultaneously at the same muscle location for hand gesture recognition. Implications of this work could positively impact a variety of muscle activity monitoring research applications including biomechanics modeling, prosthesis control, and gesture recognition.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.sna.2019.111738

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 169

Metadata

Authors
Jiang, S., Gao, Q., Liu, H., & Shull, P. B.
Venue
Sensors and Actuators A: Physical
Publisher
Elsevier BV
Published
2020-01
Volume
301
Pages
111738
ISSN
0924-4247 (ISSN-L)
OpenAlex
W2987322373
Cited by
169
References
3
FWCI
5.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A novel, co-located EMG-FMG-sensing wearable armband for hand gesture recognition. https://app.cochat.ai/papers/10.1016/j.sna.2019.111738
The paper
Jiang, S., Gao, Q., Liu, H., & Shull, P. B. (2020). A novel, co-located EMG-FMG-sensing wearable armband for hand gesture recognition. Sensors and Actuators A: Physical. https://doi.org/10.1016/j.sna.2019.111738

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.