The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Highly selective Hg2+ colorimetric sensor using green synthesized and unmodified silver nanoparticles
Open accessAbstract
The reaction between biologically green synthesized silver nanoparticles (Ag NPs) and mercury (II) ions was introduced as a new and high potential colorimetric sensor for the selective recognition and monitoring of mercuric ions in aqueous samples. The green synthesized silver nanoparticles were characterized with surface plasmon resonance (SPR) ultraviolet spectroscopy (UV–vis), SEM and X-ray diffraction analysis (XRD) techniques. The fresh biologically synthesized silver nanoparticles are yellowish-brown in color due to the intense SPR absorption band. In the presence of Hg 2+ , the yellow Ag NPs solution was turned to colorless, accompanying the broadening and blue shifting of SPR band. The sensitivity and selectivity of green prepared Ag NPs toward other representative transition-metal ions, alkali metal ions and alkaline earth metal ions were studied. Also the effect of the concentration of Hg 2+ to the Ag NPs was considered and the LOD for mercury (II) ion was 2.2 × 10 −6 mol L −1 . The proposed method has been successfully used for the determination of mercury (II) ions in various water samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1999) · Choice Reviews Online · doi:10.5860/choice.37-0940 · Cited by 14,314
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Standard Potentials in Aqueous Solution
Bard, A. J., Parsons, R., & Jordan, J. (2017) · Routledge eBooks · doi:10.1201/9780203738764 · Cited by 2,311
The toxicology of mercury—current exposures and clinical manifestations
Clarkson, T. W., Magos, L., & Myers, G. J. (2003) · New England Journal of Medicine · doi:10.1056/nejmra022471 · Cited by 1,766
Standard Potentials in Aqueous Solution.
Trasatti, S. (1987) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(87)80040-5 · Cited by 1,633
A molecular ruler based on plasmon coupling of single gold and silver nanoparticles
Sönnichsen, C., Reinhard, B. M., Liphardt, J., & Alivisatos, A. P. (2005) · Nature Biotechnology · doi:10.1038/nbt1100 · Cited by 1,523
Lee, J., Han, M. S., & Mirkin, C. A. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200700269 · Cited by 1,308
Review: Environmental exposure to mercury and its toxicopathologic implications for public health
Tchounwou, P. B., Ayensu, W. K., Ninashvili, N., & Sutton, D. (2003) · Environmental Toxicology · doi:10.1002/tox.10116 · Cited by 1,298
Yang, Y.-K., Yook, K.-J., & Tae, J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054855t · Cited by 1,044
Liu, J., & Lu, Y. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200702006 · Cited by 593
Cited by
Rana, A., Yadav, K., & Jagadevan, S. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2020.122880 · Cited by 673
Silver-Based Plasmonic Nanoparticles for and Their Use in Biosensing
Loiseau, A., Asila, V., Boitel-Aullen, G., Lam, M., Salmain, M., & Boujday, S. (2019) · Biosensors · doi:10.3390/bios9020078 · Cited by 503
Metadata
- Authors
- Farhadi, K., Forough, M., Molaei, R., Hajizadeh, S., & Rafipour, A.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2012-01
- Volume
- 161
- Issue
- 1
- Pages
- 880-885
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2083945431
- Cited by
- 391
- References
- 27
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.