Comparative gas sensor response of SnO2, SnO and Sn3O4 nanobelts to NO2 and potential interferents
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adsorption of Gases in Multimolecular Layers
Brunauer, S., Emmett, P. H., & Teller, E. (1938) · Journal of the American Chemical Society · doi:10.1021/ja01269a023 · Cited by 28,156
VAPOR-LIQUID-SOLID MECHANISM OF SINGLE CRYSTAL GROWTH
Wagner, R. S., & Ellis, W. C. (1964) · Applied Physics Letters · doi:10.1063/1.1753975 · Cited by 6,786
Nanobelts of Semiconducting Oxides
Pan, Z. W., Dai, Z. R., & Wang, Z. L. (2001) · Science · doi:10.1126/science.1058120 · Cited by 5,823
Conduction Model of Metal Oxide Gas Sensors
Barsan, N., & Weimar, U. (2001) · Journal of Electroceramics · doi:10.1023/a:1014405811371 · Cited by 2,721
The surface and materials science of tin oxide
Batzill, M., & Diebold, U. (2005) · Progress in Surface Science · doi:10.1016/j.progsurf.2005.09.002 · Cited by 2,557
Sing, K. S. W. (1982) · Pure and Applied Chemistry · doi:10.1351/pac198254112201 · Cited by 2,091
Samsonov, G. V. (1973) · Springer eBooks · doi:10.1007/978-1-4615-9597-7 · Cited by 1,377
Toward innovations of gas sensor technology
Yamazoe, N. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.12.075 · Cited by 1,292 · cited 2×
“[3] N.”
BackgroundMetal oxide nano-crystals for gas sensing
Comini, E. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.10.069 · Cited by 717 · cited 2×
“uch devices show promise for detecting pollutant gases at ppm, nd even ppb levels, with high sensitivity, selectivity and response peed [2], thereby potentially satisfying a wide range of requireents in the safety, health, environment and energy conservation reas [3,4].”
Background(2012) · Wiley-VCH eBooks · Cited by 652
Cited by
Metal oxide nanostructures for sensor applications
Nunes, D., Pimentel, A., Gonçalves, A., Pereira, S., Branquinho, R., Barquinha, P., Fortunato, E., & Martins, R. (2019) · Semiconductor Science and Technology · doi:10.1088/1361-6641/ab011e · Cited by 354
Bai, X., Lv, H., Liu, Z., Chen, J., Wang, J., Sun, B., Zhang, Y., Wang, R., & Shi, K. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.125830 · Cited by 213
Metadata
- Authors
- Suman, P. H., Felix, A. A., Tuller, H. L., Varela, J. A., & Orlandi, M. O.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2015-03
- Volume
- 208
- Pages
- 122-127
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2004169646
- Cited by
- 168
- References
- 24
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative gas sensor response of SnO2, SnO and Sn3O4 nanobelts to NO2 and potential interferents. https://app.cochat.ai/papers/10.1016/j.snb.2014.10.119
- The paper
- Suman, P. H., Felix, A. A., Tuller, H. L., Varela, J. A., & Orlandi, M. O. (2015). Comparative gas sensor response of SnO2, SnO and Sn3O4 nanobelts to NO2 and potential interferents. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2014.10.119
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.