Cited by 48Neuroscience and Neural EngineeringConducting polymers and applicationsElectrochemical sensors and biosensors

Polymeric C-shaped cuff electrode for recording of peripheral nerve signal

Xue, Ning, Sun, Tao, Tsang, Wei Mong, Delgado-Martinez, Ignacio, Lee, Sang-Hoon, Sheshadri, Swathi, Xiang, Zhuolin, Merugu, Srinivas +3 more·2015·Sensors and Actuators B: Chemical

Integrity signals

Registry

Crossref · 10.1016/j.snb.2015.01.006

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Reducing the thickness of the substrate and the metal layer can decrease the mechanical mismatch to some extent, such as in 2D extraneural electrodes based on polyimide and parylene-C.

    “Reducing the thickness of the substrate and the metal layer can decrease the mechanical mismatch to some extent, such as the more recently developed 2D extraneural electrodes, which are based on polyimide (PI) and parylene-C (9–12).”

The citation lists haven’t been fetched yet

References 36 · Cited by 48

Authors
Xue, N., Sun, T., Tsang, W. M., Delgado-Martinez, I., Lee, S.-H., Sheshadri, S., Xiang, Z., Merugu, S., Gu, Y., Yen, S.-C., & Thakor, N. V.
Affiliations
  • Agency for Science, Technology and Research (SG)
  • National University of Singapore (SG)
  • Johns Hopkins University (US)
Corresponding author
Xue, Ning
Venue
Sensors and Actuators B: Chemical
Publisher
Elsevier BV
Published
2015-04
Volume
210
Pages
640-648
ISSN
0925-4005 (ISSN-L)
OpenAlex
W2018175586
Cited by
48
References
36
Citations by year
2026: 1 · 2025: 1 · 2024: 4 · 2023: 1 · 2022: 2 · 2021: 6 · 2020: 6 · 2019: 7 · 2018: 7 · 2017: 6 · 2016: 3 · 2015: 4
FWCI
3.10
Type
journal article
Language
en
Open access
closed
Locations
Sensors and Actuators B Chemical (publishedVersion)
Funders
  • Singapore National Research Foundation
  • SINAPSE (Singapore Institute for Neurotechnology)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
Keywords
polyimide electrodes, peripheral nerve recording, sciatic nerve, neural interfaces, platinum electrode, gold electrode, compound nerve action potential, electrochemical impedance, signal-to-noise ratio, rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review