The DOI matches its Crossref record.
Three-dimensional paper-based microfluidic chip device for multiplexed fluorescence detection of Cu2+ and Hg2+ ions based on ion imprinting technology
Open accessAbstract
In this study, a novel three-dimensional (3D) origami ion imprinted polymers microfluidic paper-based chip device for specific, sensitive and multiplexed detection of Cu2+ and Hg2+ ions has been proposed. In this device, the surface of the paper was activated by grafting with CdTe QDs through amino processing and formation of Cu2+ or Hg2+ IIPs and CdTe QDs complex that led to fluorescence quenching of QDs because the photo luminescent energy of QDs could be delivered to the complex. This method can realize the liquid phase of QDs@IIPs being transferred to the solid glass fiber paper and improve the portability of the device. Moreover, this platform allows to simultaneous detection of Cu2+ and Hg2+ ions with good selectivity and sensitivity. The proposed method reveals that the copper ion imprinted fluorescent sensor demonstrated a good linearity from 0.11 to 58.0 μg/L with the detection limit of 0.035 μg/L and the mercury ion linear range is 0.26–34.0 μg/L with detection limit of 0.056 μg/L. Importantly, this device can provide quantitative information conveniently and show great potential to be further extended to the detection of other metal ions for environmental monitoring and food safety field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Strategies of molecular imprinting-based fluorescence sensors for chemical and biological analysis
Yang, Q., Li, J., Wang, X., Peng, H., Xiong, H., & Chen, L. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.04.028 · Cited by 369
Self-citationAdvances in Paper-Based Analytical Devices
Ozer, T., McMahon, C., & Henry, C. S. (2020) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114845 · Cited by 330
Chen, Z., Zhang, Z., Qi, J., You, J., Ma, J., & Chen, L. (2023) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2022.129889 · Cited by 319
Self-citationSeparation of Protein-Binding Anthraquinones from Semen Cassiae Using Two-Stage Foam Fractionation
Ding, L., Wang, Y., Yue, C., Wu, Z., Sun, Y., Wang, M., & Li, R. (2019) · Processes · doi:10.3390/pr7070463 · Cited by 4
Metadata
- Authors
- Qi, J., Li, B., Wang, X., Zhang, Z., Wang, Z., Han, J., & Chen, L.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2017-11
- Volume
- 251
- Pages
- 224-233
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2613735432
- Cited by
- 244
- References
- 0
- FWCI
- 10.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-dimensional paper-based microfluidic chip device for multiplexed fluorescence detection of Cu2+ and Hg2+ ions based on ion imprinting technology. https://app.cochat.ai/papers/10.1016/j.snb.2017.05.052
- The paper
- Qi, J., Li, B., Wang, X., Zhang, Z., Wang, Z., Han, J., & Chen, L. (2017). Three-dimensional paper-based microfluidic chip device for multiplexed fluorescence detection of Cu2+ and Hg2+ ions based on ion imprinting technology. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2017.05.052
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.