The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ratiometric fluorescence sensor for Fe3+ ions detection based on quantum dot-doped hydrogel optical fiber
Abstract
Abstract We develop a novel ratiometric fluorescence sensor based on CdTe quantum dots (QDs) doped hydrogel optical fiber for selective and on-site detection of Fe3+ ions in real time. The hydrogel fiber is made of a core-cladding structure with a step-index profile to confine light within the core. Two types of QDs, the green emissive thioglycolic acid capped quantum dots (gQDs) and red emissive N-Acetyl- l -cysteine capped QDs (rQDs), are synthesized and incorporated in the core of the hydrogel fiber. The rQDs can be selectively quenched by the Fe3+ ions that diffuse into the hydrogel matrix while the gQDs are immune to Fe3+ ions and exhibit stable fluorescence emission. By ratiometric detection of the fluorescence intensities of the two QDs, quantitative and selective detection of Fe3+ ions is achieved in a linear range of 0–3.5 μM with a detection limit of 14 nM. The cladded hydrogel fiber doped with QDs enables efficient laser excitation and fluorescence collection in water. Our results reveal that the ratiometric sensing based on multi-QDs doped fiber can be feasibly applied for real-time and on-site analysis of heavy metal ions in aqueous environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Redox signaling and cancer: The role of “labile” iron
Galaris, D., Skiada, V., & Barbouti, A. (2008) · Cancer Letters · doi:10.1016/j.canlet.2008.02.038 · Cited by 284
Cited by
Fluorescent Sensors for the Detection of Heavy Metal Ions in Aqueous Media
De Acha, N., Elosúa, C., Corres, J., & Arregui, F. (2019) · Sensors · doi:10.3390/s19030599 · Cited by 294
Hydrogel-Based Sensor Networks: Compositions, Properties, and Applications—A Review
Sun, X., Agate, S., Salem, K. S., Lucia, L., & Pal, L. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01011 · Cited by 264
Wang, C., Shi, H., Yang, M., Yan, Y., Liu, E., Ji, Z., & Fan, J. (2020) · Materials Research Bulletin · doi:10.1016/j.materresbull.2019.110730 · Cited by 257
Metadata
- Authors
- Zhou, M., Guo, J., & Yang, C.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2018-07
- Volume
- 264
- Pages
- 52-58
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2791483323
- Cited by
- 170
- References
- 1
- FWCI
- 5.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ratiometric fluorescence sensor for Fe3+ ions detection based on quantum dot-doped hydrogel optical fiber. https://app.cochat.ai/papers/10.1016/j.snb.2018.02.119
- The paper
- Zhou, M., Guo, J., & Yang, C. (2018). Ratiometric fluorescence sensor for Fe3+ ions detection based on quantum dot-doped hydrogel optical fiber. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2018.02.119
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.