Towards conductive-gel-free electrodes: Understanding the wet electrode, semi-dry electrode and dry electrode-skin interface impedance using electrochemical impedance spectroscopy fitting
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The electrode-scalp impedance of six subjects is studied by electrochemical impedance spectroscopy using three representative electrodes, namely wet electrodes, semi-dry electrodes, and dry electrodes. With the analysis of proposed equivalent models and area-normalized impedance (kΩ cm2), the specific electrode double layer resistances are 530 Ω cm2 for all electrodes, their specific contact resistances Res are 80 Ω cm2, 114 Ω cm2 and 20,077 Ω cm2, and their specific skin resistances Rs are 867 Ω cm2, 1730 Ω cm2 and 46,145 Ω cm2 for these three representative electrodes respectively. When pressure was applied on dry electrodes, Res reduced by 47% and Rs reduced by 81%. When pressure was applied on semi-dry electrodes, Rs reduced by 50% (Res is not applicable for semi-dry electrodes). After application of scalp abrasion for dry electrodes, Res reduced by 36% and Rs reduced by 82%. After application of scalp abrasion for semi-dry electrodes, Rs reduced by 64%. Seeking novel interface materials may break through the bottleneck for dry electrodes development in terms of integrated materials, mechanical support and electronic circuitry, while semi-dry electrodes have much development space to meet a balance of quick setup, comfortable wear, and satisfactory signal quality in many medical and out-clinic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces in neurological rehabilitation
Daly, J. J., & Wolpaw, J. R. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70223-0 · Cited by 1,149
Electrodeposited polypyrrole/carbon nanotubes composite films electrodes for neural interfaces
Lu, Y., Li, T., Zhao, X., Li, M., Cao, Y., Yang, H., & Duan, Y. Y. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.022 · Cited by 191
Self-citationNovel semi-dry electrodes for brain–computer interface applications
Wang, F., Li, G., Chen, J., Duan, Y., & Zhang, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046021 · Cited by 77
Self-citation
Cited by
Skin bioelectronics towards long-term, continuous health monitoring
Wang, Y., Haick, H., Guo, S., Wang, C., Lee, S., Yokota, T., & Someya, T. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00207h · Cited by 318
Metadata
- Authors
- Li, G., Wang, S., & Duan, Y. Y.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 277
- Pages
- 250-260
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2889286786
- Cited by
- 203
- References
- 3
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Towards conductive-gel-free electrodes: Understanding the wet electrode, semi-dry electrode and dry electrode-skin interface impedance using electrochemical impedance spectroscopy fitting. https://app.cochat.ai/papers/10.1016/j.snb.2018.08.155
- The paper
- Li, G., Wang, S., & Duan, Y. Y. (2018). Towards conductive-gel-free electrodes: Understanding the wet electrode, semi-dry electrode and dry electrode-skin interface impedance using electrochemical impedance spectroscopy fitting. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2018.08.155
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.