The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Flexible and highly sensitive H2S gas sensor based on in-situ polymerized SnO2/rGO/PANI ternary nanocomposite with application in halitosis diagnosis
Abstract
Abstract A room temperature sub-ppb hydrogen sulfide (H2S) gas sensors based on tin oxide/reduced graphene oxide/polyaniline (SnO2/rGO/PANI) was synthesized by in-situ polymerization technique. The SnO2/rGO/PANI nanocomposite film was fabricated on a flexible polyethylene terephthalate (PET) substrate with interdigital electrodes (IDEs). The SnO2/rGO/PANI sensor possesses excellent sensing characteristics such as high response, fast response/recovery time, stable repeatability, outstanding selectivity and long-term stability. The response of SnO2/rGO/PANI film sensor prepared by in-situ polymerization is 23.9 toward 200 ppb H2S, which is two times higher than that of physical doping method, and the limit of detection is 50 ppb. The experimental result reveals that the SnO2/rGO/PANI sensor is an excellent candidate to detect H2S gas in exhaled human breath for early diagnosis of halitosis. The underlying sensing mechanism of the SnO2/rGO/PANI sensing device towards H2S gas is due to the high surface area of SnO2/rGO/PANI film, chemisorption of oxygen on surface of SnO2 hollow spheres and the special role of heterojunction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Song, Z., Wei, Z., Wang, B., Luo, Z., Xu, S., Zhang, W., Yu, H., Li, M., Huang, Z., Zang, J., et al. (2016) · Chemistry of Materials · doi:10.1021/acs.chemmater.5b04850 · Cited by 438
Cited by
Paper-Based Sensors for Gas, Humidity, and Strain Detections: A Review
Tai, H., Duan, Z., Wang, Y., Wang, S., & Jiang, Y. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c06435 · Cited by 441
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Peng, B., Zhao, F., Ping, J., & Ying, Y. (2020) · Small · doi:10.1002/smll.202002681 · Cited by 224
Ultrasensitive detection of hydrogen sulfide gas based on perovskite vertical channel chemo-sensor
Lee, K.-Y., Hsieh, J.-C., Chen, C.-A., Chen, W.-L., Meng, H.-F., Lu, C.-J., Horng, S.-F., & Zan, H.-W. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128988 · Cited by 46
Chen, T.-W., Ramachandran, R., Chen, S.-M., Anushya, G., & Ramachandran, K. (2020) · Sensors · doi:10.3390/s20236755 · Cited by 37
Metadata
- Authors
- Zhang, D., Wu, Z., & Zong, X.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2019-06
- Volume
- 289
- Pages
- 32-41
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2921054451
- Cited by
- 264
- References
- 1
- FWCI
- 12.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible and highly sensitive H2S gas sensor based on in-situ polymerized SnO2/rGO/PANI ternary nanocomposite with application in halitosis diagnosis. https://app.cochat.ai/papers/10.1016/j.snb.2019.03.055
- The paper
- Zhang, D., Wu, Z., & Zong, X. (2019). Flexible and highly sensitive H2S gas sensor based on in-situ polymerized SnO2/rGO/PANI ternary nanocomposite with application in halitosis diagnosis. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2019.03.055
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.