Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 211

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Hierarchical porous MXene/amino carbon nanotubes-based molecular imprinting sensor for highly sensitive and selective sensing of fisetin

Open access
Ma, Xue, Tu, Xiaolong, Gao, Feng, Xie, Yu, Huang, Xigen, Fernandez, Carlos, Qu, Fengli, Liu, Guangbin, Lu, Limin, Yu, Yongfang·2020·Sensors and Actuators B: Chemical

Abstract

Abstract In this work, a highly selective and sensitive electrochemical sensor based on hierarchical porous MXene/amino carbon nanotubes (MXene/NH2-CNTs) composite and molecularly imprinted polymer (MIP) was developed for fisetin detection. The porous MXene/NH2-CNTs films were fabricated by self-assembly of negatively charged Ti3C2Tx MXene flakes and positively charged NH2-CNTs. The utilization of conductive NH2-CNTs as interlayer spacers efficiently inhibited the aggregation of MXene flakes and formed a well-defined porous structure, as a result of increasing the effective surface area, an enhancement of the electrical conductivity and electrocatalytic activity was observed. This sensor takes advantages of molecularly imprinted technique and MXene/NH2-CNTs nanomaterials to achieve high selectivity and high sensitivity for the determination of fisetin. The factors that affect sensor response were studied and optimized. The as-prepared molecular imprinting sensor, under the optimized conditions, presented a good linear relationship with the fisetin concentration ranging from 0.003 μmol L−1 to 20.0 μmol L−1 with a limit of detection (LOD) of 1.0 nmol L−1. Besides, with favorable stability and selectivity, this newly developed sensor was utilized for the detection of fisetin in actual samples with satisfactory results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.snb.2020.127815

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 211

Metadata

Authors
Ma, X., Tu, X., Gao, F., Xie, Y., Huang, X., Fernandez, C., Qu, F., Liu, G., Lu, L., & Yu, Y.
Venue
Sensors and Actuators B: Chemical
Publisher
Elsevier BV
Published
2020-04
Volume
309
Pages
127815
ISSN
0925-4005 (ISSN-L)
OpenAlex
W3005372498
Cited by
211
References
2
FWCI
10.38
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Hierarchical porous MXene/amino carbon nanotubes-based molecular imprinting sensor for highly sensitive and selective sensing of fisetin. https://app.cochat.ai/papers/10.1016/j.snb.2020.127815
The paper
Ma, X., Tu, X., Gao, F., Xie, Y., Huang, X., Fernandez, C., Qu, F., Liu, G., Lu, L., & Yu, Y. (2020). Hierarchical porous MXene/amino carbon nanotubes-based molecular imprinting sensor for highly sensitive and selective sensing of fisetin. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2020.127815

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.