Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 206

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Ultrasensitive flexible NH3 gas sensor based on polyaniline/SrGe4O9 nanocomposite with ppt-level detection ability at room temperature

Zhang, Yajie, Zhang, Junxin, Jiang, Yadong, Duan, Zaihua, Liu, Bohao, Zhao, Qiuni, Wang, Si, Yuan, Zhen, Tai, Huiling·2020·Sensors and Actuators B: Chemical

Abstract

Abstract Detection limit as an important parameter of gas sensors, much effort has been devoted to developing high-performance gas sensors with low detection limit. However, the development of gas sensors with ppt-level detection limit still faces enormous challenges. In this work, a flexible and ultra-highly sensitive ammonia (NH3) sensor based on polyaniline/SrGe4O9 nanocomposites (PSN) was successfully fabricated via a facile in situ chemical oxidation polymerization method. When exposed to 0.2–10 ppm NH3 at 25 °C in 60% relative humidity (RH), the PSN sensor showed larger sensitivity (20.59% ppm−1) than that of PANI sensor (9.82% ppm−1). The response of the PSN sensor (16%) was two-fold higher than that of the PANI one (8%) to 0.2 ppm NH3 at room temperature. Meanwhile, the response time of the PSN sensor (24 s) was reduced to up to a third of that of the PANI sensor (64 s) for 800 ppb NH3. Additionally, the flexible PSN sensor exhibited good reproducibility, satisfactory long-term stability, excellent selectivity and outstanding flexibility to NH3 at room temperature. Significantly, the PSN sensor presented the ultra-low detection limit of 250 ppt toward NH3. Such outstanding gas-sensing properties were attributed to the unique hierarchical architecture with abundant mesoporous and the formation of p-n heterojunction at the interface between p-type PANI and n-type SrGe4O9. This research provides new strategies for developing high-performance NH3 sensors with supersensitive and ultra-low detection limit.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.snb.2020.128293

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 206

Metadata

Authors
Zhang, Y., Zhang, J., Jiang, Y., Duan, Z., Liu, B., Zhao, Q., Wang, S., Yuan, Z., & Tai, H.
Venue
Sensors and Actuators B: Chemical
Publisher
Elsevier BV
Published
2020-09
Volume
319
Pages
128293
ISSN
0925-4005 (ISSN-L)
OpenAlex
W3024711799
Cited by
206
References
1
FWCI
10.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasensitive flexible NH3 gas sensor based on polyaniline/SrGe4O9 nanocomposite with ppt-level detection ability at room temperature. https://app.cochat.ai/papers/10.1016/j.snb.2020.128293
The paper
Zhang, Y., Zhang, J., Jiang, Y., Duan, Z., Liu, B., Zhao, Q., Wang, S., Yuan, Z., & Tai, H. (2020). Ultrasensitive flexible NH3 gas sensor based on polyaniline/SrGe4O9 nanocomposite with ppt-level detection ability at room temperature. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2020.128293

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.