The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A facile PDMS coating approach to room-temperature gas sensors with high humidity resistance and long-term stability
Abstract
The interference from relative humidity (RH) poses a critical issue for the practical application of room-temperature gas sensors. We demonstrate herein coating gas sensors with a hydrophobic polydimethylsiloxane (PDMS) layer can significantly enhance their humidity resistance. Pd nanoparticles (NPs) decorated TiO2 nanotubes (Pd/TiO2 NTs) is selected as a typical room-temperature gas sensor. By a simple thermal evaporation process, a conformal PDMS layer can be coated on the nanostructured sensing material. PDMS layer not only endows the sensor with a hydrophobic surface to water droplet, but also has a sufficient thickness to effectively prevent the penetration of water molecules. In contrast, other hydrophobic modification layer (such as silane coupling agent) can only make gas sensors superhydrophobic but not able to enhance their humidity resistance. Additionally, PDMS layer improves the long-term stability of Pd/TiO2 NTs sensors through affording protection of Pd NPs on the surface of gas sensors. Furthermore, PDMS layer is stable enough to resist the degradation during long-term usage. The PDMS coating strategy is simple and can be applied to gas sensors with various morphologies, which promotes the real applications of room-temperature gas sensors in moist environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metallic Ti3C2T x MXene Gas Sensors with Ultrahigh Signal-to-Noise Ratio
Kim, S. J., Koh, H.-J., Ren, C. E., Kwon, O., Maleski, K., Cho, S.-Y., Anasori, B., Kim, C.-K., Choi, Y.-K., Kim, J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07460 · Cited by 1,699
Cited by
Polydimethylsiloxane Composites Characterization and Its Applications: A Review
Ariati, R., Sales, F., Souza, A., Lima, R. A., & Ribeiro, J. (2021) · Polymers · doi:10.3390/polym13234258 · Cited by 440
Metadata
- Authors
- Gao, Z., Song, G., Zhang, X., Li, Q., Yang, S., Wang, T., Li, Y., Zhang, L., Guo, L., & Fu, Y.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2020-12
- Volume
- 325
- Pages
- 128810
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W3082485318
- Cited by
- 167
- References
- 1
- FWCI
- 5.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A facile PDMS coating approach to room-temperature gas sensors with high humidity resistance and long-term stability. https://app.cochat.ai/papers/10.1016/j.snb.2020.128810
- The paper
- Gao, Z., Song, G., Zhang, X., Li, Q., Yang, S., Wang, T., Li, Y., Zhang, L., Guo, L., & Fu, Y. (2020). A facile PDMS coating approach to room-temperature gas sensors with high humidity resistance and long-term stability. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2020.128810
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.