Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 6

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Carbon nanodots modified-electrode for peroxide-free cholesterol biosensing and biofuel cell design

del Barrio, Melisa, Martínez-Periñán, Emiliano, Gutiérrez-Sánchez, Cristina, Mateo-Martí, Eva, Pita, Marcos, De Lacey, Antonio L., Pariente, Félix, Lorenzo, Encarnación · 2023 · Sensors and Actuators B: Chemical

Abstract

The determination of cholesterol is greatly important because high concentrations of this biomarker are associated to heart disease. Moreover, cholesterol can be used as a fuel in enzymatic fuel cells operating under physiological conditions. Here, we present a cholesterol biosensor and a peroxide-free biofuel cell based on the electrocatalytic oxidation of the NADH generated during the enzymatic reaction of cholesterol dehydrogenase (ChDH) as an alternative to the H2O2 biosensing strategies used with cholesterol oxidase-bioelectrodes. Azure A functionalized-carbon nanodots were used as NADH oxidation electrocatalysts and for ChDH covalent immobilization. The biosensor responded linearly to cholesterol concentrations up to 1.7 mM with good sensitivity (4.50 mA cm−2 M−1) and at a low potential. The ChDH bioelectrode was combined with an O2-reducing bilirubin oxidase cathode to produce electrical energy using cholesterol as fuel and O2 as oxidant. Furthermore, the resulting enzymatic fuel cell was tested in human serum naturally containing free cholesterol.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.snb.2022.132895

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 48

  1. Murray, 2003, Effectiveness and costs of interventions to lower systolic blood pressure and cholesterol: a global and regional analysis on reduction of cardiovascular-disease risk, Lancet, 361, 717, 10.1016/S0140-6736(03)12655-4 · DOI · Paper page
  2. Libby, 2019, Atherosclerosis, Nat. Rev. Dis. Prim., 5, 56, 10.1038/s41572-019-0106-z · DOI · Paper page
  3. Wang, 2020, Review – enzymatic strips for detection of serum total cholesterol with point-of-care testing (POCT) devices: current status and future prospect, J. Electrochem. Soc., 167
  4. De Backer, 2003, Eur. Heart J., 24, 1601, 10.1016/S0195-668X(03)00347-6 · DOI · Paper page
  5. MacLachlan, 2000, Cholesterol oxidase: sources, physical properties and analytical applications, J. Steroid Biochem. Mol. Biol., 72, 169, 10.1016/S0960-0760(00)00044-3 · DOI · Paper page
  6. Arya, 2008, Recent advances in cholesterol biosensor, Biosens. Bioelectron., 23, 1083, 10.1016/j.bios.2007.10.018 · DOI · Paper page
  7. Thakur, 2021, Ultrasensitive electrochemical biosensors for dopamine and cholesterol: recent advances, challenges and strategies, Chem. Commun., 57, 13084, 10.1039/D1CC05271C · DOI
  8. Shen, 2007, Development of a screen-printed cholesterol biosensor: comparing the performance of gold and platinum as the working electrode material and fabrication using a self-assembly approach, Sens. Actuators B: Chem., 120, 417, 10.1016/j.snb.2006.02.035 · doi:10.1016/j.snb.2006.02.035
  9. Rahman, 2014, A cholesterol biosensor based on a bi-enzyme immobilized on conducting poly(thionine) film, Sens. Actuators B: Chem., 202, 536, 10.1016/j.snb.2014.05.114 · DOI
  10. Kaur, 2018, Development of a microfluidic electrochemical biosensor: prospect for point-of-care cholesterol monitoring, Sens. Actuators B: Chem., 261, 460, 10.1016/j.snb.2018.01.144 · DOI · Paper page
  11. Ruecha, 2014, Novel paper-based cholesterol biosensor using graphene/polyvinylpyrrolidone/polyaniline nanocomposite, Biosens. Bioelectron., 52, 13, 10.1016/j.bios.2013.08.018 · DOI · Paper page
  12. Shumyantseva, 2004, Cholesterol amperometric biosensor based on cytochrome P450scc, Biosens. Bioelectron., 19, 971, 10.1016/j.bios.2003.09.001 · DOI
  13. Quah, 2017, Cholesterol as a promising alternative energy source: bioelectrocatalytic oxidation using NAD-dependent cholesterol dehydrogenase in human serum, J. Electrochem. Soc., 164, H3024, 10.1149/2.0021703jes · DOI
  14. Mano, 2001, Adsorption and catalytic activity of trinitro-fluorenone derivatives towards NADH oxidation on different electrode materials, Electrochem. Commun., 3, 585, 10.1016/S1388-2481(01)00224-7 · doi:10.1016/s1388-2481(01)00224-7
  15. Maleki, 2012, Electrodeposition of catechol on glassy carbon electrode and its electrocatalytic activity toward NADH oxidation, Electroanalysis, 24, 1932, 10.1002/elan.201200251 · DOI
  16. Gorton, 2002, Electrocatalytic oxidation of NAD(P)H at mediator-modified electrodes, Rev. Mol. Biotechnol., 82, 371, 10.1016/S1389-0352(01)00053-8 · DOI · Paper page
  17. Revenga-Parra, 2012, Grafted Azure A modified electrodes as disposable β-nicotinamide adenine dinucleotide sensors, Anal. Chim. Acta, 747, 84, 10.1016/j.aca.2012.07.043 · doi:10.1016/j.aca.2012.07.043
  18. Doumèche, 2010, NADH oxidation on screen-printed electrode modified with a new phenothiazine diazonium salt, Electrochem. Commun., 12, 1398, 10.1016/j.elecom.2010.07.031 · doi:10.1016/j.elecom.2010.07.031
  19. Abdellaoui, 2013, Rapid electrochemical screening of NAD-dependent dehydrogenases in a 96-well format, Chem. Commun., 49, 5781, 10.1039/c3cc42065e · doi:10.1039/c3cc42065e
  20. Gonzalez-Solino, 2018, Enzymatic fuel cells: towards self-powered implantable and wearable diagnostics, Biosensors, 8, 11, 10.3390/bios8010011 · DOI
  21. Rasmussen, 2016, Enzymatic biofuel cells: 30 years of critical advancements, Biosens. Bioelectron., 76, 91, 10.1016/j.bios.2015.06.029 · DOI · Paper page
  22. Mano, 2018, O2 reduction in enzymatic biofuel cells, Chem. Rev., 118, 2392, 10.1021/acs.chemrev.7b00220 · DOI · Paper page
  23. Ohara, 1993, Bienzyme sensors based on “electrically wired” peroxidase, Electroanalysis, 5, 825, 10.1002/elan.1140050917 · DOI
  24. Conzuelo, 2018, Self-powered bioelectrochemical devices, Curr. Opin. Electrochem., 12, 156, 10.1016/j.coelec.2018.05.010 · DOI
  25. Katz, 2001, Self-powered enzyme-based biosensors, J. Am. Chem. Soc., 123, 10752, 10.1021/ja0167102 · DOI · Paper page
  26. Falk, 2014, Self-powered wireless carbohydrate/oxygen sensitive biodevice based on radio signal transmission, PLOS One, 9, 1, 10.1371/journal.pone.0109104 · DOI
  27. Zhou, 2015, Recent progress on the development of biofuel cells for self-powered electrochemical biosensing and logic biosensing: a review, Electroanalysis, 27, 10.1002/elan.201500173 · DOI
  28. Ruff, 2017, A self‐powered ethanol biosensor, ChemElectroChem, 4, 890, 10.1002/celc.201600864 · DOI
  29. Moreira, 2017, Towards timely Alzheimer diagnosis: a self-powered amperometric biosensor for the neurotransmitter acetylcholine, Biosens. Bioelectron., 87, 607, 10.1016/j.bios.2016.08.104 · DOI
  30. Fu, 2018, Recent advances in the construction of biofuel cells based self‐powered electrochemical biosensors: a review, Electroanalysis, 30, 2535, 10.1002/elan.201800487 · DOI
  31. Sekretaryova, 2014, Cholesterol self-powered biosensor, Anal. Chem., 86, 9540, 10.1021/ac501699p · DOI · Paper page
  32. Campuzano, 2019, Carbon dots and graphene quantum dots in electrochemical biosensing, Nanomaterials, 9, 10.3390/nano9040634 · DOI · Paper page
  33. Hassanvand, 2021, Carbon nanodots in electrochemical sensors and biosensors: a review, ChemElectroChem, 8, 15, 10.1002/celc.202001229 · DOI
  34. Xiao, 2018, Novel properties and applications of carbon nanodots, Nanoscale Horiz., 3, 565, 10.1039/C8NH00106E · DOI · Paper page
  35. Martínez-Periñán, 2022, Neutral Red-carbon nanodots for selective fluorescent DNA sensing, Anal. Bioanal. Chem., 10.1007/s00216-022-03980-1 · doi:10.1007/s00216-022-03980-1
  36. Martínez-Periñán, 2021, A MoS2 platform and thionine-carbon nanodots for sensitive and selective detection of pathogens, Biosens. Bioelectron., 189, 10.1016/j.bios.2021.113375 · doi:10.1016/j.bios.2021.113375
  37. Vidal, 2004, Amperometric cholesterol biosensors based on the electropolymerization of pyrrole and the electrocatalytic effect of Prussian-Blue layers helped with self-assembled monolayers, Talanta, 64, 655, 10.1016/j.talanta.2004.03.038 · DOI
  38. Kishi, 2000, The characteristics and applications of recombinant cholesterol dehydrogenase, Biosci. Biotechnol. Biochem., 64, 1352, 10.1271/bbb.64.1352 · doi:10.1271/bbb.64.1352
  39. Guerrero-Esteban, 2021, Sensitive glyphosate electrochemiluminescence immunosensor based on electrografted carbon nanodots, Sens. Actuators B: Chem., 330, 10.1016/j.snb.2020.129389 · doi:10.1016/j.snb.2020.129389
  40. Gutiérrez-Sánchez, 2013, Bilirubin oxidase-based nanobiocathode working in serum-mimic buffer for implantable biofuel cell, Electroanalysis, 25, 1359, 10.1002/elan.201200668 · DOI
  41. Mostazo-López, 2020, Nitrogen doped superactivated carbons prepared at mild conditions as electrodes for supercapacitors in organic electrolyte, C, 6
  42. Liu, 2015, High N-content holey few-layered graphene electrocatalysts: scalable solvent-less production, J. Mater. Chem. A, 3, 1682, 10.1039/C4TA05008H · DOI
  43. Susi, 2015, X-ray photoelectron spectroscopy of graphitic carbon nanomaterials doped with heteroatoms, Beilstein J. Nanotechnol., 6, 177, 10.3762/bjnano.6.17 · DOI · Paper page
  44. Gutiérrez-Sánchez, 2020, Direct covalent immobilization of new nitrogen-doped carbon nanodots by electrografting for sensing applications, Carbon, 159, 303, 10.1016/j.carbon.2019.12.053 · DOI
  45. Geto, 2013, Electrochemical determination of berberine at a multi-walled carbon nanotubes-modified glassy carbon electrode, Sens. Actuators B: Chem., 183, 96, 10.1016/j.snb.2013.03.121 · doi:10.1016/j.snb.2013.03.121
  46. Crapnell, 2021, Electroanalytical overview: utilising micro- and nano-dimensional sized materials in electrochemical-based biosensing platforms, Mikrochim. Acta, 188, 268, 10.1007/s00604-021-04913-y · DOI
  47. Fang, 2011, A disposable amperometric biosensor for determining total cholesterol in whole blood, Sens. Actuators B-Chem., 155, 545, 10.1016/j.snb.2011.01.005 · doi:10.1016/j.snb.2011.01.005
  48. Milton, 2014, Bilirubin oxidase bioelectrocatalytic cathodes: the impact of hydrogen peroxide, Chem. Commun., 50, 94, 10.1039/C3CC47689H · DOI

Metadata

Authors
del Barrio, M., Martínez-Periñán, E., Gutiérrez-Sánchez, C., Mateo-Martí, E., Pita, M., De Lacey, A. L., Pariente, F., & Lorenzo, E.
Venue
Sensors and Actuators B: Chemical
Publisher
Elsevier BV
Published
2023-01
Volume
375
Pages
132895
ISSN
0925-4005
Cited by
6
References
1
Language
en
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Carbon nanodots modified-electrode for peroxide-free cholesterol biosensing and biofuel cell design. https://app.cochat.ai/papers/10.1016/j.snb.2022.132895
The paper
del Barrio, M., Martínez-Periñán, E., Gutiérrez-Sánchez, C., Mateo-Martí, E., Pita, M., De Lacey, A. L., Pariente, F., & Lorenzo, E. (2023). Carbon nanodots modified-electrode for peroxide-free cholesterol biosensing and biofuel cell design. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2022.132895

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).