The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Carbon nanodots modified-electrode for peroxide-free cholesterol biosensing and biofuel cell design
Abstract
The determination of cholesterol is greatly important because high concentrations of this biomarker are associated to heart disease. Moreover, cholesterol can be used as a fuel in enzymatic fuel cells operating under physiological conditions. Here, we present a cholesterol biosensor and a peroxide-free biofuel cell based on the electrocatalytic oxidation of the NADH generated during the enzymatic reaction of cholesterol dehydrogenase (ChDH) as an alternative to the H2O2 biosensing strategies used with cholesterol oxidase-bioelectrodes. Azure A functionalized-carbon nanodots were used as NADH oxidation electrocatalysts and for ChDH covalent immobilization. The biosensor responded linearly to cholesterol concentrations up to 1.7 mM with good sensitivity (4.50 mA cm−2 M−1) and at a low potential. The ChDH bioelectrode was combined with an O2-reducing bilirubin oxidase cathode to produce electrical energy using cholesterol as fuel and O2 as oxidant. Furthermore, the resulting enzymatic fuel cell was tested in human serum naturally containing free cholesterol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Verschuren, W. M. M. (1995) · JAMA · doi:10.1001/jama.1995.03530020049031 · Cited by 573
Research works printed but not linked: 48
- Murray, 2003, Effectiveness and costs of interventions to lower systolic blood pressure and cholesterol: a global and regional analysis on reduction of cardiovascular-disease risk, Lancet, 361, 717, 10.1016/S0140-6736(03)12655-4 · DOI · Paper page
- Libby, 2019, Atherosclerosis, Nat. Rev. Dis. Prim., 5, 56, 10.1038/s41572-019-0106-z · DOI · Paper page
- Wang, 2020, Review – enzymatic strips for detection of serum total cholesterol with point-of-care testing (POCT) devices: current status and future prospect, J. Electrochem. Soc., 167
- De Backer, 2003, Eur. Heart J., 24, 1601, 10.1016/S0195-668X(03)00347-6 · DOI · Paper page
- MacLachlan, 2000, Cholesterol oxidase: sources, physical properties and analytical applications, J. Steroid Biochem. Mol. Biol., 72, 169, 10.1016/S0960-0760(00)00044-3 · DOI · Paper page
- Arya, 2008, Recent advances in cholesterol biosensor, Biosens. Bioelectron., 23, 1083, 10.1016/j.bios.2007.10.018 · DOI · Paper page
- Thakur, 2021, Ultrasensitive electrochemical biosensors for dopamine and cholesterol: recent advances, challenges and strategies, Chem. Commun., 57, 13084, 10.1039/D1CC05271C · DOI
- Shen, 2007, Development of a screen-printed cholesterol biosensor: comparing the performance of gold and platinum as the working electrode material and fabrication using a self-assembly approach, Sens. Actuators B: Chem., 120, 417, 10.1016/j.snb.2006.02.035 · doi:10.1016/j.snb.2006.02.035
- Rahman, 2014, A cholesterol biosensor based on a bi-enzyme immobilized on conducting poly(thionine) film, Sens. Actuators B: Chem., 202, 536, 10.1016/j.snb.2014.05.114 · DOI
- Kaur, 2018, Development of a microfluidic electrochemical biosensor: prospect for point-of-care cholesterol monitoring, Sens. Actuators B: Chem., 261, 460, 10.1016/j.snb.2018.01.144 · DOI · Paper page
- Ruecha, 2014, Novel paper-based cholesterol biosensor using graphene/polyvinylpyrrolidone/polyaniline nanocomposite, Biosens. Bioelectron., 52, 13, 10.1016/j.bios.2013.08.018 · DOI · Paper page
- Shumyantseva, 2004, Cholesterol amperometric biosensor based on cytochrome P450scc, Biosens. Bioelectron., 19, 971, 10.1016/j.bios.2003.09.001 · DOI
- Quah, 2017, Cholesterol as a promising alternative energy source: bioelectrocatalytic oxidation using NAD-dependent cholesterol dehydrogenase in human serum, J. Electrochem. Soc., 164, H3024, 10.1149/2.0021703jes · DOI
- Mano, 2001, Adsorption and catalytic activity of trinitro-fluorenone derivatives towards NADH oxidation on different electrode materials, Electrochem. Commun., 3, 585, 10.1016/S1388-2481(01)00224-7 · doi:10.1016/s1388-2481(01)00224-7
- Maleki, 2012, Electrodeposition of catechol on glassy carbon electrode and its electrocatalytic activity toward NADH oxidation, Electroanalysis, 24, 1932, 10.1002/elan.201200251 · DOI
- Gorton, 2002, Electrocatalytic oxidation of NAD(P)H at mediator-modified electrodes, Rev. Mol. Biotechnol., 82, 371, 10.1016/S1389-0352(01)00053-8 · DOI · Paper page
- Revenga-Parra, 2012, Grafted Azure A modified electrodes as disposable β-nicotinamide adenine dinucleotide sensors, Anal. Chim. Acta, 747, 84, 10.1016/j.aca.2012.07.043 · doi:10.1016/j.aca.2012.07.043
- Doumèche, 2010, NADH oxidation on screen-printed electrode modified with a new phenothiazine diazonium salt, Electrochem. Commun., 12, 1398, 10.1016/j.elecom.2010.07.031 · doi:10.1016/j.elecom.2010.07.031
- Abdellaoui, 2013, Rapid electrochemical screening of NAD-dependent dehydrogenases in a 96-well format, Chem. Commun., 49, 5781, 10.1039/c3cc42065e · doi:10.1039/c3cc42065e
- Gonzalez-Solino, 2018, Enzymatic fuel cells: towards self-powered implantable and wearable diagnostics, Biosensors, 8, 11, 10.3390/bios8010011 · DOI
- Rasmussen, 2016, Enzymatic biofuel cells: 30 years of critical advancements, Biosens. Bioelectron., 76, 91, 10.1016/j.bios.2015.06.029 · DOI · Paper page
- Mano, 2018, O2 reduction in enzymatic biofuel cells, Chem. Rev., 118, 2392, 10.1021/acs.chemrev.7b00220 · DOI · Paper page
- Ohara, 1993, Bienzyme sensors based on “electrically wired” peroxidase, Electroanalysis, 5, 825, 10.1002/elan.1140050917 · DOI
- Conzuelo, 2018, Self-powered bioelectrochemical devices, Curr. Opin. Electrochem., 12, 156, 10.1016/j.coelec.2018.05.010 · DOI
- Katz, 2001, Self-powered enzyme-based biosensors, J. Am. Chem. Soc., 123, 10752, 10.1021/ja0167102 · DOI · Paper page
- Falk, 2014, Self-powered wireless carbohydrate/oxygen sensitive biodevice based on radio signal transmission, PLOS One, 9, 1, 10.1371/journal.pone.0109104 · DOI
- Zhou, 2015, Recent progress on the development of biofuel cells for self-powered electrochemical biosensing and logic biosensing: a review, Electroanalysis, 27, 10.1002/elan.201500173 · DOI
- Ruff, 2017, A self‐powered ethanol biosensor, ChemElectroChem, 4, 890, 10.1002/celc.201600864 · DOI
- Moreira, 2017, Towards timely Alzheimer diagnosis: a self-powered amperometric biosensor for the neurotransmitter acetylcholine, Biosens. Bioelectron., 87, 607, 10.1016/j.bios.2016.08.104 · DOI
- Fu, 2018, Recent advances in the construction of biofuel cells based self‐powered electrochemical biosensors: a review, Electroanalysis, 30, 2535, 10.1002/elan.201800487 · DOI
- Sekretaryova, 2014, Cholesterol self-powered biosensor, Anal. Chem., 86, 9540, 10.1021/ac501699p · DOI · Paper page
- Campuzano, 2019, Carbon dots and graphene quantum dots in electrochemical biosensing, Nanomaterials, 9, 10.3390/nano9040634 · DOI · Paper page
- Hassanvand, 2021, Carbon nanodots in electrochemical sensors and biosensors: a review, ChemElectroChem, 8, 15, 10.1002/celc.202001229 · DOI
- Xiao, 2018, Novel properties and applications of carbon nanodots, Nanoscale Horiz., 3, 565, 10.1039/C8NH00106E · DOI · Paper page
- Martínez-Periñán, 2022, Neutral Red-carbon nanodots for selective fluorescent DNA sensing, Anal. Bioanal. Chem., 10.1007/s00216-022-03980-1 · doi:10.1007/s00216-022-03980-1
- Martínez-Periñán, 2021, A MoS2 platform and thionine-carbon nanodots for sensitive and selective detection of pathogens, Biosens. Bioelectron., 189, 10.1016/j.bios.2021.113375 · doi:10.1016/j.bios.2021.113375
- Vidal, 2004, Amperometric cholesterol biosensors based on the electropolymerization of pyrrole and the electrocatalytic effect of Prussian-Blue layers helped with self-assembled monolayers, Talanta, 64, 655, 10.1016/j.talanta.2004.03.038 · DOI
- Kishi, 2000, The characteristics and applications of recombinant cholesterol dehydrogenase, Biosci. Biotechnol. Biochem., 64, 1352, 10.1271/bbb.64.1352 · doi:10.1271/bbb.64.1352
- Guerrero-Esteban, 2021, Sensitive glyphosate electrochemiluminescence immunosensor based on electrografted carbon nanodots, Sens. Actuators B: Chem., 330, 10.1016/j.snb.2020.129389 · doi:10.1016/j.snb.2020.129389
- Gutiérrez-Sánchez, 2013, Bilirubin oxidase-based nanobiocathode working in serum-mimic buffer for implantable biofuel cell, Electroanalysis, 25, 1359, 10.1002/elan.201200668 · DOI
- Mostazo-López, 2020, Nitrogen doped superactivated carbons prepared at mild conditions as electrodes for supercapacitors in organic electrolyte, C, 6
- Liu, 2015, High N-content holey few-layered graphene electrocatalysts: scalable solvent-less production, J. Mater. Chem. A, 3, 1682, 10.1039/C4TA05008H · DOI
- Susi, 2015, X-ray photoelectron spectroscopy of graphitic carbon nanomaterials doped with heteroatoms, Beilstein J. Nanotechnol., 6, 177, 10.3762/bjnano.6.17 · DOI · Paper page
- Gutiérrez-Sánchez, 2020, Direct covalent immobilization of new nitrogen-doped carbon nanodots by electrografting for sensing applications, Carbon, 159, 303, 10.1016/j.carbon.2019.12.053 · DOI
- Geto, 2013, Electrochemical determination of berberine at a multi-walled carbon nanotubes-modified glassy carbon electrode, Sens. Actuators B: Chem., 183, 96, 10.1016/j.snb.2013.03.121 · doi:10.1016/j.snb.2013.03.121
- Crapnell, 2021, Electroanalytical overview: utilising micro- and nano-dimensional sized materials in electrochemical-based biosensing platforms, Mikrochim. Acta, 188, 268, 10.1007/s00604-021-04913-y · DOI
- Fang, 2011, A disposable amperometric biosensor for determining total cholesterol in whole blood, Sens. Actuators B-Chem., 155, 545, 10.1016/j.snb.2011.01.005 · doi:10.1016/j.snb.2011.01.005
- Milton, 2014, Bilirubin oxidase bioelectrocatalytic cathodes: the impact of hydrogen peroxide, Chem. Commun., 50, 94, 10.1039/C3CC47689H · DOI
Metadata
- Authors
- del Barrio, M., Martínez-Periñán, E., Gutiérrez-Sánchez, C., Mateo-Martí, E., Pita, M., De Lacey, A. L., Pariente, F., & Lorenzo, E.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2023-01
- Volume
- 375
- Pages
- 132895
- ISSN
- 0925-4005
- Cited by
- 6
- References
- 1
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carbon nanodots modified-electrode for peroxide-free cholesterol biosensing and biofuel cell design. https://app.cochat.ai/papers/10.1016/j.snb.2022.132895
- The paper
- del Barrio, M., Martínez-Periñán, E., Gutiérrez-Sánchez, C., Mateo-Martí, E., Pita, M., De Lacey, A. L., Pariente, F., & Lorenzo, E. (2023). Carbon nanodots modified-electrode for peroxide-free cholesterol biosensing and biofuel cell design. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2022.132895
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.