Exaggerated glucagon-like peptide-1 and blunted glucose-dependent insulinotropic peptide secretion are associated with Roux-en-Y gastric bypass but not adjustable gastric banding
Open accessAbstract
Background The aim of this study was to measure the circulating levels of glucagon-like peptide-1 (GLP-1), glucose-dependent insulinotropic peptide (GIP), and glucagon in patients who had undergone adjustable gastric banding (BND) or Roux-en-Y gastric bypass (RYGB) to understand the differences in glucose and insulin regulation after these procedures.Methods This was a cross-sectional study of 3 groups of women matched for age and body mass index: group 1, overweight controls (n = 13); group 2, BND (n = 10); and group 3, RYGB (n = 13). Venous blood was drawn with the patient in the fasted state and throughout a 3-hour period after a liquid meal.Results The fasting glucose level was similar between the 2 surgery groups; however, the fasting insulin concentrations were greater in the BND (10.0 microU/mL) than in the RYGB (6.2 microU/mL; P <0.05) group. The glucose level at 60 minutes was significantly lower in the RYGB group (70 mg/dL, range 38-82) than in the BND group (83 mg/dL, range 63-98). The GLP-1 levels at 30 minutes were more than threefold greater in the RYGB group (96 pmol/L) compared with the BND and overweight control (28 pmol/L) groups. The GLP-1 and insulin concentrations correlated at 30 minutes only in the RYGB group (r = .66; P = .013). The glucose-dependent insulinotropic peptide levels at 30 minutes were lower in the RYGB group (20 pmol/L) than in the BND group (31 pmol/L) or overweight control group (33 pmol/L). The peak glucagon levels were similar among the 3 groups.Conclusion Exaggerated postprandial GLP-1 and blunted glucose-dependent insulinotropic peptide secretion after RYGB might contribute to the greater weight loss and improved glucose homeostasis compared with BND.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The relatively higher postprandial insulin responses seen in patients after gastric bypass are not a response to insulin resistance or the result of general hypersensitivity of β-cells to glucose.
“These findings suggest that the relatively higher postprandial insulin responses seen in patients after GB (8,9,12,23) are not a response to insulin resistance or the result of general hypersensitivity of β-cells to glucose.”
From Gastric Bypass Surgery Enhances Glucagon-Like Peptide 1–Stimulated Postprandial Insulin Secretion in Humans (2011) · cites this paper as [8]
Gastric bypass subjects have elevated plasma concentrations of GLP-1.
“GB subjects have elevated plasma concentrations of GLP-1 (6,8–13).”
From Gastric Bypass Surgery Enhances Glucagon-Like Peptide 1–Stimulated Postprandial Insulin Secretion in Humans (2011) · cites this paper as [8]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 26 · Cited by 344
- Authors
- Korner, J., Bessler, M., Inabnet, W., Taveras, C., & Holst, J. J.
- Affiliations
- Columbia University (US)
- Columbia University Irving Medical Center (US)
- University of Copenhagen (DK)
- Venue
- Surgery for Obesity and Related Diseases
- Publisher
- Elsevier BV
- Published
- 2007-11
- Volume
- 3
- Issue
- 6
- Pages
- 597-601
- ISSN
- 1550-7289 (ISSN-L)
- PMC
- PMC2134840
- OpenAlex
- W2009224194
- Cited by
- 344
- References
- 26
- Citations by year
- 2026: 2 · 2025: 5 · 2024: 5 · 2023: 7 · 2022: 12 · 2021: 13 · 2020: 12 · 2019: 21 · 2018: 13 · 2017: 18 · 2016: 31 · 2015: 30 · 2014: 27 · 2013: 36 · 2012: 27
- FWCI
- 17.30
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Surgery for Obesity and Related Diseases (publishedVersion)
- PubMed (publishedVersion)
- Research at the University of Copenhagen (University of Copenhagen) (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK072011)
- National Center for Research Resources (UL1RR024156, RR 00645, M01RR000645)
- Topics
- Health Sciences › Medicine › Surgery › Bariatric Surgery and Outcomes
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
- Keywords
- Roux-en-Y gastric bypass, gastric banding
- MeSH terms
- Adult, Analysis of Variance, Cross-Sectional Studies, Female, Gastric Inhibitory Polypeptide, Glucagon, Humans, Middle Aged, Obesity, Morbid, Gastric Bypass, Gastroplasty, Postprandial Period, Glucagon-Like Peptide 1
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review